C O N T E N T S INTRODUCTION ........................... 4 SAFETY ..............................5 III. YOUR POWER CHAIR ........................18 IV. ASSEMBLY ............................22 COMFORT ADJUSTMENTS ......................23 VI. BATTERIES AND CHARGING ...................... 28 VII. CARE AND MAINTENANCE ......................32 APPENDIX I - SPECIFICATIONS ......................
I . I N T R O D U C T I O N SAFETY WELCOME to Quantum Rehab, a division of Pride Mobility Products Corporation (Pride). The power chair you have purchased combines state-of-the-art components with safety, comfort, and styling in mind. We are confident that these design features will provide you with the conveniences you expect during your daily activities.
Page 5
I I . S A F E T Y PRODUCT SAFETY SYMBOLS The symbols below are used on the power chair to identify warnings, mandatory actions, and prohibited actions. It is very important for you to read and understand them completely. Read and follow the information in the owner’s manual.
I I . S A F E T Y Pinch/Crush points created during assembly. Do not remove anti-tip wheels. Do not connect an extension cord to the AC/DC converter or the battery charger. Removal of grounding prong can create electrical hazard. If necessary, properly install an approved 3-pronged adapter to an electrical outlet having 2-pronged plug access.
Page 7
I I . S A F E T Y EMI-RFI - This product has been tested and passed at an immunity level of 20 V/m. Explosive conditions exist! Use only AGM or Gel-Cell batteries to reduce the risk of leakage or explosive conditions. Keep tools and other metal objects away from battery terminals.
Page 8
I I . S A F E T Y Battery charger for indoor use only. Disposal and recycling — Contact your Quantum Rehab Provider for information on proper disposal and recycling of your Pride product and its packaging. Locked and in drive mode. Place unit on level ground and stand to one side when changing from drive mode to freewheel mode or freewheel mode to drive mode.
Page 9
I I . S A F E T Y Contains Lead. No step. No standing. Keep off! Quantum R-4000 www.pridemobility.com...
I I . S A F E T Y GENERAL GUIDELINES MANDATORY! Do not operate your new power chair for the first time without completely reading and understanding this owner’s manual. Your power chair is a state-of-the-art life-enhancement device designed to increase mobility. Pride provides an extensive variety of products to best fit the individual needs of the power chair user.
I I . S A F E T Y Weight Limitations Your power chair is rated for a maximum weight capacity. Please refer to the specifications table for this limit. Keep in mind that the maximum weight capacty includes the combined weight of the user and any accessories mounted to the power chair.
Page 12
I I . S A F E T Y WARNING! Never travel down an incline backward. Doing so may cause the powerchair to tip. Always exercise extreme caution when negotiating an incline. WARNING! If your power chair is equipped with a reclining seatback, do not attempt to negotiate inclines with the seat in a reclined position.
Page 13
I I . S A F E T Y WARNING! When cornering sharply, reduce your speed and maintain a stable center of gravity. This greatly reduces the possibility of a tip or fall. Public Streets and Roadways WARNING! You should not operate your power chair on public streets and roadways. Be aware that it may be difficult for traffic to see you when you are seated on your power chair.
I I . S A F E T Y Figure 2. Correct Curb Approach Figure 3. Incorrect Curb Approach WARNING! Even though your power chair may be capable of handling greater obstacles, Pride recommends that you do not attempt to negotiate a curb that has a height greater than 2 in. (5 cm).
I I . S A F E T Y Motor Vehicle Transport Pride recommends that you do not remain seated in your power chair while traveling in a motor vehicle. The power chair should be stowed in the trunk of a car or in the back of a truck or van with batteries removed and properly secured.
Page 16
I I . S A F E T Y Transfers Transferring onto and off of your power chair requires a good sense of balance. Always have an attendant or healthcare professional present while learning to prop- erly transfer yourself. To eliminate the possibility of injury, Pride recom- mends that you or a trained attendant perform the fol- lowing tasks before attempting a transfer: Turn off the power to the controller.
Page 17
I I . S A F E T Y Reaching and Bending Never reach, lean, or bend while driving your power chair. If it is absolutely necessary to reach, lean, or bend while seated on your power chair, it is important to maintain a stable center of gravity and keep the power chair from tipping.
Page 18
I I I . Y O U R P O W E R C H A I R THE QUANTUM R-4000 SERIES POWER CHAIR Your power chair has two main assemblies: the seat and the power base. See figures 5 and 6. Typically, the seat assembly includes the armrests, seatback, and seat base.
I I I . Y O U R P O W E R C H A I R CONTROLLER CONNECTOR FRONT TRAPEZE BAR FRONT SHROUD MANUAL FREEWHEEL LEVER MAIN CIRCUIT BREAKER MOTOR/BRAKE ASSEMBLY Figure 6. The Quantum R-4000 Power Base BATTERY DOOR LATCH LOCATION CONTROLLER HARNESS ANTI-TIP WHEEL...
