Table of Contents

Advertisement

Quick Links

Installation &
Maintenance
English
EverSmart Scanners
www.creo.com/scanners
399Z50703F

Advertisement

Table of Contents
loading

Summary of Contents for Creo EverSmart

  • Page 1 Installation & Maintenance English EverSmart Scanners www.creo.com/scanners 399Z50703F...
  • Page 3: Fcc Compliance

    Copyright Copyright © 2002 Creo Inc. All rights reserved. No copying, distribution, publication, modification, or incorporation of this document, in whole or part, is permitted without the express written permission of Creo. In the event of any permitted copying, distribution, publication, modification, or incorporation of this document, no changes in or deletion of author attribution, trademark legend, or copyright notice shall be made.
  • Page 4 The text and drawings herein are for illustration and reference only. The specifications on which they are based are subject to change. Creo Inc. may, at any time and without notice, make changes to this document. Creo Inc., for itself and on behalf of its subsidiaries, assumes no liability for technical or editorial errors or omissions made herein, and shall not be liable for incidental, consequential, indirect, or special damages, including, without limitation, loss of use, loss or alteration of data, delays, or lost profits or savings arising from the use of this document.
  • Page 5: Table Of Contents

    Startup Sequence for EverSmart/EverSmart Pro ........
  • Page 6 EverSmart Scan Log Folder ........
  • Page 7 EverSmart Scanners Installation and Maintenance Appendix C Documentation Folder Documentation Folder ............130 C.1.1...
  • Page 9: About This Document

    EverSmart Scanners Installation and Maintenance About This Document This guide provides detailed instructions about how to install the EverSmart scanners properly, and maintain them in good operational condition. The procedures included in this guide are identical for the following scanner types: EverSmart, EverSmart Pro, EverSmart Pro II and EverSmart Supreme.
  • Page 10 About This Document Appendix A, Packing the Instructions on how to pack the scanner for transportation Scanner purposes. Appendix B, Technical Technical specifications. Specifications Appendix C, Documentation Instructions on how to use the documentation located on the folder application CD-ROM. Appendix D, Application Log Instructions on how to create application log files.
  • Page 11: Document Conventions

    EverSmart Scanners Installation and Maintenance Document Conventions The following conventions are used throughout this document: Item Purpose Example User interface elements, such as menu Select New from the File menu. User interface elements options and icons, are in bold. Click the Expand icon.
  • Page 13: Chapter 1 Site Preparation

    Chapter 1 Site Preparation General Requirements ......2 Safety Instructions......6...
  • Page 14: General Requirements

    Chapter 1 Site Preparation General Requirements This chapter describes the conditions that are necessary for proper EverSmart site preparation. Site Place the shipping package as close as possible to its final location. Before unpacking and installing the scanner, make sure the unpacking site is large enough to allow easy maneuvering.
  • Page 15: Scsi Cable

    SCSI cable supplied with the scanner. You can place the scanner up to six meters from the computer if you use longer cables. SCSI Boards The EverSmart scanners support the following SCSI boards: Adaptec 2903B Adaptec 2906 Adaptec 2930...
  • Page 16 10 cm 20 cm Scanner Figure 1. Scanner Location Macintosh Minimum System Requirements for EverSmart (Pro) Apple Power Macintosh with PCI bus. Apple Macintosh system software version 8.6 or higher. CD drive (required for software installation). 95 MB of available memory (RAM) for the scanning application, in addition to memory needed for the system software.
  • Page 17 155 MB of available memory (RAM) for the scanning application, in addition to memory needed for the system software. For EverSmart DOT application it is recommended to use a Macintosh G3 computer. 1 GB internal hard disk is recommended. Its capacity depends on your needs;...
  • Page 18: Safety Instructions

    Chapter 1 Site Preparation Safety Instructions To reduce the risk of electric shock, do not remove the cover. Refer servicing to qualified service personnel. This warning icon, which appears inside the scanner and in this manual, indicates that the scanner lamps are hot, and should not be handled before allowing them to cool off for several minutes.
  • Page 19: Chapter 2 Unpacking

    Chapter 2 Unpacking Unpacking Procedure ......8 Unlocking Screws & Removing Packing ... . 13...
  • Page 20: Unpacking Procedure

    Unpacking Procedure The first stage in the installation procedure is to unpack your EverSmart scanner, and place it on the table. This chapter describes how to open the package and unpack the scanner. Unpacking the scanner involves the following steps: Opening the box that contains the scanner.
  • Page 21 Unpacking Procedure 2. 2. 2. 2. Lift the upper cover protecting the scanner. 3. 3. 3. 3. Lift the carton carefully, straight upward from the scanner. Remove the transparent plastic wrapping of the scanner. 4. 4. 4. 4.
  • Page 22 Chapter 2 Unpacking 5. 5. 5. 5. Find the holding niche beneath the frame of the scanner (length-wise), carefully lift the scanner, and place it on the table. The scanner weighs approximately 70 kg / 156 lb, and two people are required to lift it.
  • Page 23 6. 6. 6. 6. Open the Installation Kit carton which contains everything required for proper scanner installation. To install the scanner, follow the instructions in the following chapters of this EverSmart Scanners Installation & Maintenance manual. (1) OP EN ME FIR ST Remove the accessory packages.
  • Page 24: Installation Kit (Required For Installation)

