Available languages

Quick Links

Motion Sensor
Decorative Lighting
Control
Model SL-5210
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Override, the control must be
wired through a wall switch.
• Some codes require installation by a qualified electrician.
• Switch Module mounts into a standard 4" x 4" junction box.
The SL-5210 package includes:
• The Sensor Module and Switch Module
• Three wire nuts
• Two sensor module screws
Typical Installation
Switch
Module In
Junction Box
Behind Light
Fixture
NOTE: The Drip Loop is neccessary to prevent rain from
running down the cord to the Sensor Module.
© 2003 DESA Specialty Products™
Features
Existing Light Fixture
Sensor Cord
Sensor Module
Drip Loop
OPERATION
Mode:
On-Time:
Test
5 Sec
Auto
1, 5, 10 min.
Manual
Until Dawn*
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
circuitry to calibrate.
Put the ON-TIME switch on the bottom of
the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5, or 10
minute position.
MANUAL OVERRIDE
Manual mode only works at night because
daylight returns the sensor to AUTO.
Flip the light switch off for one second then
back on to toggle between AUTO and
MANUAL MODE.
Manual mode works only with the ON-TIME
switch in the 1, 5, or 10 position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the power
off for one minute, then back on. After the calibration time
the control will be in the AUTO mode.
Works: Day
x
1
/
minutes for the
2
TEST
ON-TIME
10 5 1 TEST
AUTO
ON-TIME
10 5 1 TEST
1 Second OFF
then...
... back on.
Move ON-TIME Switch to
1, 5 or 10 minutes
Flip light switch off
for one second then
back on*
595-4991-06
Night
x
x
x

Advertisement

Table of Contents
loading

Summary of Contents for Heath Zenith DESA SPECIALTY PRODUCTSTM SL-5210

  • Page 1 Motion Sensor Decorative Lighting Control Model SL-5210 Features • Turns on lighting when motion is detected. • Automatically turns lighting off. • Photocell keeps the lighting off during daylight hours. Requirements • The Light Control requires 120-volts AC. • If you want to use Manual Override, the control must be wired through a wall switch.
  • Page 2: Installation

    INSTALLATION IMPORTANT: TURN OFF THE POWER TO THE LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX to avoid electrical shock. ❒ Remove the fixture and fixture strap (if present) and disconnect the wiring. Turn power off before wiring! Circuit Breaker Wire Connectors or Fuse...
  • Page 3: Specifications

    TEST AND ADJUSTMENT ❒ Turn on the circuit breaker and light switch. NOTE: Sensor has a 1 minute warm up period before it will detect motion. When first turned on or when switching modes, wait 1 ❒ Turn the SENSITIVITY (SENS) control to the mid position and the ON-TIME control to the TEST position.
  • Page 4: Troubleshooting Guide

    SYMPTOM POSSIBLE CAUSE Light will not 1. Light switch is turned off. come on. 2. Flood light is loose or burned out. 3. Fuse is blown or circuit breaker is turned off. 4. Daylight turn-off is in effect (recheck after dark) . 5.
  • Page 5 Control De Luz Decorativo Sensor De Movimiento Modelo SL-5210 Características • Prende la luz cuando detecta movimiento. • Apaga la luz automáticamente. • La fotocélula mantiene la luz apagada durante el día. Requisitos • El Control de Luz requiere 120 VCA. •...
  • Page 6 INSTALACION IMPORTANTE: Antes de empezar la instalación, APAGUE TODA LA CORRIENTE AL CIRCUITO DE LUZ EN EL ROMPECIRCUITO O CAJA DE FUSIBLES para evitar un choque eléctrico. ❒ Quite la lámpara y la cinta de montar, si alguna, y suelte el alambrado.
  • Page 7: Prueba Y Ajuste

    PRUEBA Y AJUSTE ❒ Prenda el cortacircuitos y el interruptor de luz. NOTA: El detector tiene un período de cerca de 1 de calentamiento antes de detectar movimiento. Cuando lo prenda por primera vez, espere 1 minutos. ❒ Gire el control de sensibilidad (SENS) a el medio, y el control de tiempo (ON-TIME) a la posición de prueba (TEST).
  • Page 8: Guia De Investigacion De Averias

    GUIA DE INVESTIGACION DE AVERIAS SINTOMA POSIBLE CAUSA La luz no se 1. El interruptor de luz está apagado. enciende. 2. El faro está flojo o fundido. 3. El fusible está quemado o el cortacircuitos está apagado. 4. La desconexión de luz del día está en efecto (Compruébelo al anochecer) .
  • Page 9 Commande de luminaire décoratif par détection de mouvement Modéle SL-5210 Caractéristiques • Allume l'appareil d'éclairage lorsqu'un mouvement est détecté. • Éteint automatiquement l'éclairage. • Photocellule qui maintient l'éclairage éteint pendant la période de lumière du jour. Exigences • La commande d'appareil d'éclairage requiert une source d'alimentation de 120 V c.a.
  • Page 10 INSTALLATION IMPORTANT: COUPER L'ALIMENTATION DU CIRCUIT D'ÉCLAIRAGE AU TABLEAU DES DISJONCTEURS OU DES FUSIBLES pour éviter les chocs électriques. ❒ Enlever le luminaire et la bride de connexion (si présente) et déconnecter le câblage. Couper l'alimentation avant de travailler sur le câblage! Tableau de disjoncteurs Serrae-fils...
  • Page 11: Fiche Technique

    ESSAI ET RÉGLAGE ❒ Ramener l'alimentation en circuit au tableau des disjoncteurs ou fusibles, et placer l'interrupteur d'éclairage sur «ON». REMARQUE: Le capteur doit se réchauffer 1 de pouvoir détecter le mouvement. Lorsque l’appareil est mis en circuit ou changé de mode, attendre 1 minute.
  • Page 12: Guide De Dépannage

    SYMPTÔME CAUSE POSSIBLE La lampe ne 1. L’interrupteur d’éclairage est en position hors circuit. s’allument 2. Les projecteurs sont brûlés ou desserrés. pas. 3. Le fusible du circuit a sauté ou le disjoncteur est en position hors circuit. 4. La fonction de mise hors circuit à la lumière du jour est engagée (Revérifier quand il fait nuit) .