Quadra-Fire CB1200-B Installation And Operation Manual Page 2

Hearth & home technologies classic bay 1200 pellet stove owner's manual installation and operation.
Hide thumbs
R
CB 1200 Pellet Stove
!
and Welcome to the Quadra-Fire Family
of our stoves, inserts and fireplaces. And yet we are old-
Hearth & Home Technologies welcomes you to our tradi-
fashioned when it comes to craftsmanship. Each unit is
tion of excellence! In choosing a Quadra-Fire appliance,
meticulously fabricated and surfaces are hand-finished for
you have our assurance of commitment to quality, durabil-
lasting beauty and enjoyment. Our pledge to quality is com-
ity, and performance.
pleted as each model undergoes a quality control inspec-
This commitment begins with our research of the market,
tion.
From design, to fabrication, to shipping:
including 'Voice of the Customer' contacts, ensuring we
We wish you and your family many years of enjoyment in
make products that will satisfy your needs. Our Research
the warmth and comfort of your hearth appliance. Thank
and Development facility then employs the world's most
you for choosing Quadra-Fire.
advanced technology to achieve the optimum operation
SAMPLE SERIAL NUMBER / SAFETY LABEL LOCATION:
Behind left side curtain on outside of hopper wall.
CAUTION:
HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS. Operate this unit with fuel hopper lid closed. Failure to do so may result in emissions
products' combustion from the hopper under certain conditions. Maintain hopper seal in good condition. Do no over fill the hopper.
ATTENTION:
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE
Testing Lab &
CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS. Opérez cet appareil avec le couvercle de la trémie fermé. Le défaut de ne
pas suivre les instructions peut résulter, sous certaines conditions, en une combustion des émissions des produits venant de la trémie. Ne pas remplir la trémie trop pleine.
Report Number
SERIAL NO. / NUMÉRO DU
Tested and
Portland
Report / Rapport
O-T L
R
007C
Listed by
Oregon USA
CB 1200 Pellet Stove
C
US
061-S-21-4
OMNI-Test Laboratories, Inc.
Listed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for Mobile Home Installation. This appliance has
Appareil de chauffage inséré de combustible solide/de type de boulettes. Accepté dans l'installation dans les maisons mobiles. Cet
been tested and listed for use in Manufactured Homes in accordance with OAR 814-23-9000 through 814-23-909.
appareil a été testé et enregistré pour l'usage dans les Maisons Mobiles en accord avec OAR 814-23-9000 jusqu'à 814-23-909.
Tested to: ASTM E1509-95, ULC/ORD-C-1482-M1990, ULC S627-M93 Room Heating Pellet Burning Type,
Testé à: ASTM E1509-95, ULC/ORD-C 1482-M1990, ULC S627-M93 Room Heating. Pellet Burning Type, APFI, (UM)
APFI, (UM) 84-HUD FOR USE ONLY WITH PELLETIZED WOOD OR SHELLED FIELD CORN FUEL.
84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS OU DE COMBUSTIBLE DE MAIS ÉCOSSÉ DES CHAMPS.
Serial Number
Puissance de Rendement: 40,000 Btu's/hr
Input Rating: 40,000 Btu's/hr
Puissance Électrique: 115 VAC, 60 Hz, Début 4.6 Amps, Courir 1.6 Amps,
Electrical Rating: 115 VAC, 60 Hz, Start 4.6 Amps, Run 1.6 AMPS.
Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil.
Route power cord away from unit. Do not route cord under or in front of appliance.
DANGER: Il y a risque de décharge électrique. Déconnectez le fil électrique de la prise de contact avant le service.
DANGER: Risk of electrical shock. Disconnect power supply before servicing. Replace glass only with 5mm
Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur.
ceramic available from your dealer. To start, set thermostat above room temperature, the stove will light
Pour allumer, monter la température du thermostat au dessus de la température de la pièce, le poêle s'allumera
automatically. To shutdown, set thermostat to below room temperature. For further instruction refer to owner's
automatiquement. Pour éteindre, descendre la température du thermostat en dessous de la température de la pièce. Pour des
manual.Keep viewing and ash removal doors tightly closed during operation.
