OPERATION
HS1132:
Pull the choke knob to the CLOSED position and move the throttle lever to
the FAST position.
CHOKE KNOB
e
CLOSED
THROTTLE LEVER
5. Start the engine.
Electric-start Models (TAS, WAS type):
a. Connect your power cord to the switch box and the male end of the
power cord to a properly grounded
120
volt ac outlet.
I
ACAUTION
I
I U S E ONLY WITH GROUNOEO OUTLET AN0
1 1 2 0 VOLT A.C. ONLY
1 0 0 NOT CRANK OVER 1 MINUTE WllHOLlT
COOLING 15 MINUTES.
1 0 0 NOT USE IN RAIN.
3-WIRE CORD.
I
POWER CORD
To minimize the possibility of potentially dangerous electrical shocks, always
use a 3-conductor power cord with a power rating of no less than 15 amps.
Also, be sure that the outlet you are using is properly grounded.
Do not connect and disconnect the power cord with wet hands.
Be sure to hold the plug when disconnecting the power cord from the electrical
outlet or switch box. Do not disconnect by pulling on the power cord.