    CD containing computer based application training Mask kit User defined masks (10 pieces) 35-mm framed slide holders (2 pieces for EverSmart Pro/Supreme, 1 piece for EverSmart) 35-mm strip mask and mix format mask example (1 piece of each) The contents of the accessory packages may change from time to time.
  • Page 25: Unlocking Screws & Removing Packing

    Unlocking Screws & Removing Packing Unlocking Screws & Removing Packing A flat screwdriver is required for the procedures in this section. This tool is supplied with the installation kit. 1. 1. 1. 1. Open the top cover. You will find a sheet of paper with unlocking instructions.
  • Page 26 Chapter 2 Unpacking 2. 2. 2. 2. Insert the flat screwdriver in the niche of the screw located at the inside upper right corner of the top cover, push the screw inward, and turn the screw once, clockwise. Unlock Lock 3.
  • Page 27: Chapter 3 Powering On

    Chapter 3 Powering On Startup Sequence for EverSmart/EverSmart Pro ..19 Startup Sequence for EverSmart Pro II/EverSmart Supreme ........19...
  • Page 28: Powering On The Scanner

    Chapter 3 Powering On Powering on the Scanner This chapter explains how to power on your EverSmart scanner. To connect your EverSmart and power it on: Locate the power cable in the installation kit. 1. 1. 1. 1. The power cable is a North American type that complies with US and Canadian requirements.
  • Page 29 Powering on the Scanner 2. 2. 2. 2. Make sure that the scanner is switched OFF.
  • Page 30 Chapter 3 Powering On 3. 3. 3. 3. Connect the power cable to the power supply inlet located on the back panel. Connect the other end of the cable to a grounded electrical wall 4. 4. 4. 4. outlet. Switch the scanner ON. 5.
  • Page 31: Startup Sequence For Eversmart/Eversmart Pro

    If this step is completed successfully, the LED remains green. For EverSmart Pro scanners only - the Light button on the operating panel is used to switch the light table on and off, when the top cover of the scanner is open.
  • Page 32: Startup Troubleshooting

    The Status LED remains blinking green (missing software diagnostics, which may be loaded after installation; applies only to EverSmart (Pro) scanners). It is recommended to continue with the installation procedure even if one of these events occurs. If the installation procedure is terminated...
  • Page 33: Chapter 4 Software Installation

    Installation Procedure ......22 EverSmart Application Folder Contents ... . 26...
  • Page 34: Installation Procedure

    Chapter 4 Software Installation Installation Procedure The EverSmart software is provided on a CD located in the Installation kit package. To install the software: 1. 1. 1. 1. Insert the CD into the CD ROM drive, and double-click the EverSmart oXYgen/v.3.0 icon; the following window is displayed.
  • Page 35 Installation Procedure 2. 2. 2. 2. Double-click the EverSmart oXYgen/v.3.0 Inst icon in the window; the EverSmart Installer window is displayed: Click Continue; the EverSmart oXYgen/v.3.0 Inst window is 3. 3. 3. 3. displayed: In the scanner list, select your scanner.
  • Page 36 The counter shows the number of items that have been installed. 7. 7. 7. 7. As of EverSmart Scan software version 2.5.3, the software automatically installs the Adaptec SCSI Card 2906 driver. If the driver already exists, the following message is displayed.
  • Page 37 Installation Procedure 9. 9. 9. 9. When installation is complete, the following message window is displayed. Click OK. The scanner software is now installed, and the EverSmart oXYgen/v.3.0 folder is automatically displayed.
  • Page 38: Eversmart Application Folder Contents

    Chapter 4 Software Installation EverSmart Application Folder Contents EverSmart Scan Scanning application. EverSmart Install&Utils For scanner installation and automatic creation of tables. Scitex SCSI Information Shows which devices are connected to the SCSI bus. Calibration Slide.eps To be exposed to a film before starting any calibration procedures.
  • Page 39 EverSmart Application Folder Contents Service Applications Scanner Driver EverSmart Used by the scanning application. Intended for service engineers only. EverSmart Diag. EverSmart Calibration Intended for service engineers only. The software version appears in the title bar of the screen. Do not place...
  • Page 41: Chapter 5 Scsi Configuration

    Chapter 5 SCSI Configuration Configuration Options ......30 Setting the SCSI ID......43...
  • Page 42: Configuration Options

    Chapter 5 SCSI Configuration The next stage in the installation procedure is to connect your scanner to the computer. Important: Before connecting the scanner, make sure that the computer, the scanner, and all other devices are switched OFF. SCSI configuration involves the following steps: 1.
  • Page 43 Configuration Options 2. 2. 2. 2. From the installation kit, remove the SCSI cable, labeled as follows: SCSI cable (C50M/DB25M)
  • Page 44: Scsi Connector Location

