Chicago Electric 95136 Set Up And Operating Instructions Manual page 20

Inverter air plasma cutter
Table of Contents

Advertisement

Be CertAIn to shut off the Plasma Cutter, and disconnect it from power and air before
adjusting, cleaning, or repairing the unit. A technician should discharge all capacitors before
performing any internal procedures.
Cut gOes OnlY PArtIAllY thrOugh the WOrKPIeCe
turn up the current adjustment knob and
try again.
PrOBlem
COrreCted
You may wish to take note
of the setting required for
this metal thickness.
disconnect the torch Cables.
disassemble the torch assembly and
inspect all internal components, as ex-
plained on page 11.
tOrCh In gOOd
COndItIOn
try cutting at a slower pace, the arc may
not have enough time to cut through the
workpiece.
If the steps above do not solve the problem or if the repairs involved are too
Page 20
For technical questions, please call 1-800-444-3353.
trOuBleshOOtIng
ImPOrtAnt!
material being cut is too thick. maximum
thickness for steel is 1/2".
WIthIn thICKness
rAnge
PrOBlem PersIsts At
the Air pressure may be too low.
Check the Air Pressure setting on the
regulator's gauge.
AIr Pressure
COrreCt
complex, contact a qualified technician.
(COntInued)
You may wish to cut the
object along one side and
then cut along the other.
If this is not practical, use
a more powerful Cutter.
mAxImum settIng
a. verify that the compres-
b. the regulator on the
replace any damaged or missing compo-
nents and reassemble carefully, following
the directions on pages 9-11.
mAterIAl
tOO thICK
AIr Pressure
tOO lOW
sor is delivering at least
3.5 CFm @ 80 PsI to the
tool.
unit must be set to at
least 60 PsI.
dAmAged
COmPOnents FOund