KUDSO1VM
Electrical: 120-volt, 60 Hz, AS-only, 15 or
20 amp electrical supply. Use copper wire only. A
time-delay fuse or circuit breaker and separate
circuit is recommended.
Water: A hot water line with 20-120 psi
(138-862 kPa) water pressure. Water temperature
must be minimum 120°F (49°0) at dishwasher.
Use 3/8" O.D. copper tubing with compression
fitting or flexible stainless steel braided fill line
(1/2" minimum plastic tubing is optional but not
recommended). Usea 90° elbow with 3/8" N.RT.
external pipe threads on one end to connect to
water inlet valve. Do not solder within 6" (15.2 cm)
from water inlet valve.
Drain: Usethe new drain hose supplied with your
dishwasher. If this is not suitable, use a new drain
hose with a maximum length of 12 feet (3.7 m)
that meets all current AHAM/IAPMO test
standards, is resistant to heat and detergent, and
fits the drain connector of the dishwasher. Must
have a high drain loop 20 inches (50.8 cm) above
the subfioor or floor. Connect drain hose to waste
tee or disposer inlet above drain trap in house
plumbing and 20 inches (50.8 cm) minimum
above the floor. An air gap must be used if the
drain hose is connected to house plumbing lower
than 20 inches (50.8 cm) above subfioor or floor.
Use 1/2" minimum I.D. drain line fittings.
Corner installation: Allow 2" (5,1 cm)
minimum betweencorner wall and dishwasher
opening.
Grommet is required for electrical cable or power
supply cord hole cut in a metal cabinet.
Do not install dishwasher over carpeted floor.
Unit accepts custom door panels.
CUSTOM FRONT PANEL DIMENSIONS
OVERALL DIMENSIONS
*For models using a 3/4"
(1 .gcm) custom wood front
panel, this dimension is
24-3/4" (62.9 cm).
-_---23-7/8"
(60.6 cm)_
3/4" (1.9 sin) insulation -
may be compressed
(not used on all models)
top vent
,,,_24-1/2"
(62.2 cm)* _,medel
/
_-
21" (53.3 cm) -_
CABINET OPENING DIMENSIONS
3/4" (1.g cm) insulation -
may he compressed
(not used on aH models)
_-_24-7/8"
(63.2 sin)
24-1/2" (62.2 sin)*
21" (53.3 sin)
front vent
model
33-7/8"
(86 cm) min.
with wheels
removed
__.4"
(61 urn)**
All sudaces must he free
from intrusions
2-3/4"
3-1/4"
(7 urn)
(8.3 urn)
Water line should enter through the
left side of opening in shaded areas.
Minimum 1/2" (12,7 ram} hole.
(5.1 urn}
(25.4
*Measured from the lowest point on the underside of conntedop.
34" (86.4 urn) min.*
(8.3era)
(7 cm}
Drain hose and power supply line should enter through the
right side of opening hi shaded areas.
Drain hose size: 1-1/2" (3.8 cm)
Power supply line hoJe-dffect wired: 3/4" (1 .gcm)
Powersupply line hole-withplug: 1-1/2" (3.8 uln)
May he reduced to 33-7/8" (86 cm) by removing wheels from dishwasher.
**Minimum,
measured from narrowest point of opening.
***May
he increased to 6-5/8" (16.6 urn} if height uf opening is 34-1/2" (87.6 urn} at its lowest point•
A custom trent panel
must weigh no mere
than 16 poundsand
mast he made to these
dimensions.
3/4"
(19.1 mm)
Front View
Front Vented Models
t
"25-29/32
(65.8 cm)
,ron_tPt
1/8 (3•2 ram)
(3.2ram)
Side
View
I___
23-3/8
__:_
3/4--_
(59.4 cm)
(1.9 cm)
Because Whirlpool Corporation policy includes a continuous commitment to improve our
Dimensions are for planning purposes only. For complete details, see Installation
Ref. 8564554
products, we reserve the right to change materials and specifications without notice.
Instructions packed with product. Specifications subject to change without notice.
10-04-04