Heath Zenith Replacement Motion Sensor SH-5407 Owner's Manual

Heath Zenith Replacement Motion Sensor SH-5407 Owner's Manual

Replacement motion sensor
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Replacement
Motion Sensor
Model SH-5407
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight
hours.
• LED indicates motion was sensed (day or
night).
Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must
be wired through a switch.
• Some codes require installation by a qualifi ed
electrician.
OPERATION
Mode:
On-Time:
Works:
Day
Night
Test
5 Sec
x
x
Normal 1, 5, 10 min.
x
Manual
Until Dawn*
x
* resets to Auto Mode at dawn.
1
Note: When fi rst turned on wait about 1
/
minutes
2
for the circuitry to calibrate.
© 2007 HeathCo LLC
TEST
ON-TIME
Put the ON-TIME switch on the
bottom of the sensor in the TEST
position.
10 5 1 TEST
AUTO
ON-TIME
Put the ON-TIME switch in the 1,
5, or 10 minute position.
10 5 1 TEST
MANUAL MODE
Manual mode only works at night
because daylight returns the sen-
sor to AUTO.
Flip the light switch off for one
1 Second OFF
second then back on to toggle
then...
between AUTO and MANUAL
MODE.
Manual mode works only with
the ON-TIME switch in the 1, 5,
or 10 position.
... back on.
Mode Switching Summary
TEST
Move ON-TIME Switch
to 1, 5, or 10 minutes
AUTO
Flip switch off for
one second then
MANUAL MODE
back on*
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the
1
calibration time (1
/
min.) the control will be in the
2
AUTO mode.
598-1155-01

Advertisement

Table of Contents
loading

Summary of Contents for Heath Zenith Replacement Motion Sensor SH-5407

  • Page 1 Replacement Motion Sensor Model SH-5407 Features • Turns on lighting when motion is detected. • Automatically turns lighting off. • Photocell keeps the lighting off during daylight hours. • LED indicates motion was sensed (day or night). Requirements • The light control requires 120-volts AC. •...
  • Page 2: Installation

    INSTALLATION For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of elec- trical shock. For eave mount only: ❒ Swing the sensor head towards the clamp screw.
  • Page 3: Specifications

    ❒ Turn the RANGE control to the mid position and the ON-TIME control to the TEST position. ON-TIME ON-TIME RANGE 10 5 1 TEST 10 5 1 TEST MINUTES Bottom of Sensor Avoid aiming the control at: • Objects that change temperature rapidly, such as heating vents and air conditioners.
  • Page 4: Troubleshooting Guide

    TROUBLESHOOTING GUIDE SYMPTOM POSSIBLE CAUSE Lights will not 1. Light switch is turned off. come on. 2. Light is loose or burned out. 3. Fuse is blown or circuit breaker is turned off. 4. Daylight turn-off is in effect (recheck after dark).
  • Page 5 Repuesto Universal Para el Cabezal del Detector Modelo SH-5407 Características • Prende la luz cuando detecta movimiento. • Apaga la luz automáticamente. • La fotocélula mantiene la luz apagada durante el día. • LED indica que se ha detectado movimiento (durante el día o la noche).
  • Page 6: Prueba Y Ajuste

    INSTALACION Para instalarlo bajo el alero, la cabeza del detector debe ser girada como se muestra en los dos pasos siguientes para evitar el riesgo de un choque eléctrico. Sólo para montaje eléctrico: ❒ Gire la cabeza del detector hacia la unión del tornillo sujetador.
  • Page 7: Especificaciones

    ON-TIME ON-TIME RANGE 10 5 1 TEST 10 5 1 TEST MINUTES Parte de abajo del detector Evite apuntar el control hacia: • Objetos que cambien rápidamente de tem- peratura tales como ductos de calefacción y acondicionadores de aire. Estas fuentes de calor pueden causar falsas alarmas.
  • Page 8: Servicio Técnico

    GUIA DE INVESTIGACION DE AVERIAS SINTOMA POSIBLE CAUSA La luz no se enci- 1. El interruptor de luz está apagado. ende. 2. El faro está fl ojo o fundido. 3. El fusible está quemado o el cortacircuitos está apagado. 4. La desconexión de luz del día está en efecto.

This manual is also suitable for:

Secure home sh-5407

Table of Contents