Honda EM7000is Owner's Manual

Honda EM7000is Owner's Manual

Honda generator owner's manual
Table of Contents

Advertisement

Quick Links

79

Advertisement

Table of Contents
loading

Summary of Contents for Honda EM7000is

  • Page 2 The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Keep this owner’s manual handy, so you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should remain with the generator if resold.
  • Page 3 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased with your purchase of one of the finest generators on the market. We want to help you get the best results from your new generator and to operate it safely.
  • Page 4 A FEW WORDS ABOUT SAFETY Your safety and the safety of others are very important. And using this generator safely is an important responsibility. To help you make informed decisions about safety, we have provided operating procedures and other information on labels and in this manual.
  • Page 5: Table Of Contents

    CONTENTS GENERATOR SAFETY IMPORTANT SAFETY INFORMATION Operator Responsibility Carbon Monoxide Hazards Electric Shock Hazards Fire and Burn Hazards Refuel With Care SAFETY LABEL LOCATIONS CONTROLS & FEATURES COMPONENT & CONTROL LOCATIONS CONTROLS Fuel Valve Lever Engine Switch Recoil Starter EcoThrottle Switch Voltage Selector Switch AC Circuit Protectors Folding Handle...
  • Page 6 CONTENTS OPERATION SAFE OPERATING PRECAUTIONS STARTING THE ENGINE Starting the engine with remote control (optional part) STOPPING THE ENGINE Stopping the engine with remote control (optional part) AC OPERATION AC Applications AC Receptacle Selection ECOTHROTTLE SYSTEM STAND BY POWER Connections to a Building’s Electrical System System Ground Special Requirements SERVICING YOUR GENERATOR...
  • Page 7 TRANSPORTING TAKING CARE OF UNEXPECTED PROBLEMS ENGINE PROBLEMS GENERATOR PROBLEMS TECHNICAL & CONSUMER INFORMATION TECHNICAL INFORMATION Serial Number Location Carburetor Modification for High Altitude Operation Oxygenated Fuels Emission Control System Information Air Index Specifications Wiring Diagram CONSUMER INFORMATION Honda Publications Customer Service Information ASSEMBLY SAFETY...
  • Page 8: Generator Safety

    GENERATOR SAFETY IMPORTANT SAFETY INFORMATION Honda generators are designed for use with electrical equipment that has suitable power requirements. Other uses can result in injury to the operator or damage to the generator and other property. Most accidents can be prevented if you follow all instructions in this manual and on the generator.
  • Page 9: Electric Shock Hazards

    Electric Shock Hazards The generator produces enough electric power to cause a serious shock or electrocution if misused. Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution.
  • Page 10: Refuel With Care

    GENERATOR SAFETY Refuel With Care Gasoline is extremely flammable, and gasoline vapor can explode. Allow the engine to cool if the generator has been in operation. Refuel only outdoors in a well-ventilated area with the engine OFF. Do not overfill the fuel tank. Never smoke near gasoline, and keep other flames and sparks away.
  • Page 11: Safety Label Locations

    GENERATOR SAFETY SAFETY LABEL LOCATIONS These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your Honda servicing dealer for a replacement.
  • Page 12: Controls & Features

    CONTROLS & FEATURES COMPONENT & CONTROL LOCATIONS Use the two illustrations on these pages to locate and identify the most frequently used controls. OVERLOAD INDICATOR OUTPUT INDICATOR i-MONITOR ENGINE SWITCH VOLTAGE SELECTOR SWITCH OIL ALERT INDICATOR i-MONITOR BUTTON FUEL VALVE CIRCUIT PROTECTORS RECEPTACLES ECOTHROTTLE SWITCH...
  • Page 13 FUEL GAUGE SPARK PLUG INSPECTION COVER WHEEL AIR CLEANER STARTER GRIP GROUND TERMINAL OIL DRAIN PLUG CONTROL & FEATURES FUEL TANK CAP FUSE(Inside maintenance cover) STAND OIL FILLER CAP/DIPSTICK HANDLE BATTERY TRAY (Inside maintenance cover) MUFFLER TIP...
  • Page 14: Controls