    Chapter 5 SCSI Configuration 5.1.1 SCSI Connector Location The SCSI-related components on the scanner consist of the following: Two connector sockets A terminator switch A SCSI ID selector...
  • Page 45 Configuration Options Connector Sockets There are two connector sockets identified by the SCSI icon. The sockets are located on the SCSI connector panel on the back of the scanner, as shown in the following diagram. The connectors are connected in parallel, to enable a “daisy-chain” SCSI configuration.
  • Page 46 Chapter 5 SCSI Configuration Terminator Switch The last device on the SCSI chain requires a terminator. If the scanner is the last device on the SCSI chain, the terminator switch, located on the back panel of the scanner, should be switched ON, as shown in the following diagram.
  • Page 47: Scsi Board Installation (If Required)

    SCSI Board Installation (if required) SCSI Board Installation (if required) The next stage in the installation procedure is to connect the SCSI board to your computer. Consult your System Administrator before starting the SCSI board installation process. SCSI configuration involves the following steps: Before starting, switch OFF the computer, and disconnect the power cord.
  • Page 48 Chapter 5 SCSI Configuration 2. 2. 2. 2. Locate an unused PCI expansion slot (typically white or ivory) and remove the expansion slot cover screw. Then remove the expansion slot cover. Save the slot cover screw for use in Step 5. Expansion slot cover PCI Expansion...
  • Page 49 SCSI Board Installation (if required) 3. 3. 3. 3. Remove the SCSI board from its anti-static packaging. Always handle the board by its edges. Discharge any static electricity built-up before handling the SCSI board by touching a grounded metal object (like the exposed metal parts on the back of your computer).
  • Page 50 Chapter 5 SCSI Configuration 4. 4. 4. 4. Carefully insert the SCSI board into the PCI expansion slot, pressing it down firmly so the gold fingers are seated in the slot (see the figure in Step 3). Secure the SCSI board with the slot cover screw you removed in Step 3.
  • Page 51: Connecting Options

    Connecting Options Connecting Options Option 1: Scanner connected directly to computer RECOMMNEDED Connect the SCSI cable (1) from one of the scanner connector sockets to the SCSI board connector on the back panel of the computer. Switch the terminator ON.
  • Page 52 Chapter 5 SCSI Configuration Option 2: Scanner connected to computer through SCSI device NOT RECOMMENDED Connect the SCSI cable (1) from the peripheral device to the SCSI board connector on the back of the computer. Connect the peripheral vendor SCSI/SCSI cable from one of the connector sockets on the scanner to the peripheral device.
  • Page 53 Connecting Options Option 3: Scanner connected between the computer and SCSI device NOT RECOMMENDED Connect the SCSI cable (1) from one of the connector sockets on the scanner to the SCSI board connector on the back of the computer. Connect the peripheral vendor SCSI/SCSI cable from the other connector socket on the scanner to one of the ports on the peripheral device.
  • Page 54: Scsi Driver Installation

    If the SCSI Adapter CD is included in the kit, use it according to the manufacturer’s instructions. If not, please follow the instructions in the EverSmart Scanners Release Notes.pdf which you can find in the Release Documents folder. As of EverSmart Scan software version 2.5.3, the Install program automatically...
  • Page 55: Setting The Scsi Id

    Setting the SCSI ID Setting the SCSI ID The scanner has to be identified by the system; this is done by assigning the scanner a device identification number (ID). 1. 1. 1. 1. Switch ON the computer and all the SCSI devices. Rotate the SCSI ID selector on the back panel of the scanner, to the 2.
  • Page 56 Chapter 5 SCSI Configuration 5. 5. 5. 5. Double-click the Scitex SCSI Information icon located in the EverSmart oXYgen/v.3.0 folder. The SCSI network is scanned, and the network mapping is displayed, as shown in the following figure: All devices connected to the network appear as icons, together with their ID number.
  • Page 57: Chapter 6 Installation Program

    Chapter 6 Installation Program Stage 1 - Launch the Installation & Utilities Application 46 Stage 2 - Begin the Installation Procedure ..47 Stage 3 - Enter the Serial Number ....48 Stage 4 - Prepare the Scanner .
  • Page 58: Stage 1 - Launch The Installation & Utilities Application

    For partial installation (Custom Install), refer to 7.2 Custom Install on page 70. Stage 1 - Launch the Installation & Utilities Application Open the EverSmart oXYgen/v.3.0 application folder. Double-click the EverSmart Install&Utils icon; the EverSmart Installer flash screen is displayed.
  • Page 59: Stage 2 - Begin The Installation Procedure

    Stage 2 - Begin the Installation Procedure After a few seconds, the Installation & Utilities window is displayed. Stage 2 - Begin the Installation Procedure Click Continue; the EverSmart Installation window appears.
  • Page 60: Stage 3 - Enter The Serial Number

