Jøtul GF 100 DV II Nordic QT; GF 200 DV II Lillehammer Installation And Operation Instructions Manual

Jøtul GF 100 DV II Nordic QT; GF 200 DV II Lillehammer Installation And Operation Instructions Manual

Direct vent gas stove

Advertisement

WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or loss of life.
– Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
– Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
– In the Commonwealth of Massachusetts,
a carbon monoxide (CO) detector shall be
installed in the same room as the appliance.
This appliance may be installed in an aftermarket,
permanently located, manufactured home or mobile
home, where not prohibited by local codes.
This appliance is only for use with the types of gas
indicated on the rating plate. A conversion kit is
supplied with the appliance.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Installation and

Operation Instructions

ATTENTION : CES INSTRUCTIONS DOIVENT
DEMUERER AVEC LE PROPRIÉTERE D'UNE
MAISON.
AVERTISSEMENT: Assurez-vous de bien suiv-
reles instructions données dans cette notice
pour réduire auninimum le risque d'incendie
ou d'explosion ou pour éviter tout dommage
matériel, toute blessure ou la mort.
– Ne pas entreposer ni utiliser d'essence ni
d'autres vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout
autre appareil.
– QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE
GAZ:
• Ne pas tenter d'allumer l'appareil.
• Ne touchez à aucum interrupteur. Ne pas
vous servir des téléphones se trouvant dans
le bâtiment où vous trouvez.
• Appelez immédiatement votre fournis-
seur de gaz depuis un voisin. Suivez les
instructions du fournisseur.
• Si vou ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies.
– L'installatione l'entretien doivent être
assurés par un installateur ou un service
d'entretien qualifié ou par le fournisseur de
gaz.
138003_Rev_K / 7.29.10
1

Advertisement

Table of Contents
loading

Summary of Contents for Jøtul GF 100 DV II Nordic QT; GF 200 DV II Lillehammer

  • Page 1: Operation Instructions

    138003_Rev_K / 7.29.10 Installation and Operation Instructions WARNING: If the information in these ATTENTION : CES INSTRUCTIONS DOIVENT instructions is not followed exactly, a fire DEMUERER AVEC LE PROPRIÉTERE D’UNE or explosion may result causing property MAISON. damage, personal injury or loss of life. AVERTISSEMENT: Assurez-vous de bien suiv- reles instructions données dans cette notice –...
  • Page 2 138003_Rev_K / 7.29.10 WARNING THIS PRODUCT MUST BE INSTALLED BY A LICENSED MASTER OR JOURNEYMAN PLUMBER OR GAS-FITTER WHEN INSTALLED IN THE COMMONWEALTH OF HOT GLASS WILL MASSACHUSETTS. CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN We recommend that TO TOUCH GLASS.
  • Page 3: Table Of Contents

    138003_Rev_K / 7.29.10 Table of Contents Jøtul GF 100 DV II Nordic QT Jøtul GF 200 DV II Lillehammer Specifications, Jøtul GF 100 DV II ..4 Direct Vent Gas Heaters Specifications, Jøtul GF 200 DV II ..5 General Information ........6 Manufactured and Distributed by: Jøtul North America Service Tools ..........6...
  • Page 4: Specifications, Jøtul Gf 100 Dv Ii

    138003_Rev_K / 7.29.10 Jøtul GF 100 DV II Nordic QT Specifications 21” 533 mm Input Rates Natural Gas 17,000 BTU/hr. maximum input 22 1/4” 9,900 BTU/hr. minimum input 565 mm Propane 16,000 BTU/hr. maximum input 8,700 BTU/hr. minimum input Inlet Pressure: Natural Gas: 5.0 WC (1.24 kPa) 7.0 WC (1.74 kPa) Propane:...
  • Page 5: Specifications, Jøtul Gf 200 Dv Ii

    138003_Rev_K / 7.29.10 Jøtul GF 200 DV II Lillehammer Specifications 24 3/4” Input Rates 630 mm Natural Gas 20,000 BTU/hr. maximum input 11,400 BTU/hr. minimum input Propane 22 3/4” 18,000 BTU/hr. maximum input 560 mm 8,450 BTU/hr. minimum input Inlet Pressure: Natural Gas: 5.0 WC (1.24 kPa) 7.0 WC (1.74 kPa) Propane:...
  • Page 6: General Information

    138003_Rev_K / 7.29.10 General Information Stove Setup THIS HEATER MUST BE INSTALLED AND MAINTAINED BY  Inspect the stove for damage and contact your dealer im- A QUALIFIED SERVICE AGENCY. mediately if any is found. Check contents of the Miscella- neous Kit against the lists on p.
  • Page 7: Safety Information

