Emergency Depressurization
If it is necessary to quickly depressurize the Compressor, turn the Power Switch OFF.
Then, pull on the ring on the Safety Valve to quickly release stored air pressure.
Automatic Shut off System
Figure I: Reset Button
Item 67847
Reset
Button
For technical questions, please call 1-800-444-3353.
1. If the Compressor automatically shuts off
before reaching its normal cutoff pressure:
a. Shut off all tools.
b. Wait until the Compressor cools down
(about 10 minutes);
c. If the unit does not start up again on its own,
press the Reset Button to start the compressor;
d. Resume operation.
2. Possible causes of repeated automatic
shut off of the compressor are:
a. Using an extension cord that is too long or narrow;
b. An air leak or open hose causing the compressor
to cycle too often and build up heat.
3. Correct any issues before further use to
avoid damage to the compressor.