Easy Menu Button
i-THINK Controller
i-THINK
5 LED-red light
Controller
Flashes
Flashes
To reset - Press the Selector
Button and the Yes / No
mode will appear. While
flashing turn the Button to
toggle between Yes and No.
Select Yes and press the
Selector Button to select.
16
© Baxi Heating UK Ltd 2011
Menu
20:Boiler sensor 1
Button
Selector Button
04. November
Tuesday
Reset Type
Auto
User
Service
On
164:Flow press switch HC
157: Boiler flow thermostat
Reset ?
157: Boiler flow thermostat
Reset ?
266:Fan Fault

9.0 Resetting the Boiler

9.1
1. In exceptional cases, the display will show an error screen see
Error
diagram opposite.
2. With the following information: -
2008
08:50
3. Pressing the menu button will return the i-THINK Controller
to the standard display which will now show the following
symbol -
in the appliance. After 1 minute the display will automatically
revert to the error screen.
4. Press the menu button twice to revert to the error display
immediately. A list of error codes is shown in section 11.1. This
list contains both user reset and automatic reset codes.
Automatic codes are given here as they are capable of clearing
automatically and do not necessarily indicate that a service visit is
required.
9.2
1. If a flashing spanner is shown on the i-THINK Controller the
error may reset once the condition has cleared. Many of these
automatic reset errors are connected with temperature sensors
of both the system and the appliance and once the appliance has
cooled it may restart. If the problem persists where the same
error code is repeatedly displayed or the error will not clear you
Error
should call for a service engineer.
9.3
1. A user reset can only be carried out on the i-THINK
Controller when it is not a Room Sensor.
2. To perform a user reset:-
a) on the 5 LED Receiver, press the reset button at the bottom
Error
of the unit, after a few seconds the red flashing LED will go out.
b) on the i-THINK Controller reset appears, press the Selector
Button twice, after a few seconds the error symbol should
disappear.
3. The error will clear and the appliance will restart if there is a
demand for heat as long as the error condition has cleared. The
Error
user error codes give an indication of possible problems which
Yes
the user may be able to rectify such as accidental isolation of
either the gas supply (error 261and 262) or the central heating
circuit, pump problems etc (error 275 and 276).
4. If the error returns the fault condition is still present.
9.4
When a flashing spanner is accompanied by a crossed out flame
Error
symbol on the appliance, a fault has occurred which requires the
presence of a service engineer. When ringing the Heateam
Service Department to request a service engineer please quote
the error code and accompanying message.
Exceptional conditions
An error number
a short description of the error
The display may or may not show a flashing spanner, a
flame crossed out or both depending on whether the unit
is on the appliance or the wall.
E
which indicates that an error or fault has occurred
Automatic reset
User reset
Service reset