    138003_Rev_K / 7.29.10 Location children and other at-risk individuals out of the room and away from hot surfaces. In selecting a location for the stove, consider the fol-  Any safety screen or guard removed for servicing lowing points: an appliance must be replaced prior to operating 1) Heat distribution the appliance.
  • Page 8: Clearances

    138003_Rev_K / 7.29.10 Stove and Vent Clearance Max. Mantel Depth 11.5” Requirements 9.5” 7.5” 5.5” Min. Mantel Minimum Clearances from the Stove to Combustibles: Depth Measured from the stove top plate. See figs. 2-4. Max. Top Trim For Both Stoves Depth = 1”...
  • Page 9: Vent Requirements Adding Restriction

    138003_Rev_K / 7.29.10 Venting Requirements Intake Air Restriction Both stoves may be installed with a vertical or horizon- tal termination and must conform to the configuration You may need to restrict air intake to the burner, depend- requirements described in this section. This appliance is ing on the stove vent configuration.
  • Page 10: Vertical Termination

    138003_Rev_K / 7.29.10 Vertical Vent Termination 15 Ft. The Jøtul GF 100 DV II and Jøtul GF 200 DV II are approved (457.2 cm) for vertical venting through a ceiling or to a roof termina- tion following these guidelines: The termination should fall within the shaded area of ...
  • Page 11 138003_Rev_K / 7.29.10 High Wind Exhaust Gas Venting Through a Fireplace Intake Air Max. Co-linear Co-linear Vent Installation Height 15 ft. This appliance may be vented through a masonry or Class (10.66 m) A prefabricated chimney using a Co-linear Flexible Vent Min.
  • Page 12: Horizontal Termination

    138003_Rev_K / 7.29.10 Horizontal Vent Termination Wall Cut-out Opening: A minimum 10" X 10"  (250 mm x 250 mm) square hole is required for proper pipe clearances through a combustible wall. Use one of the approved vent manufacturers’ WALL THIMBLE for the wall penetration.
  • Page 13 138003_Rev_K / 7.29.10 Max. 4 ft. Horizontal Wall Thimble and Trim Collar Wall Shield Installation The decorative Wall Shield, included in the Miscellaneous Hardware bag, is used to obscure the vent hole in the wall in installations vented directly off the rear of the stove. Max.
  • Page 14: Vent Terminal Clearances

    138003_Rev_K / 7.29.10 Horizontal Termination Clearance Figure 17. Vent Terminal Clearances - National Fuel Gas Code. A = Clearance above grade, veranda, porch , deck, or meter/regulator assembly within 3 feet (90 cm) hori- balcony : 12 inches (30 cm) minimum. zontally from the center-line of the regulator.
  • Page 15: Mobile Home Installation

    138003_Rev_K / 7.29.10 Mobile Home Installation Fuel Conversion These appliances can be installed for use in a mobile Your gas stove is shipped from the factory equipped to home in the U.S. and Canada provided: burn NATURAL GAS only. If PROPANE gas is to be used as fuel, the appliance must first be converted for use with 1.
  • Page 16 138003_Rev_K / 7.29.10 Gas Conversion Procedure 1. Turn off gas supply to stove. critical to proper function. Be certain that the burner plate is securely engaged with the support brackets. 2. Remove the stove Top Plate (3). 16. Replace the burner skirt. 3.
  • Page 17: Gas Supply Connection

    138003_Rev_K / 7.29.10 Gas Supply Connection NOTE: If the optional Blower will be installed, use a 90° Pilot Head Elbow off the valve to create adequate clearance for the Orifice main gas line. The gas supply line connection is made to the valve just Retainer inside the left rear leg.
  • Page 18: Gas Pressure

    138003_Rev_K / 7.29.10 High Altitude Adjustment Gas Pressure The decreased atmospheric pressure of higher altitudes Correct gas pressure is essential for efficient and safe op- affects heat value of gaseous fuels. Most gas suppliers eration. It is important that the correct pressure is estab- derate the gas intended for use at elevations above 2000 lished at the time of the installation.
  • Page 19: Air Shutter Adjustment

    138003_Rev_K / 7.29.10 Flame Appearance - Air Shutter Adjustment WARNING: AIR SHUTTER ADJUSTMENTS SHOULD ONLY High Altitude Orifice Chart BE PERFORMED BY A QUALIFIED PROFESSIONAL SERVICE Jøtul GF 200 DV II Only TECHNICIAN. The air shutter setting at the burner orifice can be adjust- Orifice Elevation Fuel...
  • Page 20: Wall Thermostat

    138003_Rev_K / 7.29.10 Optional Wall Thermostat or Log Set Installation Remote Control NOTE: Install the optional Brick Kit, if appropriate, before Use only a 750 millivolt DC two-wire circuit thermostat installing the Log Set. See page 30. with this appliance. The thermostat should be placed in the same room as the heater, typically 5 feet off the The Log Set and Ember Stones are packaged in foam floor.
  • Page 21: System Check

