Empire Comfort Systems DVP36PP32EN-3 Series Installation Instructions And Owner's Manual

Empire Comfort Systems DVP36PP32EN-3 Series Installation Instructions And Owner's Manual

The direct vent zero clearance gas fireplace heater
Hide thumbs Also See for DVP36PP32EN-3 Series:

Advertisement

EMPIRE
EMPIRE
Comfort Systems
The Direct Vent Zero Clearance Gas
Fireplace Heater
Installer:
Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
WARNING: If the information in these instructions
are not followed exactly, a fire or explosion may
result causing property damage, personal injury
or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
WARNING: If not installed, operated and maintained
in accordance with the manufacturer's instructions,
this product could expose you to substances in fuel
or from fuel combustion which can cause death or
serious illness.
INSTALLATION INSTRUCTIONS
OWNER'S MANUAL
AND

DIRECT VENT

GAS FIREPLACE HEATER
MODEL SERIES
DVP36PP32EN-3
DVP36PP32EP-3
DVP36SP32EN-3
DVP36SP32EP-3
GAS-FIRED
UL FILE NO. MH30033
WARNING
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA only)
or mobile home, where not prohibited by state or local
codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified
kit is used.
HOT GLASS
WILL
CAUSE BURNS.
DO NOT TOUCH
GLASS
UNTIL COOLED.
NEVER
ALLOW CHILDREN
TO TOUCH GLASS.
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Empire Comfort Systems DVP36PP32EN-3 Series

  • Page 1: Direct Vent

    EMPIRE OWNER’S MANUAL Comfort Systems DIRECT VENT The Direct Vent Zero Clearance Gas Fireplace Heater GAS FIREPLACE HEATER MODEL SERIES DVP36PP32EN-3 DVP36PP32EP-3 DVP36SP32EN-3 DVP36SP32EP-3 GAS-FIRED Installer: Leave this manual with the appliance. UL FILE NO. MH30033 Consumer: Retain this manual for future reference.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Section Page Carton Contents ............................3 Hardware Package ............................3 Important Safety Information ........................4 Safety Information for Users of LP Gas ......................5 Requirements for Massachusetts ......................... 6 Introduction ..............................7 Specifications ............................... 8 Fireplace Dimensions ........................... 9 Clearances ..............................
  • Page 3: Carton Contents

    CARTON CONTENTS Additional Parts for Peninsula Models Only: Fireplace Assembly Canopy, End* Installation Package Canopy, Right* 3/8" x 12" Flexline Canopy, Left* Rockwool Packet End Shield* Installation Instructions Canopy Corner Tie* Serial Number Tag *Note: Installation required when using EMPT Recepticle, 3-Prong series Peninsula Mantel Warranty Card...
  • Page 4: Important Safety Information

    IMPORTANT SAFETY INFORMATION Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly. DO NOT OPERATE THIS APPLIANCE WITHOUT ALL GLASS DOOR PANELS INSTALLED • If this appliance is installed directly on carpeting, • Adequate accessibility clearances for servicing and tile or other combustible material other than wood proper operation.
  • Page 5: Safety Information For Users Of Lp Gas

    SAFETY INFORMATION FOR USERS OF LP GAS Propane (LP-Gas) is a flammable gas which can cause fires by point with the members of your household. Someday and explosions. In its natural state, propane is odorless and when there may not be a minute to lose, everyone’s safety colorless.
  • Page 6: Requirements For Massachusetts

    REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed SIGNAGE. A metal or plastic identification plate shall be in every dwelling, building or structure used in whole or in part for permanently mounted to the exterior of the building at a residential purposes, including those owned or operated by the minimum height of eight (8) feet above grade directly in line Commonwealth and where the side wall exhaust vent termination...
  • Page 7: Introduction

    Commonwealth of • Modification of the fireplace or direct vent system. Massachusetts. • Installation other than as instructed by Empire Comfort Systems, Inc. The installation must conform with local codes or, in the absence of •...
  • Page 8: Specifications