Model
instructions supplémentaires, référez vous au manuel du propriétaire. Gardez la porte d'ouverture et la porte des cendres
fermées hermétiquement durant l'opération.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS /
ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:
A
Back Wall to stove / Mur Arrière du poêle
2"/51mm
C
E
A
D
A
C
C
B
Side Wall to Cast Top / Mur De Côté du haut
6"/152mm
CORNER INSTALLATION / NSTALLATION DU COIN :
C
Side Wall / Mur De Côté
2"/51mm
B
B
B
C
E
VERTICAL ADAPTER KIT INSTALLATION:
UN ASSEMBLAGE POUR ADAPTEUR POUR INSTALLATION VERTICALE:
D
Back Wall to Flue Pipe / Mur Arrière tuyau rigide
3"/76
mm
Note 1: In residential installations, when using Parts 811-0580, (3" - 3" Top Vent Adapter) and
B
Side Wall to Cast Top / Mur De Côté du haut
6"/152mm
812-2690 (3" - 6" Top Vent Adapter Collar) 24 gauge 6" single wall flue connector may be used.
F
CORNER INSTALLATION WITH VERTICAL ADAPTER KIT:
D
Note 1:
INSTALLATION DU COIN AVEC UN ASSEMBLAGE D'ADAPTEUR VERTICAL:
Dans les installations résidentielles, lorsque les pièces 811-0580, (dessus de l'adapteur de
ventilation 3" - 3") et 812-2690 (collier de l'adapteur de ventilation 3" - 6"), un tuyau connecteur de 6"
E
Side Wall / Mur De Côté
2"/51mm
pour mur simple de calibre 24 peut être utilisé.
INSTALLATION DE L' ALCÔVE:
ALCOVE INSTALLATION /
Max. Alcove Depth: / La profondeur maximum de l'alcôve
36"/914mm
A
Note 2:
In manufactured home installation, when using Part 811-0580, (3" - 3" Top Vent Adapter) and
A
Back Wall to stove / Mur Arrière du poêle
2"/51mm
812-2690 (3' - 6" Top Vent Adapter Collar), use listed double wall flue connector. An Outside Air Kit
B
Side Wall to Cast Top / Mur De Côté du haut
6"/152mm
(Part 811-0560 rear or 811-0570 floor), must be used with manufactured home installation.
C
Unit corner to diagonal wall /
2" (51mm)
F
Top of Unit to Combustibles / Du poêle du haut combustibles
12.5"/318mm
Note 2:
Pour l'installation dans les maisons préfabriquées, lorsque les pièces 811-0580 (dessus de
Alcove vertical installation / Installation verticale de l'alcôve
l'adapteur de ventilation 3" - 3") et 812-2690 (collier de l'adapteur de ventilation 3" - 6"), utilisez un
D
Back Wall to Flue Pipe / Mur Arrière tuyau rigide
mm
3"/76
tuyau connecteur enregistré pour mur double. Un assemblage d'air extérieur (pièce 811-0560 arrière
au 811-0570 la plancer), doit être utilisé pour l'installation dans les maisons préfabriquées.
FLOOR PROTECTION / PROTECTION DU SOL
H*
*Non-combustible floor protection must extend beneath the flue pipe when installed with
*Un protecteur incombustible de plancher doit s'étendre sous le conduit de cheminée pour une
horizontal venting or under the Top Vent Adapter with vertical installation.
installation de ventilation horizontale ou sous un adapteur de ventilation de dessus pour une
G
G
RECOMMENDED IN USA; REQUIRED IN CANADA
installation verticale. ÉTATS-UNIS - RECOMMANDÉ; CANADA - REQUIRENT
I
Floor protector must be noncombustible material, extending beneath heater and to the
Le poêle doit être placé sur une assise non combustible s'étendant tout autour de lui, comme les
schémas l'indiquent. Mesurez la distance du devant (I) de la surface de la porte vitrée.
front/sides/rear as indicated. Measure front distance (I) from the surface of the glass door.
G = 2"/51mm
H* = 2"/51mm
U.S. ENVIRONMENTAL PROTECTION AGENCY This model is exempt from EPA certification under 40 CFR 60.531 by definition [Wood Heater (A) "Air-to-Fuel Ratio"].
I = 6"/152mm
2008
2009
2010
JAN
FEB
MAR APR MAY
JUNE JULY AUG
SEPT OCT
NOV DEC
Mfg Date
1445 Highway North
Colville, WA 99114
www.quadrafire.com
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
Made in China/Fait Aux Chine
7014-079
Page 2
7014-082D
September 1, 2008