    CONTROL & FEATURES CONTROLS Fuel Valve Lever The fuel valve lever is located on the control panel. The fuel valve must be in the ON position for the engine to run. After stopping the engine, turn the fuel valve to the OFF position. Engine Switch The engine switch controls the ignition system, and it operates...
  • Page 15: Recoil Starter

    Recoil Starter Pulling the starter grip operates the recoil starter to crank the engine for starting. Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter. Do not let the starter rope rub against the generator body or the rope will wear out prematurely.
  • Page 16: Voltage Selector Switch

    CONTROL & FEATURES Voltage Selector Switch The voltage selector switch switches generator output to produce ‘‘120 V ONLY’’ or ‘‘120/240V’’. If a 240V appliance is connected to the 4- prong receptacle, the switch must be in the ‘‘120/240V’’ position. If only a 120V appliance is being connected to any of the 120V 3-prong receptacles, select the ‘‘120V ONLY’’...
  • Page 17: Folding Handle

    Folding Handle The foldable handle is intended for ease of transportation and should be folded when the generator is stationary. Do not rest objects on extended handle. To Extend Handle Lift handle upward. Lock levers will lock and secure handle into place. To Fold Handle Press both handle lock levers downward.
  • Page 18: Features

    CONTROL & FEATURES FEATURES Ground Terminal The ground terminal is connected to the frame of the generator, the metal non-current-carrying parts of the generator, and the ground terminals of each receptacle. Before using the ground terminal, consult a qualified electrician, electrical inspector or local agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator.
  • Page 19: Output Indicator

    Output Indicator The output indicator (green) is illuminated when the generator is operating normally. It indicates that the generator is producing electrical power at the receptacles. OUTPUT INDICATOR (GREEN) Overload Indicator If the generator is overloaded, or if there is a short circuit in a connected appliance, or if the inverter is overheated, the overload indicator (red) will go ON.
  • Page 20: Oil Alert Indicator

    CONTROL & FEATURES Oil Alert Indicator The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the Oil Alert indicator comes on and the Oil Alert system automatically will stop the engine (the engine switch will remain in the ON position).
  • Page 21: I-Monitor Tm

    i-Monitor The i-Monitor is a user interface that allows the operator to view (when the generator is running) total operating time in hours, generator output, engine RPM, battery voltage and error messages. The different display modes are selected by pressing the i-Monitor button.
  • Page 22 CONTROL & FEATURES i-Monitor Display Mode 2 This mode displays an approximate generator output on the display screen. The output is expressed in VA (volt-amperes). The output value is not an exact measurement and should be regarded as a reference only. Power output will not display until a load is connected to the generator.
  • Page 23 i-Monitor Low Battery Message If the engine switch is turned to the START position and ‘‘batt’’ is shown on the i-Monitor display, the battery voltage is too low to operate the engine’s electric starter. Use the recoil starter to start the generator.
  • Page 24: Fuel Gauge

    CONTROL & FEATURES Fuel Gauge The fuel gauge is a mechanical device that measures the fuel level in the tank. The red indicator in the window will reference the level in relation to full or empty. To provide increased operating time, start with a full tank before beginning operation.
  • Page 25: Before Operation

    BEFORE OPERATION ARE YOU READY TO GET STARTED? Your safety is your responsibility. A little time spent in preparation will significantly reduce your risk of injury. Knowledge Read and understand this manual. Know what the controls do and how to operate them. Familiarize yourself with the generator and its operation before you begin using it.
  • Page 26: Check The Engine

    BEFORE OPERATION Check the Engine Check the oil level (see page ). A low oil level will cause the Oil Alert system to shut down the engine. Check the air filter (see page ). A dirty air filter will restrict air flow to the carburetor, reducing engine and generator performance.
  • Page 27: Operation