    8. 8. 8. 8. Click Install to continue with the installation. Stage 3 - Enter the Serial Number After a few seconds, the EverSmart Serial Number window is displayed. Enter the scanner serial number; the number appears in one of the...
  • Page 61 Stage 3 - Enter the Serial Number You must enter all the numbers and characters. However, the scanner recognizes the number with or without the slash and the final two digits.
  • Page 62 Chapter 6 Installation Program The scanner serial number on the calibration slide appears in the upper The scanner serial number on the calibration slide appears in the upper right corner, as shown in the following illustration: right corner, as shown in the following illustration.
  • Page 63: Stage 4 - Prepare The Scanner

    Stage 4 - Prepare the Scanner Stage 4 - Prepare the Scanner A message window is displayed, instructing you to clean the glass and place the calibration slide on the scanner. Prepare the cleaning kit and the calibration slide (in the Installation kit).
  • Page 64 Chapter 6 Installation Program Clean the base glass and upper glass plates. We recommend using domestic glass cleaning solution to clean all flat glass surfaces, as it leaves no trace after drying. The cleaning solution should not contain wax or ammonia. (Clear) Windex is recommended. Be sure not to pour cleaning solution directly on the glass, as it might leak inside.
  • Page 65 Stage 4 - Prepare the Scanner Place the calibration slide on the base glass: the pin holes in the slide should fit over the two right-hand pins at the top side of the base glass. The sticker on the calibration slide should be in the upper right-hand corner.
  • Page 66: Stage 5 - Automatic Diagnostics Check

    Chapter 6 Installation Program Stage 5 - Automatic Diagnostics Check An automatic diagnostics check is performed, and the following window is displayed with the results: The results can be either Passed or Fail. If all tests pass, the application automatically moves on to the next stage.
  • Page 67: Stage 6 - Automatic Optics Check

    Stage 6 - Automatic Optics Check Stage 6 - Automatic Optics Check An automatic Optics check is now performed, and the following message window is displayed with the test results. The results can be either Passed or Out of Tolerance. If the test passes, the application automatically moves on to the next stage.
  • Page 68: Stage 8 - Backup To Diskette Or External Media

    Chapter 6 Installation Program A fully automatic procedure for creating new machine tables is now performed. The duration of this procedure is approximately one hour, and a progress bar at the bottom of the screen shows the percentage of time that has elapsed. At the end of the tables, the parameters are automatically updated in the EverSmartScan.Prefs file, and saved back to the scanner.
  • Page 69 Stage 8 - Backup to Diskette or External Media You can choose where to save the parameters: Diskette, Jazz, Optical, etc. If you choose Diskette, first insert a new diskette (formatted or unformatted) into the disk drive. Do not use the backup diskette provided with the scanner.
  • Page 70: Stage 9 - Quit Installation

    Chapter 6 Installation Program Insert a diskette; a message window is displayed confirming that the saving has been successfully completed. Click Done; the following message is displayed. Click Done to return to the Installation&Utilities window. Stage 9 - Quit Installation After the tables are copied to the media, a message window is displayed confirming that the installation has been successfully completed.
  • Page 71: General Tips

    Results of the installation procedure are written to the file Install&Util_results_file in the log folder. Refer to EverSmart Scan Log Folder on page 79 for more details. General Tips To make the most of your EverSmart and its capabilities, we suggest...
  • Page 72: Troubleshooting For The Installation & Utilities Program

    Chapter 6 Installation Program 6.10 Troubleshooting for the Installation & Utilities Program Problem Description and Solution on page... Serial Number Mismatch Serial Number Mismatch (second time) Wrong Media Inserted SCSI Communication Failure Diagnostics Check Failure Calibration Slide Incorrectly Placed Optics Check: Out of Tolerance 6.10.1 Serial Number Mismatch Problem If there is a mismatch between the serial number on the scanner label,...
  • Page 73: Serial Number Mismatch (Second Time)

    Troubleshooting for the Installation & Utilities Program Solution Check the number carefully, enter it into the edit box, and click Confirm. 6.10.2 Serial Number Mismatch (second time) Problem If the number entered still does not match, a message window is displayed on the screen requesting you to insert the scanner parameters backup media.
  • Page 74 Chapter 6 Installation Program Solution An original, factory-produced, parameters backup media is supplied with the scanner. The media is located in the Installation kit. Insert this media into the drive. If no parameter media exists, click No Backup; default parameters are automatically created.
  • Page 75: Wrong Media Inserted

    Troubleshooting for the Installation & Utilities Program 6.10.3 Wrong Media Inserted Problem If the backup media also has a serial number mismatch, or a wrong media has been inserted, a message window is displayed requesting you to insert the correct media. Solution If no other parameter media exists, click No backup;...
  • Page 76: Diagnostics Check Failure

    Chapter 6 Installation Program Solution Click Stop to quit the Installation & Utilities program. Switch OFF the scanner and the computer. Check all SCSI connections: cables, terminators, and configuration. For more details, refer to SCSI Communication Problems on page 112. Run the Installation &...
  • Page 77: Calibration Slide Incorrectly Placed

