Kompernass KH 5518 Instructions For Use Manual

Body fat-muscle mass and water analysis scales
Hide thumbs Also See for KH 5518:

Advertisement

KOMPERNASS GMBH
BURGSTRASSE 
D BOCHUM
www.kompernass.com
KH 5518/19
V2
UK
23-04-2007

Advertisement

Table of Contents
loading

Summary of Contents for Kompernass KH 5518

  • Page 1 KOMPERNASS GMBH BURGSTRASSE  D BOCHUM — www.kompernass.com KH 5518/19 23-04-2007...
  • Page 2: Instructions For Use

    KH 5518 Body fat, muscle mass and water analysis scales Instructions for use KH 5519...
  • Page 4 KH 5518 KH 5519...
  • Page 5: Table Of Contents

    Index 1. Safety instructions ......................... 4 2. Usage ............................5 3. Technical data ........................5 4. Scope of delivery ........................6 5. Components and operating elements ................... 6 5.1. Display remote control unit ......................6 5.2. Scales ...............................6 6. Preparing the scales for use ....................7 6.1.
  • Page 6: Safety Instructions

    ô Note: Warning! For the sake of simplicity, the body fat, muscle Do not place the scales and display remote mass and water analysis scales will be called control unit in the immediate vicinity of heat “scales” throughout these instructions for use. sources such as ovens, heaters and other simi- lar devices.
  • Page 7: Usage

    ô No liability will be taken and no guarantee Note: will be made for damages … No liability will be assumed and no warranty Ú resulting from opening the casings of granted for damages resulting from use of the scales and/or display remote control unit scales and/or display remote control unit for Ú...
  • Page 8: Scope Of Delivery

    Ú Measuring units adjustable: kg/lb, cm/inches 5. Components and Ú Battery status indicator Ú Overload indicator operating elements Ú Error indicator Ú Automatic shutoff of scales: aft er  seconds Ú Automatic shutoff of display remote con- 5.1. Display remote control unit trol unit: aft er ...
  • Page 9: Preparing The Scales For Use

    6.3. Inserting batteries in the 6. Preparing the scales for use display remote control unit Push the display remote control unit out 6.1. Unpacking the components of its holder on the back of the scales. Be careful not to drop the display remote Carefully remove the scales from the control unit.
  • Page 10: Prior To Initial Use

    Th e display remote control can be assembled 8. Prior to initial use on a wall above the scales with or without a wall holder. Th is is an alternative should the scales only be used exclusively at one location. For the assembly of the wall holder / display Before using the scales for the fi rst time, you remote control use either the double-sided ad-...
  • Page 11: Using The Scales

    Now the symbol for woman or the sym- Switch between the symbols by briefl y bol for man will appear on the display pressing the up and down buttons. Select screen. You can switch between the two the symbol corresponding to the catego- symbols by pressing the up and down ry which most accurately fi ts your eve- buttons.
  • Page 12: Measuring Body Weight, Body Fat, Muscle Mass And Body Water Percentages As Well As Caloric Requirement

    Lightly touch the top of the scales with ess is complete when the H stops blink- your foot. Th e on/off indicator on the scales ing. Th e weight displayed is your current should be illuminated in red. Aft er a few body weight.
  • Page 13 Otherwise the measurements can not be com- Lightly touch the top of the scales with pared. Diff ering measurement values could your foot. Th e on/off indicator on the be related to diff ering conditions for measure- scales should be illuminated in red. Af- ment and not to actual changes.
  • Page 14 Th e body weight appears in the low- Th e following displays are possible: er part of the display screen. Th e body Ú weight display can fl uctuate while meas- Under fat urements are being taken. Th erefore you Ú...
  • Page 15: Comparison Of Current And Previous Measurements

    ô Note: Press the i button once. Th e previous measurement result will blink on the dis- If you would like to track the development of play screen for comparison with the cur- your body fat, muscle mass and body water rent result.
  • Page 16: Using The Guest Mode (Gues)

    9.5. Using the guest mode (GUES) Select the memory location of your own personal data by pressing the up or down button. Press the i button when the memo- If … ry location number corresponding to your Ú personal data is displayed on the screen. all ten memory locations for personal data are already full Your personal data will appear on the dis-...
  • Page 17: Maintaining The Scales

    10.2. Replacing the batteries of Warning! the display remote control unit Do not place a load of more than  kilo- grams on the scales! Otherwise the scales If this symbol appears on the display screen: could be damaged beyond repair! Th e batteries of the display remote control unit Stand on the scales.
  • Page 18: The Display Remote Control Unit Can Not Be Turned On

    11.2. The display remote control 11.4. Error messages appear unit can not be turned on on the display screen If you can not turn on the display remote con- 11.4.1. “0-Ld” trol unit by press the on/off button: If this error message is displayed, then the Check to make sure that the batteries have weight on the scales exceeds ...
  • Page 19: Measurement Results Seem Unrealistic

    11.4.3. “––––” If you have carried out the measure- ments correctly: Th is error message indicates that the display re- mote control unit can not establish a connection Make sure that the stored personal data is to the scales. Possible causes for this could be: correct.
  • Page 20: Other Malfunctions

    11.6. Other malfunctions 13. Storing the scales Please refer to one of our service partners in your area if … If you are planning not to use the scales for a Ú the malfunctions described in sections .. long period of time: to ..
  • Page 21: Disposing Of The Scales

    Dispose of the packaging materials in an environmentally responsible manner. 15. Warranty & Customer Service Th e warranty conditions and service address can be found on the enclosed warranty sheet. 16. Importer KOMPERNASS GMBH BURGSTRASSE  D- BOCHUM www.kompernass.com...

Table of Contents