    OPERATION SAFE OPERATING PRECAUTIONS Before operating the generator for the first time, please review the GENERATOR SAFETY section and the chapter titled BEFORE OPERATION . For your safety, avoid starting or operating the generator in an enclosed area such as a garage. Your generator’s exhaust contains poisonous carbon monoxide gas which can collect rapidly in an enclosed area and cause illness or death.
  • Page 28: Starting The Engine

    OPERATION STARTING THE ENGINE Refer to Safe Operating Precautions on page Make sure that all appliances are disconnected from the AC receptacles. The generator may be hard to start if a load is connected. Set the Voltage Selector Switch to match the voltage requirements for the application.
  • Page 29 Start the engine Using the electric starter: Turn the engine switch to the START position, and hold it there until the engine starts. When the engine starts, release the key, allowing the switch to return to the ON position. If the engine fails to start within 5 seconds, release the key, and wait at least 10 seconds before operating the...
  • Page 30 OPERATION Using the recoil starter: Turn the engine switch to the ON position. Pull the starter grip lightly until you feel resistance, then pull briskly. Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter.
  • Page 31: Starting The Engine With Remote Control (Optional Part)

    Starting the engine with remote control (optional part) Determine the voltage requirements and adjust the voltage selector switch, as needed. Turn the fuel valve to the ON position. Turn the engine switch to the REMOTE (far left) position. REMOTE ENGINE SWITCH Press and hold the start button until the engine pilot lamp illuminates.
  • Page 32: Stopping The Engine

    OPERATION STOPPING THE ENGINE To stop the engine in an emergency, simply turn the engine switch to the OFF position. Under normal conditions, use the following procedure. Unplug all appliances from all generator AC receptacles. Turn the engine switch to the OFF position.
  • Page 33: Stopping The Engine With Remote Control (Optional Part)

    Stopping the engine with remote control (optional part) Press the stop button. PILOT LAMP Turn the engine switch to the OFF position. Turn the fuel valve lever to the OFF position. REMOTE STOP BUTTON ENGINE SWITCH OPERATION FUEL VALVE...
  • Page 34: Ac Operation

    OPERATION AC OPERATION If an appliance begins to operate abnormally, becomes sluggish or stops suddenly, turn it off immediately. Disconnect the appliance, and determine whether the problem is in the appliance, or if the rated load capacity of the generator has been exceeded. Substantial overloading that continuously lights the overload indicator (red) may damage the generator.
  • Page 35 Plug in the appliance. Most motorized appliances require more than their rated wattage for startup. If the generator is overloaded, or if there is a short circuit in a connected appliance, or if the inverter is overheated, the overload indicator (red) will come ON. The overload indicator (red) will stay ON, and after about five seconds, current to the connected appliance(s) will shut off, and the output indicator (green) will go OFF.
  • Page 36: Ac Applications

    Limit operation requiring maximum power to 30 minutes. Maximum power is: EM5000is: 5,000 VA EM7000is: 6,500 VA For continuous operation (longer than 30 minutes), do not exceed the rated power. Rated power is:...
  • Page 37: Ac Receptacle Selection

    120/ 240 V locking plug receptacle is used for 120 V. The total rated ampere draw is: EM5000is: 37.5 A EM7000is: 45.8 A EM5000is Main power circuit Main Circuit I...
  • Page 38 OPERATION Example: EM5000is Receptacle 1 has a 15A load connected to it. Receptacle 3 has a 10A load connected to it. Both receptacles are powered by main power circuit I. The equation tells us that the total power draw on circuit I is 25A.
  • Page 39: Ecothrottle System

    ECOTHROTTLE SYSTEM With the switch in the ON position, engine speed is automatically lowered when loads are reduced, turned OFF or disconnected. When appliances are turned ON or reconnected, the engine returns to the proper speed to power the electrical load. In the OFF position, the EcoThrottle system does not operate.
  • Page 40: Stand By Power