Page 20
I I I . Y O U R P O W E R C H A I R Electrical Components The electrical components are located on the front of the power base or on the battery door at the rear of the power base depending on the power chair electrical system.
Page 21
I I I . Y O U R P O W E R C H A I R Figure 8. Freewheel Mode (Drive Disengaged) - Hammer Figure 9. Drive Mode (Drive Engaged) - Hammer Motor Motor Figure 11. Drive Mode (Drive Engaged) - Glide Motor Figure 10.
I V . A S S E M B L Y Seat Installation It may be necessary to install the seat either prior to initial operation or after transporting your power chair. NOTE: If your power chair is equipped with a Specialty Seat, Synergy Seat, or a Synergy TRU-Balance 2 Power Positioning System, refer to the information provided in separate manuals.
Your Quantum Rehab Provider has evaluated your power chair and made any necessary adjustments to suit your specific requirements. Do not change your seating configuration without first contacting Pride Mobility Products or your Quantum Rehab Provider.
V . C O M F O R T A D J U S T M E N T S 10. Loosen the shroud fasteners and remove the front shroud from the power base. 11. Remove the hardware from the front trapeze bar. 12.
V . C O M F O R T A D J U S T M E N T S Seatback Angle Adjustment If your power chair is equipped with an adjustable seatback, you can adjust it to four (4) different angles: JAM NUT 90°, 102°, 105°, or 107°.
V . C O M F O R T A D J U S T M E N T S Controller Position You can move the controller in toward or out away from the armrest, or change the position of the control- ler for either left-hand or right-hand use.
Page 27
V . C O M F O R T A D J U S T M E N T S Anti-Tip Wheels The anti-tip wheels are designed to give your power chair increased stability on rough surfaces. The anti-tip wheels are preset at the factory for smooth surfaces or indoor use only.
V I . B A T T E R I E S A N D C H A R G I N G BATTERIES AND CHARGING The Quantum R-4000 uses two long-lasting, 12-volt, deep-cycle batteries. These batteries are sealed and mainte- nance free.
V I . B A T T E R I E S A N D C H A R G I N G To charge the batteries using the off-board charger: 1. Position the front of your power chair next to a standard electrical outlet.
Page 30
V I . B A T T E R I E S A N D C H A R G I N G How often must I charge the batteries? Many factors come into play when deciding how often to charge the batteries. You may use your power chair all day on a daily basis or you may not use it for weeks at a time.
Page 31
V I . B A T T E R I E S A N D C H A R G I N G How can I ensure maximum battery life? A fully charged deep-cycle battery will provide reliable performance and extended battery life. Keep your power chair’s batteries fully charged whenever possible.
V I I . C A R E A N D M A I N T E N A N C E CARE AND MAINTENANCE Your Quantum R-4000 is a sophisticated power chair. Like any motorized vehicle, it requires routine maintenance checks.
V I I . C A R E A N D M A I N T E N A N C E All wheel bearings are prelubricated and sealed. They require no subsequent lubrication. The body shroud has been sprayed with a clear sealant coating. You can apply a light coat of car wax to help it retain its high-gloss appearance.
V I I . C A R E A N D M A I N T E N A N C E Storage Your power chair should be stored in a dry place, free from temperature extremes. When storing, disconnect the batteries from the power chair.
V I I . C A R E A N D M A I N T E N A N C E TIRE TUBE SCREWS FRONT RIM HALF WHEEL HUB REAR RIM HALF LUG NUT Figure 23. Quantum R-4000 Drive Wheel Figure 24.
V I I . C A R E A N D M A I N T E N A N C E To replace the batteries: 1. Turn off the power to the controller. 2. Push the manual freewheel lever in or up for drive mode. 3.
A P P E N D I X I - S P E C I F I C A T I O N S SPECIFICATIONS Suspension: Full suspension - Sport Trac Drive Wheels: 14 in. (35.5 cm), center-mounted, pneumatic or solid available Caster Wheels: 9 in.
Page 38
A P P E N D I X I - S P E C I F I C A T I O N S LENGTH (WITHOUT FRONT RIGGINGS) 33 in. (83.82 cm) 23.5 in. (59.69 cm) WIDTH 25.375 in. (64.45 cm) TURNING RADIUS (WITHOUT FRONT RIGGINGS) GROUND CLEARANCE...
Page 39
N O T E S Quantum R-4000 www.pridemobility.com...
Page 40
N O T E S www.pridemobility.com Quantum R-4000...
Page 41
N O T E S Quantum R-4000 www.pridemobility.com...
Page 42
N O T E S www.pridemobility.com Quantum R-4000...
Page 43
Quality Control - Quantum R-4000 Series Inclusion of all Parts Joystick Serial Number Controller Serial Number Left Motor Serial Number Right Motor Serial Number Fit and Finish Performance Pride keeps a more detailed report on file at the factory. Date Inspected Inspector *INFMANU3576* Product Serial Number...