    SPECIFICATIONS DVP36(SP,PP) Nat Models Remote Control Description Input Btu/hr Maximum 35,000 Options & Accessories Btu/hr Minimum (millivolt only) 24,000 FRBC Millivolt Battery Remote ON/OFF KWH (Maximum) 10.15 FRBTC Millivolt Battery Remote T-Stat (Minimum) 6.96 FRBTP Millivolt Battery Remote with Thermostat Orifice Millivolt Wireless Wall Thermostat Air Shutter Opening...
  • Page 9: Fireplace Dimensions

    FIREPLACE DIMENSIONS HORIZONTAL VENT CONNECTION SEE THRU PENINSULA 31 7/8 17 ½ 32 ½ 32 ½ Figure 1 MODEL DVP36SP32E DVP36PP32E 34 3/4” 34 3/4” 39" 39" 24” 24” 22" 22" 36” 36” 29 1/4” 32 5/8” 22” 22” 41 1/8” 41 1/8”...
  • Page 10: Clearances

    CLEARANCES Clearance to Combustibles Air Drop (End) 1/2" (12.7 mm) Side 1/2" (12.7 mm) Floor 0" (0 mm) Top Stand-off 0" (0 mm) Top Framing Edge 6 3/8" (161.7 mm) SEE MANTLE CHART FOR MAXIMUM MANTLE DEPTH 42” 1 3/4” MIN. 2”...
  • Page 11: Optional Empt Series Mantel Installation - Peninsula Models Only

    OPTIONAL EMPT SERIES MANTEL INSTALLATION - PENINSULA MODELS ONLY The Peninsula Direct Vent fireplaces include a 3-Piece Canopy the Rear Mantel Corner Bracket. Align the holes in the canopy and End Shield. These additional parts must be installed on the with the corner bracket and loosely install a #10 x 1/2"...
  • Page 12: Locating Fireplace

    LOCATING FIREPLACE Note:** Island (C) and Room Divider (D) installation is possible as long as the horizontal portion of the vent system (H) does not exceed 20 feet with a minimum vertical run of 8 feet. See details in Venting Section. *When you install your Direct Vent Fireplace, a minimum of 1 3/4 inches clearance must be maintained from the perpendicular wall and the front opening of the appliance.
  • Page 13: Gas Supply

    GAS SUPPLY The gas pipeline can be brought in through the right or left side of Installing a New Main Gas Cock the appliance. Consult the current National Fuel Gas Code, ANSI Each appliance should have its own manual gas cock. Z223.1 CAN/CGA-B149 (.1 or .2) installation code.
  • Page 14: Rear Vent Conversion

    REAR VENT CONVERSION HORIZONTAL VENTING VERTICAL VENTING Note: It is recommended that the flue cover plate tab be pulled outward prior to removal. INLET VENT COVER PLATE INLET VENT COLLAR FLUE COVER PLATE This will ensure that the plate is not accidentally dropped FLUE OUTLET COLLAR inside the rear air chamber.
  • Page 15: Planning Installation

    PLANNING INSTALLATION If the fireplace is installed directly on carpeting, tile or other In planning the installation for the fireplace, it is necessary to combustible material other than wood flooring, it should be determine where the unit is to be installed and whether optional installed on a metal or wood panel extending the full width accessories are desired.
  • Page 16: Fireplace Installation Instructions

    FIREPLACE INSTALLATION INSTRUCTIONS (continued) Locating Fireplace . Attach the framing brackets to the fireplace, place fireplace in framed opening and secure to framing. Different hole locations can be used for finishing materials with thicknesses of 3/8", 1/2" and 3/4". Secure the brackets with screws provided using two (2) per framing bracket.
  • Page 17: Installation

