Honeywell ADEMCO LYNXR Series Installation And Setup Manual page 10

Honey security systems installation and setup guide
Hide thumbs Also See for ADEMCO LYNXR Series:
Table of Contents

Advertisement

AC Power and Backup Battery
AC Power and Rechargeable Backup Battery
The LYNXR Series is equipped with an integral, replaceable, rechargeable battery pack composed of six (6)
rechargeable 1.2-volt nickel-metal hydride batteries. Select the appropriate battery pack, based on the
installation's requirement, and install the battery pack.
Model/Part Number
LYNXRCHKIT-SC
LYNXRCHKIT-HC
Replacing the Rechargeable Battery
1. When battery replacement is required, unplug
the transformer from the wall outlet, and open
the control panel cover.
2. Remove the battery retainer and disconnect the
battery pack connector from the receptacle on
the terminal block PC board.
3. Remove the battery pack from the back plate.
4. If required, replace the tape that secures the
battery pack.
5. Install
a
replacement
LYNXRCHKIT-SC or LYNXRCHKIT-HC) into the
back plate.
6. Install the battery retainer.
7. Connect
the
battery
receptacle on the terminal block PC board.
8. After the wiring connection has been made,
snap the front assembly to the back plate.
9. Plug the transformer into a 24-hour, 110VAC
unswitched outlet.
10. Rechargeable batteries may take up to 48-
hours to fully charge. The "LOW BAT" message
should clear within four hours or by entering
Test Mode.
Ensure the control panel assembly is snapped closed prior to applying AC power.
Battery StandbyTime
4-hours (minimum)
24-hours (minimum)
RETAINER
BATTERY
battery
pack
(P/N
connector
to
the
Low Battery Notification
Approximately 1-hour before battery depletion
At least 1-hour before battery depletion
LYNXRCHKIT-HC
PACK
BATTERY
CONNECTOR
BATTERY
RECEPTACLE
–10–
OR
LYNXRCHKIT-SC
TAPE