Honeywell T87F Installation Instructions

Honeywell universal thermostat installation instructions.
Hide thumbs
   
T87F
TRADELINE
Universal Thermostat
Installation Instructions for the Trained Service Technician.
Application
CAUTION
1. Disconnect power supply to prevent electri-
The T87F Universal Thermostat provides tempera-
cal shock or equipment damage.
ture control for 24 to 30 Vac residential heating, cooling
2. To prevent interference with the thermostat
or heating-cooling systems. For heating systems, the
linkage, keep wire length to a minimum and
T87F mounts on the wallplate provided. For cooling
run wires as close as possible to the subbase.
only, or heating-cooling, order the 137421A (198170A
3. Do not overtighten thermostat captive mount-
if textured designer model) Heating-Cooling Wallplate
ing screws because damage to subbase threads
with remote switching, or the Q539 Subbase, which
can result.
provides switching at the thermostat location.
4. Do not short across coil terminals on relay.
The spdt switch makes one set of contacts on a tem-
This can burn out the thermostat heat antici-
perature fall to operate the heating system. The other set
pator.
of contacts make on a temperature rise to operate the
cooling system when the T87F is used to control cool-
IMPORTANT: An incorrectly leveled thermostat will
ing.
cause the temperature control to deviate from set
Heat anticipation is adjustable, 0.1 to 1.2A.
point.
LOCATION
Mercury Notice
Install the thermostat about 5 ft [1.5m] above the
M3375
floor in an area with good air circulation at average
This control contains mercury in a sealed tube. Do not
temperature.
place control in the trash at the end of its useful life.
Do not install the thermostat where it may be affected
If this control is replacing a control that contains
by:
mercury in a sealed tube, do not place your old control in
— drafts, or dead spots behind doors and in corners.
the trash.
— hot or cold air from ducts.
Contact your local waste management authority for
— radiant heat from sun or appliances.
instructions regarding recycling and the proper disposal
— concealed pipes and chimneys.
of this control, or of an old control containing mercury in
— unheated (uncooled) areas such as an outside wall
a sealed tube.
behind the thermostat.
If you have questions, call Honeywell Inc. at 1-
This thermostat is a precision instrument and was
800-468-1502.
carefully adjusted at the factory. Handle it carefully.
MOUNTING WALLPLATE OR SUBBASE (Fig. 2)
Installation and Setting
IMPORTANT:
1. Use a spirit level to accurately level the wallplate
WHEN INSTALLING THIS PRODUCT...
or subbase as in Fig. 1. Inaccurate leveling may
1. Read these instructions carefully. Failure to fol-
cause thermostat control deviation.
low them could cause a hazardous condition.
2. When using the T87F with a Q539 Subbase, follow
2. Check the ratings given in the instructions and on
the mounting and wiring instructions included with
the product to make sure the product is suitable for your
the subbase.
application.
3. Installer must be a trained, experienced service
1. Place the wallplate on the wall at the desired loca-
technician.
tion. Pull the thermostat cable through the entrance hole.
4. After installation is complete, check out product
2. Fasten wallplate. Do not tighten the screws.
operation as provided in these instructions.
3. Level according to Fig. 1 then tighten screws.
4. After wiring wallplate, plug hole to prevent drafts
from affecting thermostat.
NOTE: To mount T87 Thermostat on an outlet box,
order 129044A Adapter Ring Assembly.
®U.S. Registered Trademark
Copyright © 2002 Honeywell •
• All Rights Reserved
60-0830-4

   Related Manuals for Honeywell T87F

   Summary of Contents for Honeywell T87F

  • Page 1

    The spdt switch makes one set of contacts on a tem- perature fall to operate the heating system. The other set of contacts make on a temperature rise to operate the cooling system when the T87F is used to control cool- ing. Heat anticipation is adjustable, 0.1 to 1.2A.

  • Page 2

    Disconnect power supply before con- necting wiring to prevent electrical shock or equipment damage. The T87F is adaptable to most 2-wire, 24 to 30 volt heating systems, and to most 3-wire, 24 to 30 volt heating systems controlled by a Series 10 Thermostat.

  • Page 3

    (fewer cycles per hour) may be desirable for some systems. (HOT) RECALIBRATION The T87F is calibrated at the factory and no recali- bration should be necessary. If the thermostat is accu- rately leveled and still appears to be out of calibration, order 104994A Calibration Wrench. Instructions for recalibrat-ing are furnished with the wrench.