    INSTALLATION Attention: Add 3-3/4" to “A” dimensions when using a flush mantel Flush Mount Mantel Installation - See-through Models Only base. (Figure 15) Attention: If a base or mantel is not used and the appliance is The fireplace must extend 3/4" beyond finished wall surface when installed directly on carpeting, tile or other combustible material using a flush mount mantel on see-through models.
  • Page 18 Combustible Surround Installation Vent Pipe Clearance Note: Maintain one inch (1") of clearance around vertical vent pipe. See Figure 18. For horizontal vent, maintain a minimum 1" clearance to the bottom and sides of the vent, and 3" clearance to combustibles above the vent pipe.
  • Page 19 INSTALLATION (continued) HORIZONTAL ONLY, STRAIGHT OUT THE BACK “A” PIPE LENGTH VENT CAP WALL FIRESTOP/ THIMBLE “B” "A" "B" 6" 5 1/8" to 6 1/2" 9" 8 1/8" to 9 1/2" 12" 11 1/8" to 12 1/2" Figure 20 VERTICAL, 90° ELBOW TO HORIZONTAL OUT THE WALL “A”...
  • Page 20: Venting Fireplace - Top

    VENTING FIREPLACE - TOP Venting Graph (Dimensions in Feet) To Use the Vent Graph (Figure 22) 1. Determine the height of the center of the horizontal vent pipe. Using this dimension on the Sidewall Vent Graph, locate the point it intersects with the slanted TOP EXIT - VERTICAL AND HORIZONTAL TERMINATION (DIMENSIONS IN FEET) graph line.
  • Page 21 VENTING FIREPLACE - TOP (continued) Below Grade Installation When it is not possible to meet the required vent terminal clearances of 12" (305mm) above grade level, a snorkel kit is recommended. See page 38. It allows installation depth down to 7" (178mm) below grade level.
  • Page 22 10” (254mm) VENT CAP 11” SEE VENT CHART (279mm) FOR PERMISSIBLE “H” AND “V” DIMENSIONS 1 FOOT VERTICAL PIPE REQUIRED (MINIMUM) 9” (229 MM) MINIMUM NOTE: 1 FOOT SECTION (MIN.) OF VERTICAL VENT REQUIRED WHEN USING HORIZONTAL CENTER OF ELBOW STRAIGHT OUT TERMINATION OFF TOP.
  • Page 23: Dvvk-4Fv Direct Vent Termination Kit

    DVVK-4FV DIRECT VENT TERMINATION KIT Installation Instructions This termination kit can only be used with Empire Comfort Systems direct vent fireplaces listed for use with DVVK-4FV Vertical Flex Vent Kit. Please review the instructions packaged with your fireplace and verify the fireplace model number.
  • Page 24 PRE-INSTALLATION INFORMATION: Items Required For Installation: Tools Building Supplies Phillips Screwdriver Framing Materials Hammer Wall Finishing Materials Saw and/or saber saw Caulking Material (Noncombustible) Level Support Strap supplies Measuring Tape Electric Drill and Bits Pliers Square Tin Snips Before You Start: Plan your installation.
  • Page 25 DVVK-4FV DIRECT VENT TERMINATION KIT (continued) Step-By-Step Installation For Flex DV Kit Unpack vent components and check all items for shipping Next, determine the location for the cutout in the roof opening. damage. This opening must be large enough to provide a minimum 1” For this venting system to operate as designed it is dependent air space clearance from the vertical vent pipe to any combus- on the use of all parts and procedures detailed in these in-...
  • Page 26 DVVK-4FV DIRECT VENT TERMINATION KIT (continued) 10. With the flex vent assembly and the 48” long hard pipe com- 13. Now the pre-assembled vent system may be carried to the ponents laid out on the floor, begin securing these parts to- roof, then lowered through the roof cutout opening (see step gether.
  • Page 27 DVVK-4FV DIRECT VENT TERMINATION KIT (continued) 17. To attach the vent connections at the fireplace, be sure the 7” 21. An additional storm collar band is provided in kit that may be diameter adapter collar has been installed per step 3. Apply a used as an attic insulation shield.
  • Page 28 DVVK-4FV DIRECT VENT TERMINATION KIT (continued) VERTICAL TERMINATION STORM COLLAR 4’ LONG RIGID PIPE ROOF FLASHING ADJUSTABLE ROOF JACK ASSEMBLY ROOF EXTERIOR CLEARANCE TO COMBUSTIBLES REQUIRED FROM VENT PIPE CLAMPS AT FLUE & INLET VENT CONNECTIONS ADJUSTABLE STORM COLLAR (USE TO FIRESTOP/THIMBLE KEEP INSULATION OUT OF ASSEMBLY...
  • Page 29: Dvvk-4Fv Direct Vent Termination Kit

