Tud100C972K; Tud120C954K; Tud120C960K; Tud140C960K - Trane XR80 Manual

Upflow/horizontal right or upflow/horizontal left induced draft gas furnace
Table of Contents

Advertisement

MODEL
TYPE
RATINGS 2
Input BTUH
Capacity BTUH (ICS) 3
AFUE
Temp. rise (Min.-Max.) °F.
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
See Fan Performance Table
Motor HP
R.P.M.
Volts / Ph / Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGER
Type -Fired
-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
GAS VALVE
Redundant - Single Stage
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz 4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs)
1 Central Furnace heating designs are certified by AGA and CSA.
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications,
above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
22-1640-06-0702 (EN)
General
Data
Product Specifications 1

TUD100C972K

Upflow / Horizontal
Upflow / Horizontal
100,000
80000
80.0
30 - 60
DIRECT
11 x 10
1
4
See Fan Performance Table
3/4
1100
115/1/60
Centrifugal
Direct - 1
1/50 - 3000
115/1/60
1.0
Yes
High Velocity
1 - 24x25 - 1in.
4 Round
Aluminized Steel - Type I
Aluminized Steel - Type I
20
5 — 45
5 — 56
Redundant - Single Stage
Hot Surface Ignition
Hot Surface Ignition
Multi-port In-shot
5
115/1/60
13.1
15
1/2
H x W x D
41-3/4 x 26-1/2 x 30-1/2
41-3/4 x 23 x 30-1/2
175 / 163

TUD120C954K

TUD120C960K

Upflow / Horizontal
120,000
96,000
80.0
35 - 65
DIRECT
11 x 10
1
4
See Fan Performance Table
1/2
1075
115/1/60
Centrifugal
Centrifugal
Direct - 1
1/50 - 3000
1/50 - 3000
115/1/60
1.0
Yes
High Velocity
High Velocity
1 - 20x25 - 1in.
1 - 24x25 - 1in.
4 Round
Aluminized Steel - Type I
20
6 — 45
6 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot
Multi-port In-shot
6
115/1/60
12.8
15
1/2
H x W x D
H x W x D
41-3/4 x 26-1/2 x 30-1/2
176 / 164
186 / 174
9

TUD140C960K

Upflow / Horizontal
120,000
140,000
96,000
111,000
80.0
80.0
30 - 60
40 - 70
DIRECT
DIRECT
11 x 10
11 x 10
1
4
See Fan Performance Table
1/2
3/4
1075
1075
115/1/60
115/1/60
Centrifugal
Direct - 1
Direct - 1
1/50 - 3000
115/1/60
115/1/60
1.0
1.0
Yes
Yes
High Velocity
1 - 24x25 - 1in.
4 Round
4 Round
Aluminized Steel - Type I
20
20
6 — 45
7 — 45
6 — 56
7 — 56
Redundant - Single Stage
Hot Surface Ignition
Multi-port In-shot
6
115/1/60
115/1/60
12.8
13.1
15
15
1/2
1/2
H x W x D
41-3/4 x 26-1/2 x 30-1/2
193 / 181
1
4
7

Hide quick links: