Atomic Digital Clock with Weather Forecast
The Atomic Digital Clock with Weather Forecast offers radio-controlled time, pressure history,
weather forecast, and indoor and outdoor temperature on one easy to read display.
WWVB
Reception
Forecast icon
Barometric
Pressure
History
FEATURES:
x
Four digit time display (3 inches high)
x
Atomic time and date with manual set option
x
Automatically updates for Daylight Saving Time (on/off option)
x
Choose from 5 languages (English, German, French, Dutch, Spanish).
x
Choose from 4 Time Zones (Eastern, Central, Mountain, Pacific).
x
12-hour or 24-hour selectable time
x
18-hour pressure history graph.
x
Forecast icons: sunny, partly cloudy, cloudy, rainy and stormy.
x
Daily Alarm
x
Perpetual calendar.
x
Indoor temperature (°F or °C)
x
Outdoor temperature (°F or °C)
x
Can read up to 3 outdoor transmitters
x
Wall hanging or free standing
x
Low battery indicator for receiver and transmitter
x
100 foot wireless transmission range (open air)
SET UP:
x
Remove the screws and the battery cover from the back of the transmitter with a small
screwdriver. (see install batteries in transmitter).
x
Set the transmitter to Channel 1.
x
NOTE: if you have additional transmitters set them to channel 2 and channel 3 respectively.
x
Insert fresh alkaline batteries into the transmitter, observing the correct polarity (see marking
inside battery compartment). Keep the transmitter 5-10 feet from the atomic clock.
x
Select Fahrenheit or Celsius for the transmitter display.
x
Insert batteries into the atomic clock, observing the correct polarity (see install batteries
into the atomic clock). Once the batteries are in place, all segments of the LCD will light up
briefly. The time will be displayed, as 12:00 and the outdoor temperature area will flash,
searching for the temperature transmitter(s).
x
After the batteries are inserted in the clock, press the TX button on the back of the
transmitter to send a signal to the clock.
x
Within 3 minutes the outdoor temperature should be displayed on the atomic clock. If
temperature does not show after 3 minutes, remove the batteries from both units for 60
seconds and start again from the beginning.
Manual
Introduction
Snooze icon
Date
Indoor
Temperature
1
2
Time
Alarm icon
Outdoor Temperature

Advertisement

loading

Summary of Contents for La Crosse Technology 512A-811

  • Page 1 512A-811 and 512B-811 Atomic Digital Clock with Weather Forecast Manual Introduction The Atomic Digital Clock with Weather Forecast offers radio-controlled time, pressure history, weather forecast, and indoor and outdoor temperature on one easy to read display. WWVB Snooze icon Reception...
  • Page 2: Wwvb Radio Controlled Time

    INSTALL BATTERIES IN THE TRANSMITTER: Remove the screws and the battery cover from the back of the transmitter with a small screwdriver. Select the channel to transmit the outdoor temperature. NOTE: if using more than one transmitter, set each transmitter to a different channel to be displayed on the atomic clock.
  • Page 3: Function Buttons

    Once the outdoor temperature is displayed on the atomic clock, the WWVB tower icon in the atomic clock display will start flashing in the top center of the LCD. This indicates that the atomic clock has detected a radio signal and is trying to receive it. When the time code is received, the WWVB tower becomes permanently lit and the time will be displayed.
  • Page 4 MINUTES: The Minutes will flash. Press and release the PLUS button to set the Minutes. Press the SET button once to continue. 12/24-HOUR TIME: 12hr or 24hr will flash. Press and release the PLUS button to select 12- hour or 24-hour time mode. Press the SET button once to continue. WEATHER FORECAST ICON: The forecast icon will flash.
  • Page 5: Positioning The Atomic Clock

    18-HOUR BAROMETRIC PRESSURE HISTORY GRAPH: The bar chart indicates the air pressure history trend over the last 18 hours in 5 steps, 0h, -3h, - 6h, -9h, & -18h. The columns represent the “hPa” at specific times. The “0” in the middle of this scale is equal to the current pressure and each change (0, -3, -6, -9, -18) represents how high or low in “hPa“...
  • Page 6: Low Battery

    La Crosse Technology, Ltd or La Crosse Technology, Ltd’s authorized service center. La Crosse Technology, Ltd will repair or replace this product, at our option and at no charge as stipulated herein, with new or reconditioned parts or products if found to be defective during the limited warranty period specified above.
  • Page 7 LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT. THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION. THIS PRODUCT IS NOT A TOY.

This manual is also suitable for:

512b-811