This manual describes the installation and operation of the Model WR2500X02 non-
catalytic wood heater. This heater meets US Environmental Protection Agency emis-
sion limits for wood heaters. Under specific conditions this heater has been shown to
5129
deliver heat at rates ranging from 9,500 to 57,800 BTU/hr.
WR2500X02 cover
SAfEty notICE
Read this entire manual before you install
and use your fireplace insert. If not properly
installed, a house fire may result. to reduce
the risk of fire, follow the installation instruc-
tions. failure to follow instructions may re-
sult in property damage, bodily injury or even
death. Contact local building, fire officials or
authorities having jurisdiction about permits,
restrictions and installation inspection re-
quirements in your area.
this unit is not mobile home approved.
This stove is listed by OMNI-Test Laboratories of Port-
land, Oregon to meet UL1482 for the US and ULC-S628
for Canada.
Do not Discard this Manual: Retain for future Use
Windsor EPA Certified
High Efficiency Wood
Insert
Model WR2500X02
owner's Manual
this appliance is manufactured for a 6"
(152 mm) Dia. chimney connection. (Refer
to Page 7)
30005129 3/10 Rev. 1

Advertisement

Table of Contents
loading

Summary of Contents for Pro Video WR2500X02

  • Page 1 Model WR2500X02 owner’s Manual This manual describes the installation and operation of the Model WR2500X02 non- catalytic wood heater. This heater meets US Environmental Protection Agency emis- sion limits for wood heaters. Under specific conditions this heater has been shown to 5129 deliver heat at rates ranging from 9,500 to 57,800 BTU/hr.
  • Page 2: About Your Appliance

    Windsor High Efficiency Wood Insert Why the correct chimney size is important CAUtIon Your appliance operates best using a minimum 6” (152 After reading these instructions, if you have any doubt mm) diameter chimney. The maximum chimney diam- about your ability to complete your installation in a eter must not exceed 10”...
  • Page 3: Specifications

    Under specific conditions this heater has been shown to deliver heat at rates ranging from 9,500 to 58,000 BTU per hour. Model WR2500X02 is listed by OMNI-Test Laboratories of Portland, OR and meets UL 1482 for the US and ULC S 627-00 for Canada.
  • Page 4: Installation

    Windsor High Efficiency Wood Insert Installation Clearance to Combustible Constructions 1. Remove all boxes of firebricks and any packaging Refer to Page 5 for further instructions about floor from inside the appliance. protection. 2. Clean out the masonry fireplace ensuring the ashes fAILURE to foLLoW tHESE MInIMUM CLEAR- are placed in a metal container.
  • Page 5: Floor Protection

    Windsor High Efficiency Wood Insert ST1031 Figure 3 Install Firebrick Tip - Install Front (*) Fire Bricks First floor Protection This appliance must be installed in a masonry fireplace ST1031 enclosure built in accordance install firebrick with local building codes. Do 10/08 not InStALL In A fACtoRy ST1023...
  • Page 6 Windsor High Efficiency Wood Insert 6” (152 mm) Min. Dia. Stainless Steel Flexible Figure 5 Liner Face Plate Assembly notES: A stain- less steel adapter is recommended for fastening the stainless steel flexible liner to the collar. Male or crimped end of the adapter must be installed inside the flue collar.
  • Page 7: Blower Installation

    Windsor High Efficiency Wood Insert 5. Do not use makeshift compromises during installa- Chimney Liner tion. The cross-sec- 6. Do not remove bricks or mortar from the fireplace. tional area must not Chimney Con- exceed 85 square EXCEPtIon (5) Page 7: nector into the inches (550 cm Masonry or steel, including the damper plate, may be...
  • Page 8: Operation

    Windsor High Efficiency Wood Insert operation Do not use a grate or elevate fire. Build wood fire directly on hearth. When the stove is used for the first Face Plate time the solvents in the paint will smoke off. Wood This heater is designed to burn natural wood only.
  • Page 9: Building A Fire

    Windsor High Efficiency Wood Insert It is normal to see flat spots on painted surfaces of the Inlet Air Control Settings stove. The flat spots on the paint surface indicate the Desired Inlet **Approx. hotter surfaces of the stove, and is caused by the heat Burn Setting Air Setting BtU output...
  • Page 10: Ash Disposal

    Windsor High Efficiency Wood Insert The following steps should be followed for door gasket WARnInG: things to remember in case of chim- replacement: ney fire: 1. Close draft control. 2. Call the fire de- 1. Ensure appliance is not in operation and has thor- partment.
  • Page 11 Windsor High Efficiency Wood Insert kindling, some additional kindling may be needed 5. Why can’t I get the fire lit? to sustain the fire. Do not add more paper after Damp or wet wood and poor draft are the main rea- the fire has started.
  • Page 12 Windsor High Efficiency Wood Insert This condition is commonly referred to as down d. Chimney Installation and Maintenance drafting. There are several factors that impact the Avoid using too many elbows or long horizontal amount of air available in the home. Increased runs.
  • Page 13 18  18  18  18  18  18  20  32  MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 5129 WR2500X02 Wood Insert WR2500x2 parts Item no. Description Qty. Part no.
  • Page 14 Windsor High Efficiency Wood Insert WR2500X02 Wood Insert (continued) Item No. Description Qty. Part No. Baffle Assembly S41467 Secondary Air Tube S32711 Cotter Pin S11421 Firebrick 4M\zn” (113 mm) x 9” (229 mm) x 1Z\v” (32 mm) S16040 Firebrick 4M\zn” (113 mm) x 7Z\v” 184 mm) x 1Z\v” (32 mm) S16043 Firebrick 4M\zn”...
  • Page 15: Limited Lifetime Warranty