    Troubleshooting for the Installation & Utilities Program Solution Click Continue to continue with the installation program. If the Continue button is disabled, click Quit to exit to the main screen, and contact your service center. 6.10.6 Calibration Slide Incorrectly Placed Problem The scanner verifies that the calibration slide has been placed on the scan carriage, and is inserted correctly.
  • Page 78: Optics Check: Out Of Tolerance

    Chapter 6 Installation Program 6.10.7 Optics Check: Out of Tolerance Problem During the Optics check, an Out of Tolerance notice is displayed. Solution In this case, the previously generated tables remain intact. New tables will not be generated. Click Continue to display the following message window: Click Stop to return to the main window.
  • Page 79: Chapter 7 Utilities

    Backup Parameters......77 EverSmart Scan Log Folder ..... 79...
  • Page 80 The program contains the following utility options: Performing a partial (custom) installation Scanner check Creating scanner tables Using the backup media The utilities are described in the following sections. The EverSmart Scan log folder is described in Section 7.6 EverSmart Scan Log Folder on page 79.
  • Page 81: Status Screen

    Status Screen Status Screen While a utility program is running, you can view the progress of the process, by selecting the Show Status option from the Windows menu, in Menu bar. After you select the Show Status option, the following window is displayed.
  • Page 82: Custom Install

    The Custom Install utility is used to perform a partial scanner installation. To perform a custom installation, perform the following: 1. 1. 1. 1. Double-click the EverSmart Install&Utils icon. In the window that is displayed, select the Installation Program option. 2. 2. 2. 2. Click Continue.
  • Page 83 Select one or more options, and click Install. The stages that you selected are executed automatically. Results file Upon completion of the Custom Install, the results are written to the file Install&Util_results_file. For an explanation of this file, refer to EverSmart Scan Log Folder on page 79.
  • Page 84: Scanner Checks

    You are required to activate this utility only when a scanner operational problem arises. To activate this utility: 1. 1. 1. 1. Double-click the EverSmart Install&Utils icon. In the window that is displayed, select Scanner Checks. 2. 2. 2. 2. Click Continue; a message window is displayed instructing you to clean the glass and place the calibration slide on the scanner.
  • Page 85 If an error occurs during the Diagnostics or the Optics check, 5. 5. 5. 5. in the error message that is displayed, click Continue. Test results are written to a results file described EverSmart Scan Log Folder on page 79.
  • Page 86: Create Tables

    Upon completion of the Scanner Checks, the results are written to the file Install&Util_results_file. For an explanation of this file, refer to EverSmart Scan Log Folder on page 79. Create Tables This option is used when tables need to be created.
  • Page 87 Create Tables 2. 2. 2. 2. Click Continue; the following window is displayed. You have four options in the Create Tables options list: Create All (the default option) Cast Removal Factors Enlargement < 1000% Enlargement > 1000% Select the desired option, and click Activate. A message window is displayed instructing you to clean the glass and place the calibration slide on the scanner.
  • Page 88 At the end of the process, the following completion message is displayed. Results file Upon completion of the table creation procedure, the results are written to the file Install&Util_results_file. For an explanation of this file, refer to EverSmart Scan Log Folder on page 79.
  • Page 89: Backup Parameters

    EverSmartScan.Prefs file is erased or becomes corrupted. save the parameters from the computer to a Backup Media. 1. 1. 1. 1. Double-click the EverSmart Install&Utils icon. In the window that is displayed, select Backup Parameters.
  • Page 90 At the end of the process, a completion message is displayed on the screen. Results file Upon completion of the backup procedure, the results are written to the file Install&Util_results_file. For an explanation of this file, refer to EverSmart Scan Log Folder on page 79.
  • Page 91: Eversmart Scan Log Folder

    When you run the scanner application from the folder created during installation, the EverSmart Scan Log folder is automatically created in the same folder. All log files are written to this log folder. If, for any reason, you moved the application, a new EverSmart Scan Log folder is created in the new location.
  • Page 93: Chapter 8 Maintenance

    Chapter 8 Maintenance Replacing the Transparency Lamp ....83 Replacing the Reflective Lamps ....88 Replacing the Light Table Lamps .
  • Page 94: Lamp Replacement

    The scanner operates with the following fluorescent lamps: one transparency lamp two reflective lamps two light table lamps (in EverSmart Pro, EverSmart Pro II & EverSmart Supreme) Replace the lamps when: the light level is too low (a message is displayed). This applies to the transparency and reflective lamps.
  • Page 95: Replacing The Transparency Lamp

