Mantel And Wall Projections - Heat & Glo SLR (Cosmo) Owner's Manual

Installation and operation
Hide thumbs Also See for SLR (Cosmo):
Table of Contents

Advertisement

D. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).
Combustible Mantels
1/2 in.
Thick Wall
12 in.
Sheathing
MAX.
14 in.
MEASUREMENT FROM TOP OF
MIN.
FIREPLACE OPENING
Figure 5.3 Clearances To Combustible Mantels Or Other
Combustibles Above Appliance
Non-combustible Mantels
1/2 in.
Thick Wall
12 in.
Sheathing
MAX.
MEASUREMENT
14 in.
FROM TOP OF
MIN.
FIREPLACE
OPENING
Figure 5.4 Clearances To Non-Combustible Mantels Or Other
Non-Combustibles Above Appliance
Note: For non-combustible fi replace fi nish mate-
rial (marble, stone, etc) specifi cations refer to Figure
13.13 and Figure 13.15.
Combustible Mantel Legs Or Wall Projections
Extending Past The Face Of The Fireplace
2 IN.
3 FT. MAXIMUM
MINIMUM
6 IN.
MINIMUM
Figure 5.5 Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
Non-combustible Mantel Legs Or Wall Projections
Extending Past The Face Of The Fireplace
3 IN.
UNLIMITED
MINIMUM
Figure 5.6 Non-Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
Front Side Finishing Detail
1.00 in.
FRAMING
1-9/16 in.
1/2 in. BUILDING MATERIAL
Figure 5.7 Front Side Finishing Detail
Page 19

Hide quick links:

Advertisement

Table of Contents
loading