    OPERATION STAND BY POWER Connections to a Building’s Electrical System Your generator can supply power to a building’s electrical system. If the generator will be used as an alternative to utility company power, an isolation switch must be installed to disconnect the utility lines from the building when the generator is connected.
  • Page 41: Special Requirements

    Special Requirements There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction. In some areas, generators are required to be registered with local utility companies.
  • Page 42: Servicing Your Generator

    SERVICING YOUR GENERATOR THE IMPORTANCE OF MAINTENANCE Good maintenance is essential for safe, economical, and trouble-free operation. It will also help reduce air pollution. To help you properly care for your generator, the following pages include a maintenance schedule, routine inspection procedures, and simple maintenance procedures using basic hand tools.
  • Page 43: Maintenance Safety

    MAINTENANCE SAFETY Some of the most important safety precautions follow. However, we cannot warn you of every conceivable hazard that can arise in performing maintenance. Only you can decide whether or not you should perform a given task. Failure to properly follow maintenance instructions and precautions can cause you to be seriously hurt or killed.
  • Page 44: Maintenance Schedule

    SERVICING YOUR GENERATOR MAINTENANCE SCHEDULE REGULAR SERVICE PERIOD (3) ITEM Perform at every indicated month or operating hour interval, whichever comes first. Engine oil Air filter Sediment cup Spark plug Spark arrester Valve clearance Combustion chamber Fuel tank and filter Fuel tube Service more frequently when used in dusty areas.
  • Page 45: Refueling

    REFUELING With the engine stopped, check the fuel level gauge. Refill the fuel tank if the fuel level is low. Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel. Stop the engine and keep heat, sparks, and flame away.
  • Page 46: Fuel Recommendations

    SERVICING YOUR GENERATOR FUEL RECOMMENDATIONS Use unleaded gasoline with a pump octane rating of 86 or higher. This engine is certified to operate on unleaded gasoline. Unleaded gasoline produces fewer engine and spark plug deposits and extends exhaust system life. Never use stale or contaminated gasoline or an oil/gasoline mixture.
  • Page 47: Engine Oil Level Check

    ENGINE OIL LEVEL CHECK Check the engine oil level with the generator on a level surface and the engine stopped. Remove the oil filler cap/dipstick and wipe it clean. Insert and remove the dipstick without screwing it into the filler neck. Check the oil level shown on the dipstick.
  • Page 48: Engine Oil Change

    SERVICING YOUR GENERATOR ENGINE OIL CHANGE Drain the oil while the engine is warm to assure rapid and complete draining. Place a suitable container below the engine to catch the used oil, then remove the oil filler cap/dipstick, drain plug and sealing washer. Allow the used oil to drain completely, then reinstall the drain plug and sealing washer.
  • Page 49: Engine Oil Recommendations

    SERVICING YOUR GENERATOR ENGINE OIL RECOMMENDATIONS Oil is a major factor affecting performance and service life. Use 4-stroke automotive detergent oil. SAE 10W 30 is recommended for general use. Other viscosities − shown in the chart may be used when the average temperature in your area is within the recommended range.
  • Page 50: Air Cleaner Service

    SERVICING YOUR GENERATOR AIR CLEANER SERVICE Loosen the cover screws and remove the air cleaner cover. FOAM AIR FILTER COVER SCREW Remove the foam air filter from the air cleaner cover. Check the foam air filter to be sure it is clean and in good condition. If the foam air filter is dirty, clean it as described on page Replace the foam air filter if it is damaged.
  • Page 51: Foam Air Filter Cleaning

    FOAM AIR FILTER CLEANING A dirty foam air filter will restrict air flow to the carburetor, reducing engine performance. If you operate the generator in very dusty areas, clean the foam air filter more frequently than specified in the Maintenance Schedule. Clean the foam air filter in warm soapy water, rinse, and allow to dry thoroughly, or clean in...
  • Page 52: Sediment Cup Cleaning