    138003_Rev_K / 7.29.10 System Check 1” 1. PURGING THE GAS LINE: When lighting the appliance (25mm) for the first time, it will take a few moments to clear 3/8” 1/8” (8mm) the gas line of air. Once this purge is complete, the (3mm) Min.
  • Page 22: Operation

    138003_Rev_K / 7.29.10 Operation Familiarize yourself with the controls of your stove. Make sure that anyone else using the appliance is also familiar with the controls and operation procedures. Always follow the Lighting Instructions on the inside back cover of this manual and also located on the Rating Plate attached to the burner assembly.
  • Page 23 138003_Rev_K / 7.29.10 Glass and Gasket Replacement Enamel Care and Maintenance Only Use Replacement Kit 155599. 1. Use a small screwdriver to pry the four retainer clips • Do not attempt to clean hot enamel surfaces. Clean off of the glass frame. See fig. 33. only cold surfaces with a soft damp cloth and polish with a clean dry cloth.
  • Page 24: Optional Blower

    138003_Rev_K / 7.29.10 Optional Blower # 155631 Contents Tools Required 1. Blower • 1/4” socket driver CONNECT THE GAS SUPPLY TO THE 2. Snapstat Wire Harness • 10 mm socket STOVE BEFORE INSTALLING THIS 3. Control Box driver or wrench BLOWER.
  • Page 25: Blower Operation

    138003_Rev_K / 7.29.10 Figure 37 . Attach Blower to the stove bottom and connect wires to Snapstat. Mounting Bracket for GF100 DV II Snapstat Connectors #8 x 1/2” sheet M6 x 20 mm metal screws Hex Bolts GF 100 DV II: First install the Mounting Bracket to the holes in the bottom of the rear shroud using two BLOWER #8 x 1/2”...
  • Page 26 138003_Rev_K / 7.29.10 GF 100 DV II / GF 200 DV II Figure 39.
  • Page 27 138003_Rev_K / 7.29.10 Parts List - GF 100 DV II / GF 200 DV II Firebox Assembly Part Description Part Number Part Description Part Number Rear Shroud, Matte Black ....22055592 Middle Log ..........221105 Rear Shroud, Jøtul Iron ....22055585 Rear Log, (two-piece) ......221104 Burner Control Switch ......129123 Log Set w/ Embers .........
  • Page 28: Illustrated Parts Breakdown

    138003_Rev_K / 7.29.10 Illustrated Parts Breakdown / Cast Iron and Associated Hardware Jøtul GF 100 DV II Nordic QT Figure 40 . Jøtul GF 200 DV II Lillehammer Figure 41.
  • Page 29 138003_Rev_K / 7.29.10 Cast Iron Parts List Jøtul GF 100 DV II Nordic QT Cast Iron Parts Matte Black Blue Black Ivory Green Jøtul Iron Jøtul Iron Majolica Majolica Paint Enamel Enamel Enamel Paint Enamel Brown Enamel Blue Enam- Top Casting 10391092 10391027 10391029...
  • Page 30: Addendum - Brick Panel Kit

    138003_Rev_K / 7.29.10 CAUTION! Tools Required: Safety glasses and gloves THE BRICK PANELS ARE EXTREMELY FRAGILE. HAN- DLE WITH CARE. WEAR SAFETY GLOVES TO PROTECT HANDS. Upper Panel 221117 Left Panel Right Panel 221114 221115 1. Remove the Top Plate. Simply lift it up off of the stove body.
  • Page 31: Warranty Statement

    138003_Rev_K / 7.29.10 Jøtul Gas Product Limited Warranty 3) Damage due to service performed by an installer, service agency or gas This warranty policy applies to gas products identified supplier, unless otherwise agreed to in writing by JØTUL. by Jøtul, Scan, and Atra trade names, as set forth below. 4) Labor or other costs associated with the repair of gas controls, A.
  • Page 32 138003_Rev_K / 7.29.10 This page is intentionally blank.
  • Page 33 138003_Rev_K / 7.29.10 This page is intentionally blank.
  • Page 34 138003_Rev_K / 7.29.10 This page is intentionally blank.
  • Page 35: Lighting Instructions

    LIGHTING INSTRUCTIONS 138003_Rev_K / 7.29.10 FOR YOUR SAFETY, READ BEFORE LIGHTING. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUS- ING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. A. This appliance has a pilot which must be lit •...
  • Page 36 138003_Rev_K / 7.29.10 This appliance must be installed in conformance with local and national building regulations. Before beginning the installation, it is important that the these instructions be carefully read and understood. Jøtul maintains a policy of continual product development. Consequently, products may differ in speci- fication, color or type of accessories from those illustrated or described in various publications.