    Lamp Replacement 8.1.1 Replacing the Transparency Lamp The transparency fluorescent lamp is located inside the scanner top cover. Light level is too low The following message is displayed on the screen. To exit the message window, perform one of the following: Click Abort;...
  • Page 96 Chapter 8 Maintenance Replacement Procedure To replace the transparency lamp perform the following: Switch OFF the main power switch of the scanner. The transparency lamp is hot. Wait a few minutes for the lamp to cool off before replacing it. 1.
  • Page 97 Lamp Replacement 2. 2. 2. 2. Unscrew the four screws at the upper and lower corners of the top cover. After several rotations, the screws spring out of their sockets. There is no need to remove the screws. 3. 3. 3. 3. Close the top cover.
  • Page 98 Chapter 8 Maintenance 4. 4. 4. 4. Remove the top cover by gripping it at two diagonal corners, and lifting it. After the top cover is removed, the transparency lamp is visible.
  • Page 99 Lamp Replacement 5. 5. 5. 5. Remove the transparency lamp in two steps. First, gently pull one end of the lamp inward. Then, lift out the other end. 6. 6. 6. 6. Insert a new transparency lamp. Make sure that you insert the lamp 7.
  • Page 100: Replacing The Reflective Lamps

    Chapter 8 Maintenance 9. 9. 9. 9. Open the top cover. Screw the four screws at the upper corners of the top cover. Switch the scanner ON, and verify that the new lamp illuminates after a few seconds. 8.1.2 Replacing the Reflective Lamps The reflective lamps are located beneath the glass plate.
  • Page 101 Lamp Replacement Replacement Procedure To replace the reflective lamp, perform the following: Switch the scanner ON; after a few seconds, the Status LED is 1. 1. 1. 1. green. 2. 2. 2. 2. Open the top cover. 3. 3. 3. 3. Press the Light button on the front panel for approximately 20 seconds;...
  • Page 102 Chapter 8 Maintenance 4. 4. 4. 4. Unscrew the four screws that fasten the glass plate to the scanner. The screws should be rotated 90 counterclockwise. Closed Open Lift the two handles of the glass plate. 5. 5. 5. 5.
  • Page 103 Lamp Replacement 6. 6. 6. 6. Pull out the glass plate. 7. 7. 7. 7. Place the glass plate on a soft surface.
  • Page 104 Chapter 8 Maintenance 8. 8. 8. 8. Remove the lamp in two steps. First, gently push the lamp inward. 9. 9. 9. 9. Then, lift the lamp out of the tray.
  • Page 105 Lamp Replacement Insert a new lamp, making sure that the lamp window faces upwards and inwards. Reflective lamp alignment Always replace both reflective lamps, even if only one is faulty. Lift the plate glass up (using the handles) and place it back in its original position (on the scanner frame).
  • Page 106: Replacing The Light Table Lamps

    Chapter 8 Maintenance 8.1.3 Replacing the Light Table Lamps (for EverSmart Pro, EverSmart Pro II and EverSmart Supreme) The light table lamps are located beneath the light table plate. The light table lamps switch on when the top cover is opened, and you press the Light button.
  • Page 107 Lamp Replacement Replacement Procedure To remove the front panel of the scanner, do the following: Remove the base glass. 1. 1. 1. 1. Refer to Replacing the Reflective Lamps on page 88. 2. 2. 2. 2. Through the handle opening closest to the front panel side, open the screw connecting the center of the front panel.
  • Page 108 Chapter 8 Maintenance 3. 3. 3. 3. Unlock the following three rotating locks: two on the left side of the panel (from the front of the scanner). one at the middle of the bottom of the panel, on the inner side.
  • Page 109 Lamp Replacement 4. 4. 4. 4. Pull out the left side of the panel.
  • Page 110 Chapter 8 Maintenance 5. 5. 5. 5. Slide out the right side of the panel.
  • Page 111 Lamp Replacement 6. 6. 6. 6. To release the light table plate, open the light table plate clamp. 7. 7. 7. 7. Lift the plate out through the front panel opening. Make sure not to damage the flat cable while pulling out the plate.
  • Page 112 Chapter 8 Maintenance 8. 8. 8. 8. Remove the light table lamps by rotating them and gently pulling them out of their holders. When you assemble the light table lamp plate after replacing the lamps, make sure that the plate is inserted properly into the correct pin slots.
  • Page 113: Cleaning The Glass

    Cleaning the Glass Cleaning the Glass The upper and base glass plates require periodic cleaning. We recommend using domestic glass cleaning solution to clean all flat glass surfaces, as it leaves no trace after drying. The cleaning solution should not contain wax or ammonia. (Clear) Windex is recommended. Do not pour cleaning solution directly on the glass, as it may leak under the glass surfaces.
  • Page 114: Upper Glass Cleaning

    Chapter 8 Maintenance 8.2.1 Upper Glass Cleaning Switch OFF the main power switch of the scanner. The transparency lamp is hot. Wait a few minutes for the lamp to cool off. 1. 1. 1. 1. Lift up the top cover. Place a cardboard on the glass plate to prevent damaging the glass during this procedure.
  • Page 115 Cleaning the Glass 2. 2. 2. 2. Unscrew the four screws at the upper and lower corners of the top cover. After several rotations, the screws spring out of their sockets. There is no need to remove the screws. 3. 3. 3. 3. Close the top cover.
  • Page 116 Chapter 8 Maintenance 4. 4. 4. 4. Remove the top cover by holding it firmly at two diagonal corners, and lifting it. Clean the glass plate surface. 5. 5. 5. 5.
  • Page 117: Base Glass Cleaning