    SERVICING YOUR GENERATOR SEDIMENT CUP CLEANING Turn the fuel valve lever to the OFF position and remove the key. Remove the sediment cup by turning it counterclockwise. Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel. Stop the engine and keep heat, sparks, and flame away.
  • Page 53: Spark Plug Service

    SPARK PLUG SERVICE Recommended spark plugs: Incorrect spark plugs can cause engine damage. Loosen the cover screw and remove the spark plug inspection cover. SPARK PLUG INSPECTION COVER COVER SCREW Disconnect the spark plug cap, and remove any dirt from around the spark plug area.
  • Page 54 SERVICING YOUR GENERATOR Inspect the spark plug. Replace it if the electrodes are worn or if the insulator is cracked, chipped or fouled. Measure the spark plug electrode gap with a wire-type feeler gauge. Correct the gap, if necessary, by carefully bending the side electrode.
  • Page 55: Spark Arrester Service

    SPARK ARRESTER SERVICE The spark arrester must be serviced every 100 hours to keep it functioning as designed. If the engine has been running, the muffler will be very hot. Allow the muffler to cool before servicing the spark arrester. Remove the two 8 mm flange bolts, and remove the rear bar.
  • Page 56 SERVICING YOUR GENERATOR Remove the three 6 mm flange bolts, and remove the exhaust tail pipe and the spark arrester. EXHAUST TAIL PIPE 6 mm FLANGE BOLT Use a brush to remove carbon deposits from the spark arrester screen. Be careful to avoid damaging the screen. The spark arrester must be free of breaks and holes.
  • Page 57: Battery Service

    BATTERY SERVICE Your generator’s engine charging system charges the battery while the engine is running. However, if the generator is only used periodically, the battery must be charged monthly to maintain the battery service life. The battery contains sulfuric acid (electrolyte) which is highly corrosive and poisonous.
  • Page 58 SERVICING YOUR GENERATOR Battery Removal WARNING: Battery posts, terminals and related accessories contain lead and lead compounds. Lift handle upward. Lock levers will lock and secure handle into place. Loosen the cover screw and remove the maintenance cover. COVER SCREW MAINTENANCE COVER Remove the negative ( ) cable from the battery negative ( ) terminal, then remove the positive ( ) cable from the battery...
  • Page 59 Battery Charging The battery gives off explosive hydrogen gas during normal operation. A spark or flame can cause the battery to explode with enough force to kill or seriously hurt you. Wear protective clothing and a face shield, or have a skilled mechanic do the battery maintenance.
  • Page 60: Fuse

    SERVICING YOUR GENERATOR FUSE If the fuse is blown, the starter motor won’t operate. In the event of fuse failure, locate the cause of failure and repair before you continue operation. If the fuse continues to fail, discontinue generator use and consult an authorized Honda generator dealer. Turn the engine switch OFF and remove the key before checking or replacing the fuse.
  • Page 61: Storage

    STORAGE STORAGE PREPARATION Proper storage preparation is essential for keeping your generator trouble-free and looking good. The following steps will help to keep rust and corrosion from impairing your generator’s function and appearance, and will make the engine easier to start when you use the generator again.
  • Page 62 STORAGE Adding a Gasoline Stabilizer to Extend Fuel Storage Life When adding a gasoline stabilizer, fill the fuel tank with fresh gasoline. If only partially filled, air in the tank will promote fuel deterioration during storage. If you keep a container of gasoline for refueling, be sure that it contains only fresh gasoline.
  • Page 63 Draining the Fuel Tank and Carburetor Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel. Stop the engine and keep heat, sparks, and flame away. Handle fuel only outdoors. Wipe up spills immediately. Place a suitable gasoline container below the carburetor drain hose.
  • Page 64: Engine Oil

    STORAGE Engine Oil Change the engine oil (see page Remove the spark plug (see page Pour a tablespoon (5 Pull the starter rope several times to distribute the oil in the cylinder. Reinstall the spark plug. Slowly pull the starter grip until resistance is felt. At this point, the piston is coming up on its compression stroke and both the intake and exhaust valves are closed.
  • Page 65: Storage Precautions

    STORAGE STORAGE PRECAUTIONS If your generator will be stored with gasoline in the fuel tank and carburetor, it is important to reduce the hazard of gasoline vapor ignition. Select a well-ventilated storage area away from any appliance that operates with a flame, such as a furnace, water heater, or clothes dryer. Also avoid any area with a spark-producing electric motor, or where power tools are operated.
  • Page 66: Transporting

    TRANSPORTING If the generator has been running, allow the engine to cool for at least 15 minutes before loading the generator on the transport vehicle. A hot engine and exhaust system can burn you and can ignite some materials. Keep the generator level when transporting to reduce the possibility of fuel leakage.
  • Page 67: Taking Care Of Unexpected Problems

    TAKING CARE OF UNEXPECTED PROBLEMS ENGINE PROBLEMS Engine Will Not Start Check control positions. Check fuel. Check engine oil level. Remove and inspect spark plug. Take generator to an authorized Honda servicing dealer, or refer to shop manual. Possible Cause Fuel valve lever OFF.
  • Page 68 TAKING CARE OF UNEXPECTED PROBLEMS Engine Lacks Power Check air filter. Check fuel. Take generator to an authorized Honda servicing dealer, or refer to shop manual. Possible cause Air filter restricted. Bad fuel; generator stored without treating or draining gasoline, or refueled with bad gasoline.
  • Page 69: Generator Problems

    TAKING CARE OF UNEXPECTED PROBLEMS GENERATOR PROBLEMS No Power at the AC Receptacles Check output and overload indicator. Check circuit protectors. Check the power tool or appliance at a known, good AC power source. Take generator to an authorized Honda servicing dealer, or refer to shop manual.
  • Page 70: Technical & Consumer Information

    TECHNICAL & CONSUMER INFORMATION TECHNICAL INFORMATION Serial Number Location FRAME SERIAL NUMBER Record the frame serial number in the space below. You will need this serial number when ordering parts, and when making technical or warranty inquiries. Frame serial number: Date purchased:...
  • Page 71: Carburetor Modification For High Altitude Operation

    TECHNICAL & CONSUMER INFORMATION Carburetor Modification for High Altitude Operation At high altitude, the standard carburetor air-fuel mixture will be too rich. Performance will decrease, and fuel consumption will increase. A very rich mixture will also foul the spark plug and cause hard starting. Operation at an altitude that differs from that at which this engine was certified, for extended periods of time, may increase emissions.
  • Page 72: Oxygenated Fuels

    TECHNICAL & CONSUMER INFORMATION Oxygenated Fuels Some conventional gasolines are being blended with alcohol or an ether compound. These gasolines are collectively referred to as oxygenated fuels. To meet clean air standards, some areas of the United States and Canada use oxygenated fuels to help reduce emissions.
  • Page 73: Emission Control System Information

    TECHNICAL & CONSUMER INFORMATION Emission Control System Information Source of Emissions The combustion process produces carbon monoxide, oxides of nitrogen, and hydrocarbons. Control of hydrocarbons and oxides of nitrogen is very important because, under certain conditions, they react to form photochemical smog when subjected to sunlight. Carbon monoxide does not react in the same way, but it is toxic.
  • Page 74 TECHNICAL & CONSUMER INFORMATION Problems That May Affect Emissions If you are aware of any of the following symptoms, have your engine inspected and repaired by your authorized Honda servicing dealer. Hard starting or stalling after starting. Rough idle. Misfiring or backfiring under load. Afterburning (backfiring).
  • Page 75: Air Index

    TECHNICAL & CONSUMER INFORMATION Air Index An Air Index Information hang tag/label is applied to engines certified to an emission durability time period in accordance with the requirements of the California Air Resources Board. The bar graph is intended to provide you, our customer, the ability to compare the emissions performance of available engines.
  • Page 76: Specifications

    TECHNICAL & CONSUMER INFORMATION Specifications EM5000is Dimensions Model (Type) Power product description code Length [Handle in up position] Width Height [Handle in up position] * Dry weight * Without battery Engine Model Engine Type Displacement Bore x Stroke Compression Ratio Engine Speed Cooling System Ignition System...
  • Page 77 TECHNICAL & CONSUMER INFORMATION EM7000is Dimensions Model (Type) Power product description code Length [Handle in up position] Width Height [Handle in up position] * Dry weight * Without battery Engine Model Engine Type Displacement Bore x Stroke Compression Ratio Engine Speed...
  • Page 78: Wiring Diagram

    TECHNICAL & CONSUMER INFORMATION Wiring Diagram...
  • Page 79: Consumer Information

    TECHNICAL & CONSUMER INFORMATION CONSUMER INFORMATION Honda Publications These publications will give you additional information for maintaining and repairing your generator. You may order them from your Honda generator dealer. Shop Manual This manual covers complete maintenance and overhaul procedures. It is intended to be used by a skilled technician.
  • Page 80: Customer Service Information

    TECHNICAL & CONSUMER INFORMATION Customer Service Information Honda Power Equipment dealership personnel are trained professionals. They should be able to answer any question you may have. If you encounter a problem that your dealer does not solve to your satisfaction, please discuss it with the dealership’s management. The Service Manager or General Manager can help.
  • Page 81: Assembly

    SAFETY The Importance of Proper Assembly Proper assembly is essential to operator safety and the reliability of the machine. Any error or oversight made by the person assembling and servicing a unit can easily result in faulty operation, damage to the machine, or injury to the operator.
  • Page 82: Important Safety Precautions

    ASSEMBLY Important Safety Precautions Make sure you have a clear understanding of all basic shop safety practices and that you are wearing appropriate clothing and safety equipment. When performing this assembly, be especially careful of the following: □ Read the instructions before you begin and be sure you have the tools and skills required to perform the tasks safely.
  • Page 83: Assembly

    ASSEMBLY Unpacking Remove the generator and loose parts box from the carton. Compare the loose parts with the inventory list below. Tools Required: 14 mm wrench (2), 10 mm wrench or Phillips head screwdriver for battery connections, pliers (not included) Loose Parts Check all loose parts against the following list.
  • Page 84: Wheel Kit Installation

    ASSEMBLY Wheel Kit Installation Do not operate the generator without the wheel kit installed. The wheel kit provides an air space between the ground and the generator air intake. If the wheel kit is not installed, it may be possible for dirt and debris to be drawn into the generator air intake causing possible generator damage.
  • Page 85: Handle Installation

    ASSEMBLY Handle Installation Install the handle assembly on the generator upper frame using the 12 mm washers, spring washers and handle holder bolts. TORQUE: 17 22 lbf·ft (24 29 N·m , 2.4 3.0 kgf·m) − − − HANDLE HOLDER BOLT (2) SPRING WASHER (2) 12 mm WASHER (2) HANDLE ASSEMBLY...
  • Page 86: Rear Bar Installation

    ASSEMBLY Rear Bar Installation Install the rear bar on the generator frame using the two 8 × 45 mm flange bolts. TORQUE: 17 22 lbf·ft (24 29 N·m , 2.4 3.0 kgf·m) − − − 8 45mm FLANGE BOLT (2) ×...
  • Page 87: Battery

    Battery The battery is either standard parts or optional parts for this generator. Battery: standard part WARNING: Battery posts, terminals and related accessories contain lead and lead compounds. The battery is disconnected and strapped into the battery tray for shipment. Remove the maintenance cover (see page Remove the battery strap from the bottom hook, and then remove the battery.
  • Page 88 ASSEMBLY Battery : optional part Part Number: 31500-MCR-D02 WARNING: Battery posts, terminals and related accessories contain lead and lead compounds. Remove the maintenance cover (see page Remove the battery strap from the bottom hook. Remove the red cable and the black cable from the twist clip, and set the battery.
  • Page 89: Engine Oil

    Engine Oil The generator is shipped WITHOUT OIL in the engine. Place the generator on a level surface. Add enough of the recommended oil to bring the oil level to the top of the oil filler neck. Use a 4-stroke motor oil that meets the requirements for API service classification SJ.
  • Page 90: Before Operation

    ASSEMBLY BEFORE OPERATION Before using your generator, you should become familiar with information contained in the following chapters and sections: GENERATOR SAFETY CONTROLS & FEATURES OPERATION (page STARTING THE ENGINE STOPPING THE ENGINE (page (page (page (page...
  • Page 91: Optional Parts

    Remote Control Kit Remove the maintenance cover (see page Remove the plug from the 6-pin connector. PLUG View the back of the maintenance cover and locate the knockout near the top center of the cover. Carefully remove the knockout. KNOCKOUT OPTIONAL PARTS MAINTENANCE COVER (backside)
  • Page 92 OPTIONAL PARTS Pass the remote control cable through the supplied wire grommet and fit the grommet into the maintenance cover knockout. Plug the remote control cable into the 6-pin connector. Install the maintenance cover and tighten the cover screw. REMOTE CONTROL CABLE REMOTE CONTROL CABLE REMOTE CONTROL BOX...
  • Page 93: Hanger Kit

    Hanger Kit Position the hanger at the generator’s balance point as shown below. Fit the end tabs of the hanger through the bracket slots, and bolt the brackets to the hanger and tighten securely. TORQUE: 17 22 lbf·ft (24 29 N·m , 2.4 3.0 kgf·m) −...
  • Page 94: Index

    INDEX AC Applications AC Circuit Protectors AC OPERATION AC Receptacle Selection AIR CLEANER SERVICE Air Index ARE YOU READY TO GET STARTED? ASSEMBLY Battery BATTERY SERVICE BEFORE OPERATION Carbon Monoxide hazards Carburetor Modification for High Altitude Operation Check the Engine Cleaning COMPONENT &...
  • Page 95 FEATURES Fire and Burn Hazards Folding Handle FOAM AIR FILTER CLEANING Fuel Fuel Gauge FUEL RECOMMENDATIONS Fuel Valve Lever FUSE GENERATOR PROBLEMS GENERATOR SAFETY Ground Terminal Handle Installation Hanger Kit Honda Publications i-Monitor IMPORTANT SAFETY INFORMATION Important Safety Precautions INDEX IS YOUR GENERATOR READY TO GO Knowledge Loose Parts...
  • Page 96 INDEX Maintenance Cover MAINTENANCE SAFETY MAINTENANCE SCHEDULE Oil Alert Indicator OPERATION Operator Responsibility OPTIONAL PARTS Output Indicator Overload Indicator Oxygenated Fuels QUICK REFERENCE INFORMATION Rear Bar Installation Ricoil Starter REFUELING Refuel With Care Remote Control Kit REMOVAL FROM STORAGE . 24 .
  • Page 97 SAFE OPERATING PRECAUTIONS SAFETY SAFETY LABEL LOCATIONS Safety Precautions SEDIMENT CUP CLEANING Serial Number Location SERVICING YOUR GENERATOR SPARK ARRESTER SERVICE SPARK PLUG SERVICE Special Requirements Specifications STAND BY POWER STARTING THE ENGINE STOPPING THE ENGINE STORAGE STORAGE PRECAUTIONS STORAGE PREPARATION System Ground TAKING CARE OF UNEXPECTED PROBLEMS TECHNICAL &...
  • Page 98 MEMO...
  • Page 99: Quick Reference Information

    QUICK REFERENCE INFORMATION Fuel Type Spark Plug Type Electrode Gap Battery Part Number Maintenance Before each use First 20 hours Subsequent Unleaded gasoline with a pump octane rating of 86 or higher NGK: BPR5ES DENSO: W16EPR-U 0.028 0.031 in (0.70 0.80 mm) −...
  • Page 100 31Z11603...

This manual is also suitable for:

Em5000is