OperatiOn
Mode:
On-Time
Works: Day Night
test
5 Seconds
x
x
security
1, 5 or 10 Minutes
x
manual
Until Dawn*
x
Override
* resets to Security mode at dawn.
Note: When first turned on wait about 1
/
minutes
1
2
for the circuitry to calibrate.
manuaL OverriDe mODe
Manual Override mode can only
be activated at night when the
ON-TIME switch is set to the 1,
5, or 10 minute position.
Flip the light switch off for one sec-
ond then back on to change from
1 Second OFF
SECURITY mode to MANUAL
then...
OVERRIDE mode.
To return to SECURITY mode,
either:
• turn the light off for one minute
then turn it on, or...
• daylight will automatically reset
... back on.
the light to SECURITY mode.
mODe sWitChing summary
TEST
ON-TIME Switch at 1, 5, or
10 minutes
SECURITY
AUTO
MODE
Flip light switch off
for one second then
MANUAL MODE
back on*
* If you get confused while switching modes, turn
the power off for one minute, then back on. After the
calibration time the control will be in the SECURITY
mode.
speCiFiCatiOns
Range ........................... Up to 70 ft.(21 m) [varies with
surrounding temperature].
Sensing Angle .............. Up to 180°
Electrical Load .............. Up to 300 Watt Maximum
Incandescent [Up to 150
Watt maximum each lamp
holder] or 10Watt Maximum
LED (Up to 5Watt Maximum
each lamp holder).
Bulb Type ...................... Up to 150 Watt Maximum
P A R 3 8
T u n g s t e n
Incandescent or 5Watt LED
model 2003LEDP38-65K.
Power Requirements .... 120 VAC, 60 Hz
Operating Modes .......... TEST, SECURITY, and
MANUAL OVERRIDE
ON-Timer ...................... 1, 5, 10 minutes
Test Timer ..................... 5 Seconds
Manual
Override Timer .............. Until Dawn
Range ........................... Adjustable
Page 4