Lennox Hearth Products Elite EDVI25 Installation Instructions Manual
Lennox Hearth Products Elite EDVI25 Installation Instructions Manual

Lennox Hearth Products Elite EDVI25 Installation Instructions Manual

Elite series direct-vent gas fireplace heater inserts
Hide thumbs Also See for Elite EDVI25:

Advertisement

Report No. 116-F-14-5
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other fl ammable
s or liquids in the vicinity of this or any other
appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow your gas suppliers
instructions.
• If your gas supplier cannot be reached, call
the fi re department.
Installation and service must be performed by a
qualifi ed installer, service agency or the gas sup-
plier
.

INSTALLATION INSTRUCTIONS

DIRECT-VENT GAS FIREPLACE HEATER INSERTS
Elite™ Series, Models: EDVI25, EDVI30 & EDVI35
Suitable for installation into masonry or factory built fi replaces.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
P/N 775,156M Rev. G, 3/2005
These appliances may be installed in an aftermarket permanently located,
manufactured (mobile) home, where not prohibited by local codes.
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE
POUR RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE
OU POUR ÉVITER TOUT DOMMAGE MATÉRIEL,
TOUTE BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser
d'essence ni d'autre vapeurs ou liquides infl ammables dans
le voisinage de cet appareil ou de tout autre appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une
odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment où vous
vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
L'installation et service doit être exécuté par un qualifi é
installeur, agence de service ou le fournisseur de gaz.
MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products Elite EDVI25

  • Page 1: Installation Instructions

    INSTALLATION INSTRUCTIONS MANUAL DIRECT-VENT GAS FIREPLACE HEATER INSERTS Elite™ Series, Models: EDVI25, EDVI30 & EDVI35 Suitable for installation into masonry or factory built fi replaces. RETAIN THIS MANUAL FOR FUTURE REFERENCE P/N 775,156M Rev. G, 3/2005 Report No. 116-F-14-5 These appliances may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes.
  • Page 2: Table Of Contents

    fi red heater. It is our goal at Lennox Hearth Products to provide you, our valued customer, with an appli- Installation must conform to local codes. In ance that will ensure you years of trouble free warmth and pleasure.
  • Page 3: General Information

    Feet (meters) inspection should be performed by a qualifi ed PROVIDED IN THIS DOCUMENT WILL RESULT 0-4500' service person. It is imperative that the control EDVI25 IN AN IMPROPERLY INSTALLED AND OPERAT- (.096") (.0595") (0-1370 meters) compartment, burner and circulating air pas- ING APPLIANCE, VOIDING ITS WARRANTY.
  • Page 4: High Altitude

    FIREPLACE REQUIREMENTS QUESTIONS TO ASK LOCAL BUILDING 6. Maximum amount of gas pipe without a OFFICIAL pressure test - type of test required? IMPORTANT: When installing these appliances 7. Are below grade penetrations of the gas These appliances must be installed per into a factory built fi...
  • Page 5: Specifi Cations

    SPECIFICATIONS: EDVI25 DIMENSIONS SPECIFICATIONS EDVI25 EDVI25 Inches (millimeters) Min. / Max. BTU hr 17,000 to 25,000 26 5/8" (676 mm) Input - NG 20 1/2" (521 mm) Min. / Max. BTU hr 19,000 to 25,000 5” (127 mm) Input - LP SM.= 41 1/16”...
  • Page 6 SPECIFICATIONS: EDVI30 & EDVI35 DIMENSIONS SPECIFICATIONS EDVI30 EDVI35 EDVI30 EDVI35 Inches (millimeters) Inches (millimeters) Min. / Max. BTU/hr 21,500 to 30,000 25,500 to 35,000 25 15/16" (659 mm) 32 1/16” (814 mm) Input - NG 22 1/4" (578 mm) 24 3/16” (614 mm) Min.
  • Page 7: Clearance To Combustibles

    MINIMUM CLEARANCES TO COMBUSTIBLES: EDVI25, EDVI30 & EDVI35 These appliances can be installed in most residential fi replace confi gurations. If installed close to an adjacent Inches (millimeters) wall, ensure that the minimum clearances to combustible Clearances to Combustibles Min.
  • Page 8: Step 1 Clean Fireplace

