Drain Connection; Electric Connection - Henny Penny HUMIDIFIED COUNTER WARMER HCS-2 Operator's Manual

Humidified counter warmer
Hide thumbs Also See for HUMIDIFIED COUNTER WARMER HCS-2:
Table of Contents

Advertisement

2-5. DRAIN CONNECTION

2-6. ELECTRIC CONNECTION

2-4
The drain can be connected to a 1 inch N.P.T. directly below the
water well or to a 3/4 inch N.P.T. from the operator's side. We
recommend the 1 inch N.P.T. connection as this will allow straight
down draining of the water.
The heated display cabinet is available from the factory wired for
208 or 230 volts, single phase, 3-wire (includes neutral) or three
phase, 4-wire (includes neutral) 50 or 60 Hz. service. The proper power
service cable must be provided at installation. Check the data plate
on the side panel of the control end to determine the correct power
supply.
To avoid electrical shock, the cabinet must be
adequately and safely grounded (earthed) according to
local electrical codes.
(FOR EQUIPMENT WITH CE MARK ONLY!)
To prevent electric shock hazard this appliance must be
bonded to other appliances or touchable metal surfaces
in close proximity to this appliance with an
equipotential bonding conductor. This appliance is
equipped with an equipotential lug for this purpose.
The equipotential lug is marked with the following
symbol
A separate disconnect switch with proper capacity fuses or
breakers must be installed at a convenient location between the
cabinet and the power source. The field supply wiring to the cabinet
should be an insulated copper conductor rated for 600 volts and
90°C.
Model HCS-2/HCW-3/HCW-5/HCW-8
1004

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hcs-5Hcw-8Hcw-2Hcw-3Hcw-5

Table of Contents