HumidiPRO™ Digital Humidity Control
H6062A1000

Specifications

Part Number:
Supply Voltage:
Amps:
Dimensions (See Fig. 1):
Width:
3.4 in.
Height:
1.27 in.
Length:
4.5 in.
Weight:
0.5 lbs
Shipping Dimensions:
Width:
4.05 in.
Height:
2.55 in.
Length:
5.88 in.
Weight:
0.67 lbs
Humidity Ranges:
Humidify Control Range:
• 20 - 60 % (Automatic mode)
• 10 - 90 % (Manual mode)
Dehumidify Control Range:
• 40 - 80 % (Automatic mode)
• 10 - 90 % (Manual mode)
Operating Ambient Temperature
• 32 to 120 °F (0 to 48.9 °C)
Operating Relative Humidity
• 5 to 95 %, non-condensing
Relative Humidity Accuracy:
For more information call 1-800-468-1502 or visit our
website at customer.honeywell.com.
Application and Benefits
HumidiPRO offers homeowners convenience and control with
automatic and manual control options as well as optional
advanced features such as expandable range stops and
dehumidification.
HumidiPRO automatically adjusts humidity to protect
windows from condensation in cold weather and can shut off
humidification based on a preset outdoor high temperature limit
(up to 90
). The homeowner can set HumidiPRO once at the
°F
beginning of a season and forget it. If needed, the homeowner
can use the humidity boost feature to temporarily raise the
humidity by 5% or 10%.
Job Name
Engineer
Mechanical Contractor
Contractor's P.O. No.
Representative
Notes
H6062A1000
18 to 30 VAC (50/60 Hz)
0.1 A, 2 VA
+/- 5 % RH
4-1/2 (114)
Fig. 1. Dimensions in inches (mm).
Honeywell HumidPRO
TM
The table below shows the levels of humidity HumidiPRO delivers
based on the outdoor temperature and window protection settings.
-10°F
0°F
1
10
10
10
10
2
10
10
10
10
3
10
14
10
14
4
15
19
15
19
5
21
26
21
26
6
29
34
29
34
7
35
35
39
46
8*
35
35
56
60
9
35
35
60
60
10
35
35
60
60
*Black Numbers show highest humidity allowed when Default RH% (35%) is Selected.
Note: Smaller grey numbers show highest humidity allowed when Maximum RH% (60%) is
selected.
Model(s)
Qty.
H6062A1000
Approval
Service
Tag. No.
SPECIFICATION DATA
1-17/64
(33)
1-17/64
3-13/32
(86)
Frost Index
Outdoor Temp
10°F
20°F
30°F
11
17
25
11
17
15
21
29
15
21
19
26
34
19
26
25
32
35
25
32
32
35
35
32
38
35
35
35
39
48
35
35
35
52
58
35
35
35
60
60
35
35
35
60
60
35
35
35
60
60
(32)
M34947
40°F
35
25
36
35
29
39
35
34
46
35
39
52
35
48
58
35
56
60
35
60
60
35
60
60
35
60
60
35
60
60
33-00003-01

Advertisement

loading

Summary of Contents for Honeywell HumidiPRO

  • Page 1: Specifications

    Operating Ambient Temperature Honeywell HumidPRO Frost Index • 32 to 120 °F (0 to 48.9 °C) The table below shows the levels of humidity HumidiPRO delivers Operating Relative Humidity • 5 to 95 %, non-condensing based on the outdoor temperature and window protection settings.
  • Page 2 Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 ® U.S. Registered Trademark. http://customer.honeywell.com © 2013 Honeywell International Inc. 33-00003—01 M.S. 07-13 Printed in U.S.A.

This manual is also suitable for:

Humidipro h6062a1000