    (see Figure 10) and lift it off of fi rebox top. the appliance at step 9 (page 11). Set door aside in a safe place. Inches (millimeters) Min. Fireplace Suggested Sizing of Black Iron Pipe Clearance EDVI25 EDVI30 EDVI35 Schedule 40 - Pipe Supply Line Dimensions 22" 25"...
  • Page 9 Collinear Direct-Vent components may be safely used with these appli- connection is required (to ances (see Figures 14 & 15). ensure com- Masonry and Factory bustion air is Lennox Hearth Products – Collinear Direct-Vent Kits drawn down Built Fireplaces the chimney only). Cat. No. Model...
  • Page 10 Factory Built Fireplace Installation Diagram Masonry Fireplace Installation Diagram The standard cap in Termination Kit, H0908, is a high wind cap Vertical Term- Masonry chimneys may take ination Cap various contours which the Vertical Termination Cap and Flashing. fl exible liners will accomodate. and Flashing, Cat.
  • Page 11: Step 9 Connect Gas Line

    The millivolt control valve has a 3/8" are located within the fi rebox of the insert. (10 mm) NPT thread inlet port fi tting. Note: The EDVI25/EDVI30 log set is shown Gear Clamp in fi gures 20-28 and the EDVI35 log set is...
  • Page 12 LOGS, VERMICULITE AND EMBERS - Models EDVI25 & EDVI30 (For 3. Place the Center Log onto the 2 corresponding locating pins as shown in Figure 22. EDVI35 Log Installation Instructions, see Page 13). The packaged log set, vermiculite and embers are located within the fi...
  • Page 13 Figure 25 Front Center Log 7. Install the Top Right Log into the corresponding indentations on Embers Figure 27 Front Center Log and front right twig as shown in Figure 26. Figure 28 Vermiculite Figure 26 Top Right Log LOGS, VERMICULITE AND EMBERS - Model EDVI35 8.
  • Page 14 Rear Log Front Center Log Figure 32 Figure 29 Vermiculite 6. Install the Top Right Log into the corresponding indentations on Front Center Log and Front Right Log as shown in Figure 33. 3. Place the Front Right Log and the Center Left Log onto the 2 cor- responding locating pins (each) as shown in Figure 30.
  • Page 15: Control Kit

    Proper Pilot Flame Appearance E. Turn on gas supply and test for gas leaks using Thermocouple a soapy water or gas leak detection solution. MODEL EDVI25 Igniter Rod " Min Never use an open fl ame to check for leaks.
  • Page 16 Fan Disc appliance inside surfaces and on exterior Natural Gas 3/16" (4.76 mm) EDVI25 surfaces adjacent to the vent termination. Propane 3/8" (9.52 mm) Sooting is caused by incomplete combus- 5/16" (7.94 mm) Natural Gas tion in the fl...
  • Page 17 SAFETY / LISTING LABELS - MODELS: EDVI30 & EDVI35 MODEL NO. EDVI30 MODEL NO. EDVI35 MANUFACTURED AT: Union City, TN MANUFACTURED AT: Union City, TN FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL ALTITUDE 0-4500 FT/PI ALTITUDE...
  • Page 18 SAFETY / LISTING LABEL - MODEL: EDVI25 MODEL NO. EDVI25 MANUFACTURED AT: Lynwood, CA FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL ALTITUDE 0-4500 FT/PI (0-1370M) MIN. GAS SUPPLY PRESS (“WC) PRESS MIN. D’ALIMENTATION (“ CE) 4.5” MANIFOLD PRESSURE (“WC) PRESSION CE TUBULURE (“CE)
  • Page 19 NOTE: THIS PAGE LEFT BLANK INTENTIONALLY. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
  • Page 20 Consult your local distributor for fi replace code information. Printed in U.S.A. © Lennox Hearth Products 2003 P/N 775,156M REV. G 3/2005 1110 West Taft Avenue • Orange, CA 92865...

This manual is also suitable for:

Elite edvi30Elite edvi35

Table of Contents