Installation
instructions
For Heavy
Duty {FAS Mode|s)
and
Median
{FAM
Mode|s)
Air Conditioners
Please read ALL instructions before installing.Two
people are
recmnmended
to install this product.If a new electrical outlet
is required,have
the outlet installed by a qualified electrician
before installing
unit. See#5 in Preliminary
Instructions
following.
Preliminary
instructions
Do the following belbre starting to install unit.See illustrations
below.
Check
dimensions
of your unit to determine
model type:
Heavy du_
(FAS)
Median
(FAM)
Unit Height:
18.5/8"
17.5/8"
Unit Width:
26 1/2"
23 1/2"
Min. Window Opening:
19"
18 1/,,
Min. Window Width:
31"
26 i/2"
Max. Window Width:
43"
40 i/_,,
1. Check window opening size - the mounting parts furnished
with this air conditioner are made to install in a wooden
sill double-hung
window.The
standard parts are i\_r
window dimensions
listed above.Open
sash to a minimum
of 19"(483mm).
(FIG. 1)
2.
Check condition
of window - all wood parts of window
must be in good shape and able to firmly hold the needed
scre_ s.][f not, make repairs be_\_re installing
unit.
FIG. 1
1/2" MIN
4.
T
19" MIN
1
STORM
WINDOW
FRAME
OR
OTHER OBSTRUCTION
SIDE
RETAFNER
J
.
Check your storm windows
- if your storm window
frame does not allow the clearance required, correct by
adding a piece of wood as shown in FIG.2, or by removing
storm window while room air conditioner is being installed.
(continued)
FIG.
2
_ASH
t
i
19" MIN
1/2" MIN
i 1/2" MIN
I
_
ENTIRE ST;OL,
FASTEN
STORM WINDOW
FRAME OR
WITH TWO NAILS OR
OTHER OBSTRUCTION
SCREWS.
P/N
66121625

Advertisement

loading

Summary of Contents for Crosley CAE15ESR1

  • Page 1 Installation instructions For Heavy Duty {FAS Mode|s) Median {FAM Mode|s) Air Conditioners Please read ALL instructions before installing.Two people are recmnmended to install this product.If a new electrical outlet is required,have the outlet installed by a qualified electrician before installing unit.
  • Page 2 CHECK FOR ANYTHING THAT COULD BLOCK Too|s Required AIRFLOW - check area outside of window for things such as shrubs, trees, or awnings. Inside, be sure a large flat blade screwdriver furniture, &apes, or blinds will not stop proper air flow. tape measure adjustable wrench...
  • Page 3 Window Mounti install Top Angle Remove Chassis and Side Bracket 1. Pull dewn fiont panel mad remove tilter. (See FIG. 1). Attach foam gasket to top angle above holes as 2. Lift fiont upwards and place to one side. shown in FIG. 6. FIG.
  • Page 4 |nstall Support 3. Insert top and bottom legs of window filler panel frame Bracket into channel in the to angle and bottom rail. Do both sides. Hold each support bracket flush against outside of sill, 4. Insert washer head locking screws (2) into holes in and tight to bottom of cabinet as shown below.
  • Page 5 install Chassis into Extend Window Filler Cabinet and |nstall Panels Front to Unit 1, Carefully raise window to expose filler panel locking 1. Lift air conditioner and carefully slide into cabinet screws. Loosen screws so filler panels slide easily. leaving 6" protruding. 2, _DO not push on controls OR finned coils, 3.
  • Page 6: Installation

    Thru-The-Wall Installation NOTE: Consult local building codes prior to installation, Carefully measure and cut an opening with the following or a qualified carpenter. dimensions depending on your model. See FIGS. land 2. WIDTH "X" - inside model width plus twice the thickness Select Wall Location...
  • Page 7 NOTE: If wall thickness is 8-1/2" or more, add aluminum flashing over bottom of flame opening to assure no water FIG.2 can enter area between inner and outer wall. 1"LONG WOOD SCREW Refer to Step 4 of Window Mounting for assembly of support brackets.A wooden strip nailed to the outside ALUMINUM FLASHING...
  • Page 8: Masonry Construction

    OPTIONAL:Caulking a udinstallation o f trimoninterior wallmay bedone. Youcanbuywood fromyourlocal l umber orhardware s upply. Ontheoutside, caulk openings around top and sides of cabinet, andallsides o f wood sleeve t otheopening. NOTE: See Step 7,Item3of Window Mounting Instructions forbottom railseal location. Masonry Construction 1.