    Cleaning the Glass 8.2.2 Base Glass Cleaning Switch OFF the main power switch of the scanner. The lamps in the lamp tray are hot. Wait a few minutes for the lamps to cool off. Unscrew the four screws that fasten the glass plate to the scanner. 1.
  • Page 118 Chapter 8 Maintenance 2. 2. 2. 2. Lift the two handles of the glass plate. 3. 3. 3. 3. Pull out the glass plate.
  • Page 119 Cleaning the Glass 4. 4. 4. 4. Place the glass plate on a soft surface. 5. 5. 5. 5. Clean the base glass surface, making sure you do not touch the white sticker running along the side of the glass. White Sticker After you clean the glass, hold the handles firmly, and place the 6.
  • Page 121: Chapter 9 General Troubleshooting

    Chapter 9 General Troubleshooting Power & Self-Tests ......110 SCSI Communication Problems ....112 Scanning Quality.
  • Page 122: Power & Self-Tests

    Symptom The Status LED on the operating panel is red. Suggestions Switch the scanner OFF, then ON. After 30 seconds (in EverSmart Pro II and EverSmart Supreme, approximately after 15 seconds), verify that the Status LED is a constant green.
  • Page 123 Suggestions This event occurs when one of the scanner safety switches is activated. Switch the scanner OFF, then ON. After 30 seconds (in EverSmart Pro II and EverSmart Supreme, approximately after 15 seconds), verify that the Status LED is a constant green.
  • Page 124: Scsi Communication Problems

    The scanner does not appear in the SCSI chain in the SCSI Information panel. Suggestions Switch the scanner OFF, then ON. After 30 seconds (in EverSmart Pro II and EverSmart Supreme, approximately after 15 seconds), verify that the Status LED is a constant green.
  • Page 125 Scanning Quality Suggestions Run the Scanner Check procedure from the Installation & Utilities application (refer to Scanner Checks on page 72). Verify that all the tests pass. Run the Create Tables procedure from the Installation & Utilities application (refer to Create Tables on page 74). Perform a scan, and compare the results with the defective scan.
  • Page 126: Scanner/Application Hangs

    Status LED is a constant green. If the Status LED blinks green for more than 30 seconds, or remains red, call your service center. (In EverSmart Pro II and EverSmart Supreme, if the Status LED remains red, call your service center.)
  • Page 127 Illumination Problems Symptom Light table lamps do not light up (EverSmart Pro, EverSmart Pro II & EverSmart Supreme). Suggestions Perform the following steps: Switch the scanner OFF, and then ON and wait until the Status LED is a constant green.
  • Page 129: Appendix A Packing The Scanner

    Appendix A Packing the Scanner Locking the Scanner ......118 Packing the Scanner......121...
  • Page 130: Locking The Scanner

    Packing the Scanner Locking the Scanner This appendix provides instructions on how to pack the scanner when it is necessary to transport it from one location to another. 1. 1. 1. 1. Switch the scanner OFF. 2. 2. 2. 2. Rotate the SCSI selector on the back of the scanner to position number 8.
  • Page 131 Locking the Scanner 4. 4. 4. 4. Press the Light button on the operator panel, and wait 5 seconds for the carriage to move to the locking position, on the right side of the scanner. 5. 5. 5. 5. Insert the flat screwdriver in the niche of the screw located at the inside upper right corner of the top cover, push the screw inward, and turn the screw once, counter-clockwise.
  • Page 132 Packing the Scanner 6. 6. 6. 6. Insert the flat screwdriver in the niche of the screw located on the right hinge of the top cover, and turn the screw once, clockwise. Unlock Lock...
  • Page 133: Packing The Scanner

    Packing the Scanner Packing the Scanner 1. 1. 1. 1. Place the accessory packages on the wooden palette.
  • Page 134 Packing the Scanner 2. 2. 2. 2. Find the holding niche beneath the frame of the scanner (length-wise), carefully lift the scanner, and place it on the wooden palette. Make sure to place the scanner on the four bumpers located at the four corners of the palette, and according to the markings on the bumpers.
  • Page 135 Packing the Scanner 3. 3. 3. 3. Place the carton carefully over the scanner. 4. 4. 4. 4. Insert the four foam corners in the space between the scanner corners and the outer carton (these are required to prevent movement of the scanner).
  • Page 136 Packing the Scanner 5. 5. 5. 5. Place the upper cover protecting the scanner. 6. 6. 6. 6. Close the top cover and tape the carton. 7. 7. 7. 7. Use straps to attach the wooden palette to the carton.
  • Page 137: Appendix B Technical Specifications