    DVVK-4FV DIRECT VENT TERMINATION KIT (continued) Vertical Flex Termination Kit Item Quantity Number Item Description Repair Part No. Supplied 4”/7” Vertical Termination Cap MF100038 Roof Support Kit MF100503 2 Ply Alum Flex 4” Diameter by 6 ft. MF04ALA2F006 2 Ply Alum Flex 7” Diameter by 6 ft. MF07ALA2F006 4”/7”...
  • Page 30: Examples - Top Vent Run

    EXAMPLES - TOP VENT RUN 24” 24” MINIMUM CLEARANCE TO COMBUSTIBLES Example H2 3ft, H3 1ft = 4ft (90° + 90° + 90°) = 6ft V1 = 21ft H = 10ft V = 21ft Figure 37 Example H2 = 2ft 2 - (90°...
  • Page 31: Venting Fireplace - Rear

    VENTING FIREPLACE - REAR Venting Graph (Dimensions in Feet) To Use the Vent Graph (Figure 39) 1. Determine the height of the center of the REAR EXIT - VERTICAL AND HORIZONTAL TERMINATION horizontal vent pipe. Using this dimension on the (DIMENSIONS IN FEET) Sidewall Vent Graph, locate the point it intersects with the slanted graph line.
  • Page 32: Examples - Rear Vent Run

    EXAMPLES - REAR VENT RUN Model Maximum Pipe Length H1 DVP36(SP,PP) 18" H1 = 18” MAX. Figure 42 Figure 40 Model Maximum Pipe Length H1 DVP36(SP,PP) 18" Figure 43 H1 = 18 inches max Figure 41 Page 32 30786-3-0614...
  • Page 33: Termination Clearances

    TERMINATION CLEARANCES Termination clearance for buildings with combustible and noncombustible exteriors. Figure 44 Vertical Sidewall Installations Important! Minimum clearance between vent pipes and combustible materials is three (3") (76mm) on top, and (1") (25mm) on bottom and sides. Important! When vent termination exits through foundation less than 20" below siding outcrop, the vent pipe must extend outward so that the horizontal vent terminal is located flush to, or beyond the outcrop siding.
  • Page 34: Vent Clearances

    VENT CLEARANCES Figure 45 *Clearance above grade, veranda, porch, deck or balcony clearance to non-mechanical air supply inlet to building or [*12 inches (30cm) minimum] the combustion air inlet to any other appliance [*12 inches (30cm) minimum for appliances ≤ 100,000 Btuh (30 kW) clearance to window or door that may be opened [*12 inches (30cm) minimum for appliances <...
  • Page 35: Vent System Identification

    45° ELBOW ROOF FLASHING TWO 90° ELBOWS) 90° ELBOW Special venting components (Simpson Duravent) See Empire Comfort Systems Retail Price List for Simpson Duravent part numbers and pricing. CEILING FIRESTOP Special DV Vent Kits WALL STRAP Available from Empire Comfort Systems, Inc. dealers.
  • Page 36: Framing And Finishing

    FRAMING AND FINISHING Installing Support Brackets (Figure 47) A horizontal pipe support MUST BE used for each 3 feet of horizontal run. The pipe supports should be placed around the pipe and nailed in place to framing members. There MUST BE a 3 inch clearance to combustibles above 6 5/8 inch diameter pipe and elbows and 1 inch clearance on both sides and bottom of 6 5/8 inch pipe to 10”...
  • Page 37: Framing And Finishing

    FRAMING AND FINISHING (continued) Figure 49 Figure 51 Figure 50 30786-3-0614 Page 37...
  • Page 38: Horizontal Termination

    HORIZONTAL TERMINATION NOTE: Termination cap should pass through the wall firestop from the exterior of the building. Adjust the termination cap to its final exterior position on the building. SNORKEL WARNING: Termination cap must be positioned so that arrow is pointing up. Attach the termination cap with the four wood screws provided.
  • Page 39: Dvvk-4Re Vent Kit Installation Instructions

    DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS CAUTION: Sharp edges, use protective gloves when NOTE: SPACING FLANGE installing. INSTALLED TO TOPSIDE Tools Needed for Installation: Sheet metal snips 5/16” nut driver Phillips head screwdriver - #2 High temperature sealant or furnace cement rated for continuous use at 1,000 F minimum Measuring tape...
  • Page 40 DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (continued) 8. Attach the 4” (102mm) diameter flue outlet tube onto the rigid venting system or directly to fireplace. Ensure the 4” (102mm) VINYL SIDING KIT DV822 diameter flue outlet tube is placed as far as possible onto the rigid venting system.
  • Page 41 DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (continued) Follow correct option according to venting method. Connecting to Rigid Vent System If the air inlet and flue outlet tubes are to be connected to a rigid Connecting Directly to Fireplace venting system (and not directly to the back of the unit), then do If the air inlet and flue outlet tubes are to be connected directly to not use the gasket provided.
  • Page 42: Dvvk-4F Flex Vent Instructions

    DVVK-4F FLEX VENT INSTRUCTIONS The DVVK-4F FLEX VENT KIT includes the following compo- Install the Wall Firestop/Thimble assembly as required through the wall. Refer to the venting charts in the fireplace manual to determine nents: the proper height and size of the vent opening. The minimum opening •...
  • Page 43: Vertical Termination

    VERTICAL TERMINATION Locate and mark the center point of the venting pipe. Using a nail When terminating the vent cap near an exterior wall or overhang, on the underside of the roof and drive this nail through this center maintain minimum clearances as shown in Figure 60. point.
  • Page 44 VERTICAL TERMINATION (continued) NOTE: When installing this vent system in a chase, it is always good Vertical Through the Roof Applications (Figure 62) building practice to insulate the chase as you would the outside Your Gas Fireplace has been approved for: walls of your home.
  • Page 45: Placement Of Glowing Embers

    PLACEMENT OF GLOWING EMBERS Placement of the glowing embers (rockwool) is very individual and light coverage of the areas indicated will provide your best effects. We recommend separation of the rockwool by hand and to make your coverage as light and fluffy as possible. Place just enough embers on the burner to obtain the glow and a gold yellow flame.
  • Page 46: Operation Instructions/Flame Appearance

    OPERATION INSTRUCTIONS/FLAME APPEARANCE Before you begin: Do not handle the logs with your bare hands! The initial break-in operation should be 5 to 10 minutes on (at the Always wear gloves to prevent skin irritation. After handling logs, highest setting) then let cool for 10 to 15 minutes. Repeat this On/ wash your hands gently with soap and water.
  • Page 47: Operating Instructions

    OPERATING INSTRUCTIONS 750 Millivolt System the fireplace will light and operate satisfactorily. The standing pilot (750 millivolt system) is a continuous burning pilot. Subsequent lightings of the appliance will not require such purging The pilot remains ON even when the main burner is OFF. if the gas valve is not turned to “OFF.”...
  • Page 48: Operating Instructions

    If damage occurs to the combustion chamber, it must be replaced bare, will attach to one of the accessories that can be purchased by a qualified service person. Contact Empire Comfort Systems, for use with your fireplace. Inc. for replacement parts.
  • Page 49: Standing Pilot Wiring Diagram

    STANDING PILOT WIRING DIAGRAM (OPTIONAL) THERMOSTAT (OPTIONAL) WALL SWITCH Figure 66 30786-3-0614 Page 49...
  • Page 50: Standing Pilot Lighting Instructions

    STANDING PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When •...
  • Page 51: Standing Pilot Troubleshooting

    STANDING PILOT TROUBLESHOOTING With proper installation and maintenance, your new Direct Vent Gas Fireplace will provide years of trouble-free service. If you do experience a problem, refer to the Trouble Shooting Guide below. This guide will assist a qualified service person in the diagnosis of problems and the corrective action to be taken. 1.
  • Page 52: Maintenance And Service

