Honda EX3300S Owner's Manual

Honda EX3300S Owner's Manual

Honda portable generator owner's manual
Hide thumbs Also See for EX3300S:

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Honda EX3300S

  • Page 2 generator is a potential source of electrical shock misused. Do not expose the generator to moisture, rain or snow. Do not let the generator get wet, and do not operate it with wet hands.
  • Page 3 Honda dealer. are designed to give safe and dependable to instructions. operating the generator. or equipment damage. of EX3300S is based on the It is illegal in words: or death will result if in- injury or loss of damage if...
  • Page 4: Table Of Contents

    CONTENTS CONTENTS 1. GENERATOR SAFETY ... 2. COMPONENT IDENTIFICATION 3. PRE-OPERATION CHECK ... 4. STARTINGTHE ENGINE ... 5. GENERATOR USE ... High altitude operation 6. STOPPING THE ENGINE ... 7. MAINTENANCE 8. TRANSPORTING/STORAGE 9. TROUBLESHOOTING 10. WIRING DIAGRAM 11. SPECIFICATIONS 12.
  • Page 5: Generator Safety

    Place the generator on a firm, level surface; the generator is tilted or overturned, generator is overturned may enter the generator. To prevent fire hazards generator at least 1 meter (3 feet) away from buildings ment during operation. generator. Know how to stop the generator of all the controls.
  • Page 6 [, EX4500S CAUTION BE SURE TO FILL CRANKCASE WITH RECOMMENDED BEFORE USING. FOR DETAILED EXPLANATION. SEE THE OWNER’S MANUAL EX3300S CAUTION BE SURE TO FILL CRANKCASE WITH RECOMMENDED BEFORE USING. FOR DETAILED EXPLANATION, SEE THE OWNER’S MANUAL. HONDA MOTOR CO., LTD.
  • Page 7 AnENTl(-jN NE PAS UTILISER DANS UN ENDROIT FERME A CAUSE DU RISQUE D’EMPOISONNENT ATENCl()N NO LO USE EN LUGARES CERRADOS PORQUE EL MONOXIDE DE CARBON0 ES VENENOSO. DU GAZ. ICHECK FOR SPILLED FUEL OR FUEL LEAKS. STOP ENGINE BEFORE REFUELING. REPANOUE SUR L’APPAREIL.
  • Page 8: Component Identification

    2. COMPONENT IDENTIFICATION OIL ALERT LAM!’ ENGINE SWITCH VOLTAGE SELECTOR AC RECEPTACLES FRONT MAINTENANCE COVER...
  • Page 9 FUEL TANK CAP UPPER MAINTENANCE COVER SPARK PLUG ’ AIR CLEANER REAR MAINTENANCE COVER...
  • Page 10: Pre-Operation Check

    3. PRE-OPERATION CHECK CAUTION: Check the generator 1. ENGINE OIL CAUTION: Engine oil is a major factor service life. Non-detergent Use Honda 4-stroke oil, or an equivalent motor oil certified to meet or exceed U.S. automobile quirements for Service Classification SG, SF/CC, CD will show this designation SAE lOW/30 is recommended...
  • Page 11 2. FtiEL Check the fuel gauge and ,refill the tank if the fuel level is low. Your engine is designed ( R ‘2 M ) of 86 number tane number of 91 or higher. Gasoline pumps at service station normally display the pump octane number.
  • Page 12 Gasoline is extremely Refuel in a well-ventilated allow flames or sparks in the area where the engine is refueled gasoline is stored. Do not overfill the fuel tank (there should be no fuel in the filler neck). After refueling, make sure the tank cap is closed prdperly Be careful not to spill fuel when refueling.
  • Page 13 3. Check the battery. The electrolyte level must be maintained between the UPPER and LOWER level marks. If the electrolyte water. The battery gives off explosive tes away. Provide adequate in an enclosed space. The battery contains eyes may cause severe shield.
  • Page 14: Startingthe Engine

    4. STARTING THE ENGINE CAUTION: When starting after long-term storage, to the “ON\’ position, engine. 1. Turn off the AC circuit breaker. 2. Make sure the auto-throttle for warm up. the generator after adding fuel for the first time, or after running out of fuel, turn the engine switch then wait for 10 to 20 seconds AC CIRCUIT BREAKER...
  • Page 15 3. Turn the engine switch to the START position and hold it there until the engine starts. NOTE: Do not use the electric starter for more than 5 seconds at a time. If the engine fails to start, release the switch and wait 10 seconds before operating the starter again.
  • Page 16: Generator Use

    CAUTION Limit operation requiring kVA for EX3300S) For continuous operation, EX4500S. 3.0 kVA for EX3300S. In either case, the total considered. Most appliance motors Do not exceed the current shock from faulty...
  • Page 17 Auto-throttle System With the switch in the AUTO position, engine speed is automatically ed to an idle when all loads are turned off or disconnected. pliances are turned on or reconnected, At OFF, the auto-throttle NOTE: AUTO is recommended applied. The auto-throttle system will not respond to electrical loads of less than 1 ampere.
  • Page 18 AC operation , 1. Start the engine. 2. Turn the voltage selector switch to either position as required. NOTE: With the voltage selector switch in the “12OV/24OV” can use the 120V and 240V receptacles simultaneously. ing the 240V receptacle, but you require more power from the 12OV twist- lock receptacle, then turn the switch to the “120V”...
  • Page 19 DC application The DC terminals may be used for charging 12 bolt automotive-type teries only. 1. Connect both charging cables to the battery terminals and connect the positive (+I cable to the generator’s 2. Start the generator. 3. Carefully connect the negative negative (-1 DC terminal.
  • Page 20: High Altitude Operation

