11.4
Diagnostic Messages,
Diagnostic Messages,
Table 32
continued
SMV Status
SCT Status Message SFC Display Message TDC Status Message
9-7
Reynolds Number is Out
of Range
8-7
Sensor Mismatch PV3
1/99
Continued
Non-Critical Status Diagnostic Message Table, Continued
-
STATUS 9-7
SAVE/RESTORE
SNSR MISMTCH PV3
TYPE MISMATCH
SMV 3000 Transmitter User's Manual
Possible Cause
The high or low Reynolds number
limit was exceeded.
Number of wires selected does not
match number of sensor wires
physically connected to the
transmitter.
What to Do
Verify high or low Reynolds
number limit.
Calculate Reynolds number
for flow conditions causing the
message.
Check sensor wiring and type.