    MAINTENANCE AND SERVICE WARNING: Do not use abrasive cleaners on glass. Do not PLEASE NOTE attempt to clean glass when glass is hot. It is normal for appliances fabricated of steel to give off some expansion and/or contraction noise during the start Glass Removal and Replacement (Figure 67) up or cool down cycle.
  • Page 53: Parts List

    PARTS LIST PART NO. PART NO. INDEX INDEX DESCRIPTION DESCRIPTION DVP36SP DVP36PP DVP36SP DVP36PP MALE 5/16 X 3/8 NPT 24316 24316 FIREPLACE ASSEMBLY R2423 R2423 CONNECTOR UPPER LOUVER 18807 18807 R7577 R7577 VALVE - NAT ASSEMBLY R7578 R7578 VALVE - LP GLASS FRAME 24307 24307...
  • Page 54: Dvp36Sp Parts View

    DVP36SP PARTS VIEW Page 54 30786-3-0614...
  • Page 55: Dvp36Pp Parts View

    DVP36PP PARTS VIEW 30786-3-0614 Page 55...
  • Page 56: Wiring Instructions For Installing A Dual Switch / Receptacle

    WIRING INSTRUCTIONS FOR INSTALLING A DUAL SWITCH / RECEPTACLE CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED In order to install both the optional Blower and Accent Light acces- sories, it will be necessary to install the junction box so that the ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL Duplex Receptacle wiring is split.
  • Page 57: Accent Lamp

    ACCENT LAMP Your Direct Vent Gas Fireplace comes equipped with an "Accent COVER Lamp." The light has been pre-wired and is controlled from the Rheostat. If in the event the lamp or lens needs to be replaced, follow the instructions below: Unplug the Accent Lamp from the junction box inside the fireplace.
  • Page 58: Optional Fbb5 Blower Installation Instructions

    OPTIONAL FBB5 BLOWER INSTALLATION INSTRUCTIONS To install the blower kit or access the junction box, remove lower Attention: Install blower assembly before connecting gas in- louver as illustrated by figure 71. let supply line. A factory included junction box is located in the lower compartment Wiring of the fireplace.
  • Page 59 OPTIONAL BLOWER INSTALLATION INSTRUCTIONS (continued) 10. Replace louver(s). Insert blower assembly into interior, bottom of fireplace. 11. This completes the installation of the optional FBB5 Blower kit Note: On peninsula models, the blower must be installed at accessory. the end which has the brick panel installed. Position blower assembly so that you align the notch on back of blower as- Note: This blower is equipped with a heat activated fan control sembly with the center screw on side/end panel, then push...
  • Page 60 OPTIONAL BLOWER INSTALLATION INSTRUCTIONS (continued) Blower Motor Wiring The blower motor does not have oiling holes. Do not attempt to oil The appliance, when installed, must be electrically grounded in the blower motor. accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, if an external electrical Blower Wheels source is utilized.
  • Page 61: Accessories

    ACCESSORIES The following accessory parts can be obtained from your Empire Comfort Systems dealer. If you need additional information beyond what your dealer can furnish, contact Empire Comfort Systems Inc., Nine Eighteen Freeburg Ave., Belleville, Illinois 62220-2623. Accessory Description Model Numbers Fan Kit Designed to provide forced air flow.
  • Page 62: Master Parts Distributor List

    This list changes from time to time. For the current list, please click on the Master Parts button at www.empirecomfort.com. Please note: Master Parts Distributors are independent businesses that stock the most commonly ordered Original Equipment repair parts for Heaters, Grills, and Fireplaces manufactured by Empire Comfort Systems Inc. Dey Distributing Victor Division of F.
  • Page 63: Warranty

    WARRANTY Empire Comfort Systems Inc. warranties this hearth product to be free from defects at the time of purchase and for the periods speci- fied below. Hearth products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the instructions in the owner’s manual.
  • Page 64 Empire Comfort Systems Inc. EMPIRE EMPIRE 918 Freeburg Ave. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. Comfort Systems www.empirecomfort.com...

Table of Contents