    Appendix B Technical Specifications...
  • Page 138 Illumination Sampling Accuracy 14 bits/pixel: EverSmart (Pro)/EverSmart Pro II 16 bits/pixel: EverSmart Supreme Max Density 4.0 D Max: EverSmart (Pro)/EverSmart Pro II 4.3D Max: EverSmart Supreme Optic Resolution 5600 DPI /220 DPM (EverSmart Supreme) (over the Entire Scanner 3150 DPI /125 DPM (EverSmart Pro/EverSmart...
  • Page 139: Electrical Requirements

    Features Background scanning application (EverSmart Pro, EverSmart Pro II and EverSmart Supreme) Autofocus on picture Batch scanning Built-in light table (EverSmart Pro, EverSmart Pro II and EverSmart Supreme) Registration pins SCSI Interface Electrical Requirements Input Power Voltage 100 - 240 VAC, 50/60 Hz – voltage selection is...
  • Page 141: Appendix C Documentation Folder

    Appendix C Documentation Folder Documentation Folder......130 System Requirements for Using the Documentation . 131 Installing Adobe Acrobat Reader on Macintosh ..132 Using Adobe Acrobat Search Function.
  • Page 142: C.1 Documentation Folder

    Documentation Folder Documentation Folder This appendix lists the contents of the EverSmart Doc folder located on the EverSmart oXYgen/v.3.0 application CD-ROM. The documents are in Adobe Acrobat PDF file format, so you need to install Adobe Acrobat Reader version 3.0. Installation instructions are included in this appendix.
  • Page 143: C.1.1 System Requirements For Using The Documentation

    Documentation Folder The EverSmart Scanners folder contains the following files and subfolders: The ReadMe file (in three languages) that contain the contents of this document The PDF folder that contains the Readme file, and all the manuals in PDF format The Reader folder that contains the Reader and Search folders The manuals are in Adobe Acrobat PDF file format.
  • Page 144: C.1.2 Installing Adobe Acrobat Reader On Macintosh

    1. 1. 1. 1. The first time you use the search index, you will need to add the 2. 2. 2. 2. EverSmart Jazz to the index list. To do so, select Indexes. 3. 3. 3. 3. Select Add. 4. 4. 4. 4.
  • Page 145: Appendix D Application Log Files

    Appendix D Application Log Files...
  • Page 146 Select the Create Scanner Driver Log File check box. 3. 3. 3. 3. Continue scanning. After the final scan, the application log files will be created in the EverSmart Scan_Log Folder. Send the created EverSmart Scan_Log Folder to your service 4.
  • Page 147: Appendix E Catalog Numbers

    Appendix E Catalog Numbers...
  • Page 148 Mask pack, Mix format (5 pieces) 509D1L517 Mask pack, 35 mm strip (5 pieces) 509D1L495 Lamps Scanning lamp (1 piece) 139H00035 Light table lamp (1 piece) 139H15004 EverSmart Scanning Solutions Training Package 513K1M947* EverSmart Scanners Scanning Solutions User Guide 399Z1P555* (English) Image Correction Examples 399Z50389*...
  • Page 149 French 501V50762* German Optional: EverSmart DOT for EverSmart Pro 510K51177 EverSmart DOT for EverSmart Pro II & EverSmart 510K51893 Supreme Oil Mounting Station 510B44937 A star ( ) that appears after the catalog number indicates a version. When you place an order for an item, please make sure to ask for the latest update.
  • Page 151: Index

    EverSmart Scanners Installation and Maintenance Index calibration slide inserting, 53 loading, 72 acoustic noise level, 127 misplaced, troubleshooting, 65 activating scanner check, 72 serial number location, 48, 50 Adobe Acrobat Reader calibration slide, Important notice, 59 installing, 132 card installation, See board...
  • Page 152 Scan.Prefs file, 56 location, 79 Scan_Log Folder, 79 scanner check results, 74 software, 22 table creation results, 76 EverSmart Scanners folder, 131 Install&Utils program EverSmartScan.Prefs file, scanner parameters, 48 creating tables, 74 external media, backing up to, 57 scanner checks, 72...
  • Page 153 EverSmart Scanners Installation and Maintenance lamp location operating temperature, 127 light table lamp, 94 optic resolution, 126 reflective lamp, 88 optics check transparency lamp, 83 automatic, 55 lamp not lit, troubleshooting, 83 out of tolerance,troubleshooting, 66 lamp replacement options, table creation, 75...
  • Page 154 Index requirements SCSI electrical, 2 bus, 43 general, 2 cable, 3, 31 minimum system, 4 SCSI boards, 3 system, 5 installation, 35 resolution, optic, 126 installation, Warning notice, 35 Results file, 71, 74, 76 SCSI communication results, installation, 59 failure, troubleshooting, 63 running scanner check, See activating scanner problems, troubleshooting, 112 check...
  • Page 155 EverSmart Scanners Installation and Maintenance table creation, options, 75 vertical lines, troubleshooting, 112 table, supporting, 2 voltage, 2, 16, 127 tables backing up, 56 creating, 55, 74 technical specifications, 126 warning messages temperature, 2 troubleshooting, 114 operating, 127 weight, 2, 127...

Table of Contents