When installing:
• Ensure that the cables are attached to the cable guides firmly.
• When you route the cables, ensure that they are not subject to any tension. Tension could cause the
cables to be damaged by the cable guides, or a wire to be broken.
Step
Screw (quantity)
2
M2.5 × 6 mm, wafer-head, nylon-coated (4)
1170 DC-in connector and base cover assembly
For access, remove these FRUs in order:
•
"1010 Battery pack" on page 56
•
"1020 Bottom slot cover" on page 57
•
"1040 Hard disk drive or solid-state drive" on page 59
Color
Torque
Silver
0.392 Nm
(4 kgfcm)
.
Chapter 9
Removing or replacing a FRU
77