    To clean glass, use a ceramic glass 7. MHSC neither assumes, nor authorizes any third party to as- cleaner or polish. Do not use ammonia-based cleaners. A suit- sume, on MHSC’s behalf, any other liabilities with respect to the able cleaner is available from your nearest Hearth Products deal- sale of this MHSC product.
  • Page 16 Windsor High Efficiency Wood Insert Approuv par l’EPA com- me pole insr Windsor  grande efficacit Modle WR2500X02 Guide du propritaire Pour installation rsidentielle 5129 note concernant la scurit WR2500X02 cover Lire le manuel en entier avant d’installer et d’utiliser votre pole insr.
  • Page 17 Windsor High Efficiency Wood Insert Mise En Garde 14.Une fois que le tirage requis est tabil, n’utilisez votre appareil qu’en tenant les portes fermes; ovrez Aprs avoir lu ces instructions, si vous avez des doutes les portes lentement lorsque vous remettez du bois quant  votre capacit de faire toute l’installation d’une dans le foyer.
  • Page 18 PoSSIBLE DE ConDItIonS HASARDEUSES. Caractristiques Modle WR2500X02 non-catalytique. Ce pole respecte les limits d’emission pour les poles  bois fixes par l’agence Amricaine de protection de l’environnement. Dans des conditions spcifiques, ce pole dgage entre 9 500  58 000 BTU  l’heure.
  • Page 19 Windsor High Efficiency Wood Insert Installation 1. Retirez de l’appareil toute bote de briques et autres l’arrire de l’appareil) et ci-dessous, pour la spara- paquets. tion des matriaux combustibles et la protection du plancher. Voir  la page 5 d’autres instructions au 2.
  • Page 20 Windsor High Efficiency Wood Insert ST1031 Figure 3 Installation de la brique rfractaire Avis - Installer les briques (*) du devant en premier Protecteur de plancher Cet appareil doit tre install ST1031 dans une enceinte de foyer en install firebrick maonnerie construite conform- 10/08 ST1023...
  • Page 21 Windsor High Efficiency Wood Insert 3. Faire glisser la plaque frontale contre le mur de ma locales du btiment pour les conditions requis dans onnerie. Attention : Pour viter de dtriorer la sur- votre region. face suprieure du pole, utiliser comme protection 2.
  • Page 22 Windsor High Efficiency Wood Insert glementaire locale (inspection des btiments). Lors chemines, fabriques en usine, de type rsidentiel de l’installation en conjonction avec une chemin et les appareils de chauffage des btiments, UL103; e de maonnerie, on doit installer dans la premire section de la doublure de chemine un conduit de 2.
  • Page 23 Windsor High Efficiency Wood Insert Chemisage de protection Pole ins tiquette Ouvert en mtal ST1029 Ferme ST1028 Figure 9 Installe une tiquette sur le foyer Poigne  ressort Assemblage le ventilateur 1. Retirez les vis du pole insr; passez le cordon sous le corps et passez-le par la dbouchure.
  • Page 24 Windsor High Efficiency Wood Insert Pendant le mrissement de la peinture, cette derni Utilisation du pole re deviendra collante. Une fois qu’elle est mrie, la peinture restera dure. Il est normal de voir des en- N’utilisez pas de grille dans le pole pour relever le feu. droits mats sur les surfaces peintes de votre pole.
  • Page 25 Windsor High Efficiency Wood Insert d’air pour que le bois mieux allum produise plus de Remplacement d’un joint flammes. bien que vous ayez la rgle pratique de ( Aprs un usage intensif, le matriau des joints de la peine ouvert), ( demi ouvert) et (totalement ouvert), porte et de la vitre peut devoir tre remplac s’il a perdu vous pouvez obtenir plus de resignements sur la son lasticit.
  • Page 26 Windsor High Efficiency Wood Insert Comment prvenir l’accumulation de crosote limination de la cendre 1. Plusieurs fois par jour durant la saison de chauffage, L’appareil est muni d’une tablette sure le devant pour ouvrez le volet d’admission d’air pendant plusieurs faciliter l’enlvement de la cendre.
  • Page 27 Windsor High Efficiency Wood Insert 2. Quel est le meilleur type de bois qu’on peut IMPoRtAnt utiliser dans le pole? Conseils qui valent la peine d’tre rpts Vous devriez utiliser du bois dur sec. vitez d’utiliser du bois vert. En plus de donner un rendement d’ 1.
  • Page 28 Windsor High Efficiency Wood Insert 8. Qu’entend-on par tirage? b. Conditions environnementales Le tirage peut tre exprim comme tant la capacit Les grands arbres, les dpressions, comme une de la chemine  vacuer les sous-produits de toule valle, les grands difices ou structures adjacents combustion normale.
  • Page 29 18  20  32  MHSC se rserve le droit de faire des changements en ce qui concerne la conception, les matriaux, les spcifications et les prix et de discontinuer des couleurs et des produits  tout moment sans pravis. 5129 Pole insr WR2500X02 WR2500x2 parts...
  • Page 30 Windsor High Efficiency Wood Insert Pole insr WR2500X02 (suite) Description Qte. no. pice Baffle AssemblyDflecteur S41467 Tube d’air secondaire S32711 Goupille fendue S11421 Brique rfractaire 113 mm (4M\zn po) x 229 mm (9 po) x 32 mm (1Z\v po) S16040...
  • Page 31 Windsor High Efficiency Wood Insert Garantie de dure limite MHSC garantit que les poles  bois en fonte ou les foyers  bois en n’assumera aucune responsibilit pour de tois frais. De plus, MHSC pierres de marque Windsor sont exemple de tout dfaut de fabrication et ne sera tenu responsable d’aucun dommage conscutif ou indirect,...
  • Page 32 MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com...

Table of Contents