Download Print this page

Crosley CAE5M13 Installation Instructions

Opp5k window mounting

Advertisement

Quick Links

|nstailation
instruct"
READ BEFORE iNSTALLiNG UNiT
OPP5K Window
Mounting
Your air conditioner is designed to install in standard
double hung windows with opening widths of 23 to 36
inches (584 mm to 914 mm) (FIG, 1)
Lower sash must open sufficiently to allow- a clear vertical
opening of 14-1/2 inches (368 ram). Side louvers and the
rear of the AC must have clear air space to allow
enough airflow through the condensel; for heat removal.
The rear of the unit must be outdoors, not inside a
building or garage.
NOTE:
SAVE CARTON and these ]INSTALLATION
INSTRUCTIONS
fin future reference. The carton is the
best way to store unit during winter, or when not in use.
Some assembly
is required,
Please read these instructions
carefully.
Mounting
Hardware
3/4"screws
lock flame
sash lock
Qty.
7
When handling
unit, be careful to avoid cuts
from sharp metal edges and aluminum
fins on
front and rear coils.
Before installing
unit, the top rail must be
assembled
on the unit.
Top Rail Hardware
Qty.
3/8" Screw-
4
Top Rail
1
TOOL
NEEDED:
__
T°'_'
aiit
*
Phillips Screwdriver
_z
A, Remove the air
conditioner from the
Packa
carton and place on a
flat surface,
[Zig. A
B. Remove top rail from
the bottom of the
packaging
material
as
shown in Fig. A
C. Align the hole in the
top rail with those in
the top of the unit as
shown in Fig. B
D, Secure the top rail to
the unit with the 3/8"
Screws as shown in
Fig. C
Fig._
TOOLS
NEEDED:
,
Phillips Screw Driver
*
Drill (If pilot holes are needed)
NOTE:
FOR SAFETY
REASONS,
ALL
FOUR (4) SCREWS
MUST BE SECURELY
FASTENED.
1
P/N 66129901121

Advertisement

loading

Summary of Contents for Crosley CAE5M13

  • Page 1 |nstailation instruct" READ BEFORE iNSTALLiNG UNiT OPP5K Window Mounting Your air conditioner is designed to install in standard double hung windows with opening widths of 23 to 36 inches (584 mm to 914 mm) (FIG, 1) When handling unit, be careful to avoid cuts from sharp metal edges and aluminum fins on Lower sash must open sufficiently to allow- a clear vertical...
  • Page 2 How to Install NOTE: Top Rail and Sliding Panels at each side are offset to provide the proper pitch to the rear of (5/16"). This is necessary for proper condensed water utilization and drainage. If you are not using the Side Panels for any reason, this pitch to the rear must be maintained! Place unit on floor, a bench or a table.
  • Page 3 Placethe framelock belweenthe frame Cut foamsealand insertin the space extensionsand the window sill asshown betweenthe upper andlower sashes (Fig.8).Drive 3/4" (19mm) locking (FIG.13). screwsthrough the framelock andinto the sill (FIG. 9 ).NOTE: To preventwindow sill from splitting,drill 1/8" (3 ram) pilot holesbefore driving screws.

This manual is also suitable for: