Page 1
For model: 0916 0916 Smoke Alarm User’s Guide 9 Volt Battery Battery Operated Smoke Alarm with “HUSH” Control to temporarily silence nuisance alarms. Thank you for purchasing this smoke alarm. It is an important part of your family’s home safety plan. You can trust this prod- uct to provide the highest quality safety protection.
This alarm detects products of combustion using the ionization technique. It contains 0.9 microcurie of Americium 241, a radioac- tive material (see section 9). Distributed under U.S. NRC License No. 32-23858-01E. Manufactured in compliance with U.S. NRC safety criteria in 10 CFR 32.27. The purchaser is exempt from any regulatory requirements.
Page 3
• Locate an alarm in every room where electrical appliances are operated (i.e. portable heaters or humidifiers). • Locate an alarm in every room where someone sleeps with the door closed. The closed door may prevent an alarm not located in that room from waking the sleeper.
• Put smoke alarms at both ends of a bedroom hallway or large room if the hallway or room is more than 30 ft (9.1 m) long. • Install Smoke Alarms on sloped, peaked or cathedral ceilings at or within 3ft (0.9m)of the highest point (measured horizontally). NFPA 72 states: “Smoke alarms in rooms with ceiling slopes greater than 1 ft in 8 ft (.3m in 2.4m) horizontally shall be locat- ed on the high side of the room.”...
• In very humid areas. Moisture or steam can cause nuisance alarms. • In insect-infested areas. • Smoke alarms should not be installed within 3 ft (.9m) of the following: The door to a kitchen, the door to a bathroom con- taining a tub or shower, forced air supply ducts used for heating or cooling, ceiling or whole house ventilating fans, or other high air flow areas.
Page 6
1. Remove the mounting plate from the back of the alarm by hold- ing the mounting plate and twisting the alarm in the direction indicated by the “OFF” arrow on the alarm cover. 2. To insure aesthetic alignment of the alarm with the hallway or wall, the “A”...
NOTE: THE TAMPER RESIST PIN WILL HAVE TO BE REMOVED IN ORDER TO CHANGE THE BATTERIES. USE LONG NOSE PLI- ERS TO PULL THE PIN OUT OF THE HOLE. IT IS NOW POSSI- BLE TO REMOVE THE ALARM FROM THE MOUNTING PLATE. 8.
“OFF” arrow on the cover (see figure 7). The Model 0916 Smoke Alarm is powered by a 9V carbon zinc battery (alkaline and lithium batteries may also be used). A fresh battery should last for one year under normal operating condi- tions.
Alkaline type: ENERGIZER 522; DURACELL MN1604, MX1604; GOLD PEAK 1604A; PANASONIC 6AM6, 6AM-6, 6AM-6PI, 6AM6X, AND 6LR61 (GA) Lithium type: ULTRALIFE U9VL-J NOTE: WEEKLY TESTING IS REQUIRED. WARNING!! USE ONLY THE BATTERIES SPECIFIED. USE OF DIFFERENT BATTERIES MAY HAVE A DETRIMENTAL EFFECT ON THE SMOKE ALARM.
(associated with slow smoldering fires) sooner than ioniza- tion alarms. Home fires develop in different ways and are often unpredictable. For maximum protection, Kidde recommends that both Ionization and Photoelectric alarms be installed. • A battery powered alarm must have a battery of the specified type, in good condition and installed properly.
• Practice a fire drill at least every six months, including fire drills at night. Ensure that small children hear the alarm and wake when it sounds. They must wake up in order to execute the escape plan. Practice allows all occupants to test your plan before an emergency.
9. NRC INFORMATION Ionization type smoke alarms use a very small amount of a radioactive element in the sensing chamber to enable detection of visible and invisible combustion products. The radioactive element is safely contained in the chamber and requires no adjustments or maintenance.
If after reviewing this manual you feel that your smoke alarm is defective in any way, do not tamper with the unit. Return it for servicing to: KIDDE Safety, 1016 Corporate Park Dr., Mebane, NC 27302. 800-880-6788 (See Warranty for in-warranty returns).
(but not the battery) will be free from defects in material and workmanship or design under normal use and service for a period of five years from the date of purchase. The obligation of KIDDE Safety under this warranty is limited to repairing or replacing the smoke alarm...
Page 15
0916 Para el modelo: 0916 Guía del usuario de alarmas contra humo Alarma contra humo a batería de 9 voltios con control de silenciador, que permite silenciar temporalmente alarmas molestas. Gracias por comprar esta alarma contra humo, es parte importante del plan de seguridad de su hogar. Puede confiar en que este producto protegerá...
Page 16
Esta alarma detecta productos de combustión usando la técnica de ionización. Contiene 0.9 microcurios de americio 241, que es un material radiactivo (consulte la Sección 9). Se distribuye bajo licencia de NRC de EE.UU., Nº 32-23858-01E. Fabricada en conformidad con los criterios de seguridad de NRC de EE.UU. en 10 CFR 32.27. El comprador está...
Page 17
4 pulg. CIELORRASO (10 cm.) • Al instalar una alarma en el cielo raso, colóquela a una distancia mínima de 4 pulg. ESPACIO DE AIRE SIN CIRCULACIÓN (10 cm) de la pared lateral (consulte la Figura 1). MÍNIMO 4 pulg. •...
el extremo superior de la alarma a un mínimo de 4 pulg. (10cm) y un máximo de 12 pulg. (30,5cm) bajo el cielo raso (consulte la Figura 1). Si no está seguro de cuál es el aislamiento de su casa rodante, o si observa que las paredes externas y el cielo raso están calientes o fríos, instale la alarma en una pared interna.
Page 19
Al instalar la Al instalar la alarma alarma en un en la pared, la línea pasillo, la línea “A” debe estar “A” debe estar horizontal y la flecha paralela al pasillo. “UP FOR WALL MOUNTING” debe FIGURA 4 FIGURA 5 apuntar hacia arriba.
“OFF” en la cubierta (consulte la Figura 7). La alarma contra humo modelo 0916 usa una batería de carbón y cinc de 9 V (también se puede usar una batería de litio y alcalina). Una batería nueva debiera tener una duración de un año en condiciones normales de funcionamiento.
Page 21
(asociadas a incendios de expansión lenta) más rápido que las alarmas de ionización. Los incendios en las casas se pueden producir en diferentes formas y, con frecuencia, son impredecibles. Kidde recomienda que, para una máxima protección, se instalen alarmas de ionización y fotoeléctricas.
Page 22
baterías y los circuitos de alarma estén en buenas condiciones de funcionamiento. • Las alarmas contra humo no pueden dar la alarma si el humo no llega a ésta. Por lo tanto, es posible que estas alarmas no detecten incendios que se inicien en chimeneas, paredes, techos, al otro lado de una puerta cerrada o en otro piso.
12. SERVICIO Y GARANTÍA Si, después de revisar este manual, aún cree que su alarma contra humo está defectuosa, no la manipule. Devuélvala para su reparación a: KIDDE Safety, 1016 Corporate Park Drive, Mebane, NC 27302. 1-800-880-6788 (Consulte la Sección Garantía para obtener...
Page 24
La obligación de KIDDE Safety de acuerdo con esta garantía está limitada a la reparación o reemplazo, sin costos para el cliente, de la alarma contra humo o de cualquier pieza que esté...