    CAUTION Be careful to connect generator terminals charging cables are connected battery or generator Do not attempt to start an automobile connected to the battery; NOTE: The DC terminals An overloaded DC circuit ‘will trip the DC circuit protector dicator in the push button.pops before pushing the circuit protector to resume operation.
  • Page 21: Stopping The Engine

    6: STOPPING THE ENGINE NOTE: To stop the engine in an emergency, turn the engine switch to the OFF position. In normal use: 1. Move the AC circuit breaker to the OFF position. Disconnect DC battery charging cables. AC CIRCUIT BREAKER 2.
  • Page 22: Maintenance

    7. MAINTENANCE Periodic maintenance good operating condition. the table on the following Shut off the engine engine must be run, make sure the area is well ventilated. tains poisonous carbon CAUTION: only maintenance or repair. quality may damage the generator. Maintenance Schedule \ REGULAR SERVICE PERIOD Performed...
  • Page 23 Tool kit The tools supplikd with the generator will help you to perform the owner- maintenance procedures listed on page 20. Always keep this tool kit with the generator TOOL KIT prqg 10 x 12 mm WRENCH PLUG WRENCH PLUG WRENCH HANDLE IL=! FLAT SCREWDRIVER REAR MAINTENANCE...
  • Page 24 Changing Drain the oil while the engine is still warm to assure rapid and complete draining. 1. Open the front maintenance 2. Remove the drain bolt and filler cap, and drain the oil. Retighten the bolt securely. 3. Refill with the recommended 4.
  • Page 25 Air cleaner service A dirty air cleaner will restrict air flow to the carburetor. buretor malfunction, service the air cleaner regularly (page 201. Service more frequently when operating the generator in extremely Never use gasoline air cleaner element. A fire. or explosion CAUTION: Never run the generator wear will result.
  • Page 26 Spark plug service Recommended spark plug: To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. 1. Open the rear maintenance 2; Remove the spark plug cap. 3. Clean any dirt from around the spark plug base. 4.
  • Page 27 7. Check that the spark plug washer is in good condition, spark plug in by hand to prevent cross-threading. 8. After the spark plug is seated, tighten with a spark plug wrench to com- press the washer. NOTE: If installing a new spark plug, tighten seats to compress the washer.
  • Page 28 Fuel sediment cup cleaning The sediment cup prevents dirt or water which may be in the fuel tank from entering the carburetor. sediment cup should be cleaned. 1. Open the left side maintenance 2. Turn the engine switch to the OFF position. by turning it counterclockwise.
  • Page 29 Spark arrester maintenance If the generator Allow it to cool before CAUTION: The spark arrester tain its efficiency. 1. Remove the nine 6 mm bolts, the handle and right side cover. 2. Remove the two 5 mm pan screws, and remove the spark arrester. has been running, proceeding.
  • Page 30 3. Use a brush to remove carbon deposits from the spark arrester screen. ’ NOTE: Inspect the spark arrester screen for holes or tears. Replace if necessary. 4. Reinstall the spark arrester, right side cover and handle.
  • Page 31 Fuse replacement The fuse holder is located on the battery container. 1. Turn the engine switch to the OFF position. 2. Open the left side maintenance replace the fuse. The specified fuses are 1 A, 5A, 1 OA. CAUTION: If frequent fuse failure ’...
  • Page 32: Transporting/Storage

    8. TRANSPORTING/STORAGE When transporting and keep the generator fuel may ignite. Before storing the unit for an extended period: 1. Be sure the storage area is’ free of excessive humidity 2. Drain the fuel- a. Open the rear maintenance b. Turn the engine switch and then loosen the carburetor drain screw.
  • Page 33: Troubleshooting

    When the engine will not start: Is there fuel in the tank? Is there enough in the engine? (The oil alert lamp goes on when cranking Is there a spark from the spark plug? To check: Be sure there is no spilled fuel around 2) Remove...
  • Page 34 Nb electricity at the AC receptacles: breaker Check the electrical appliance or equip- ment for any defects NO DEFECTS DEFECTS Turn the AC circuit breaker Take the generator ) to an authorized Honda dealer. Take the electrical ,appliance equipment to an electrical shop for repair.
  • Page 35: Wiring Diagram

    110. BRlNG DIAGRAIVI EX3300S...
  • Page 37: Specifications

    Rated Frequency AC output Rated Ampere Rated Output Maximum DC output 11. SPEClFlCATldNS EX3300S 91Ox530x695,mm (35.8 109 kg (240.3 GX240 242 cc (14.8 :73 x 58 mm (1’.9 x 2.3 id1 182 x 64 mm (3.2 x 2.5 in)1 8.2 : 1 1.1 P (1.16...
  • Page 38: Installation Of Optional Parts

    12. INSTALLATION Remote Control Kit (Installation) 1. Remove the panel from the front cover. 2. Disconnect the jumper coupler from the 9-P coupler. 3. Connect the 9-P coupler of the remote control panel to the 9-P coupler disconnected in step ‘2. 4.
  • Page 39 STARTING WITH REMOTE 1. Make sure the engine switch is OFF. 2. Turn the auto throttle 3. Remove the ignition switch key from the generator. ’ 4. Turn the remote control switch to ON. 5. Flip the remote control engine switch,.knob 6.
  • Page 40: Warranty Service

    13. WARRANTY SERVICE Owner Satisfaction Your satisfaction and goodwill Honda warranty details are explained in the Distributor’s Normally, any problems concerning dealer’s service department. been handled to your satisfaction,’ action: Discuss your problem with a member of dealership management. complaints can be quickly already been reviewed with the Service Manager, contact the owner of the dealership or the General Manager.
  • Page 41 MEMO...
  • Page 42 MEMO...

This manual is also suitable for:

Ex4500s

Table of Contents