Download Print this page

Hearth and Home Technologies WSK100 Installation And Operating Instructions

Hearth and home technologies wall switches installation and operating instructions

Advertisement

Quick Links

WSK100, WSK200 and WSK210 Wall Switches
CAUTION
DO NOT DISCARD THIS MANUAL
Important installation and operation instruc-
tions included.
Read, understand and follow these
instructions for safe installation and
operation.
Leave this manual with party responsible
for use and operation.
INTRODUCTION
The WSK100 and WSK200 wall switches are designed to
switch the fi replace on or off, and the pilot function activates
the pilot fl ame as well. These wall switches interface with
Intellifi re
systems only.

INSTALLATION PRECAUTIONS

This wall switch is tested and safe when installed in
accordance with this installation manual. Do not install
any components that may be damaged. Do not modify,
disassemble, or substitute any of the components included
with this kit. Installation of this unit must be done by a
qualifi ed service technician.
Placement of this wall switch may affect performance. An
assessment of the space should be done prior to installation
for optimum performance. See Section 1.1 for location
recommendations.
NOTE: The electrical junction box provided with the fi replace
must be wired with 110 VAC before installing this kit. See
owner's manual for details.
NOTE: All wiring should be done by a qualifi ed electrician and
shall be in compliance with local codes and with the National
Electric Code ANSI/NFGA No. 70 - current (in the United
States), or with the current CSA C22.1 CANADIAN ELECTRIC
CODE (in Canada).
WARNING
Shock Risk
Do NOT provide any power to this unit
until all wiring is complete.
May destroy parts of this device and
render it unusable.
May lead to possible electrical shock.
- Installation and Operating Instructions -
1
WARNING
Inspect components for damage. Damaged
parts may impair safe operation.
• Do NOT install damaged components.
• Do NOT install incomplete components.
• Do NOT install substitute components.
Report damaged parts to dealer.
Wall Switch
Control Box
Figure 1. Items included in the WSK100 Wall Switch Kit
Wall Switch
Control Box
Figure 2. Items included in the WSK200 and WSK210 Wall Switch
Kit. (Delay circuit not shown).
Printed in U.S.A.
Copyright 2007
Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
Wiring Harness
Wiring Harness
2050-910G 7/07

Advertisement

loading

Summary of Contents for Hearth and Home Technologies WSK100

  • Page 1: Installation Precautions

    May lead to possible electrical shock. - Installation and Operating Instructions - Wall Switch Figure 1. Items included in the WSK100 Wall Switch Kit Wall Switch Figure 2. Items included in the WSK200 and WSK210 Wall Switch Kit. (Delay circuit not shown).
  • Page 2: Installation Instructions

    fi replace. Never place this unit in a separate room. The distance from the fi replace to the switch may be up to 50 ft. The switch should be mounted into a UL-listed electrical junction box.
  • Page 3 IPI MODULE USED (7) 12" WIRES BUNDLED MINIMUM SEE DETAIL A - A FOR WSK210 DETAIL J-BOX (110V) Figure 3. IPI wiring diagram with WSK100, WSK200 and WSK210 Wall Switch PILOT BATTERY PACK WALL SWITCH WSK-100/200 CONTROL BOX WSK210 ONLY ON/OFF...
  • Page 4: Operation Instructions

    fl ame off and has battery backup. The fi replace will shut down and the display lights in the wall switch will be off. When the power is restored to the system, the display lights will remain unlit and the fi replace will remain off.

This manual is also suitable for:

Wsk200Wsk210