Download Print this page
GE DSKS433EB0WW Installation Instructions
GE DSKS433EB0WW Installation Instructions

GE DSKS433EB0WW Installation Instructions

Advertisement

Quick Links

iNSTALLATiON
FO
YOUR N
NOTE TO INSTALLER
! STR
DRY
(USA only)
Be sure to leave these
installation
instructions
with the Consumer.
NOTE TO CONSUMER
Keep these installation instructions
with your
Use and Care Book for future reference.
Before you begin...Read
these instructions
completely and carefully
IMPORTANT:
OBSERVE
ALL GOVERNING
CODES
AND ORDINANCES
UNPLUG
DRYER
CORDSET
BEFORE
MAKING
ANY ADJUSTMENTS
MODELS
DSKS433
AND DSKS333
MUST BE INSTALLED
WITH CONTROL
PANEL AT BOTTOM
IN ORDER TO OPERATE
ADEQUATELY.
STACKING
KITS FOR DRYERS
(comeswith
individual
installation
instructions)
[]
Over washer
- Use Wall Mount Kit WMK-35 or
- Stack Rack DSDR24 or
- Stack Rack DSR-24
[]
For alcove and closet depth and width requirements
see
specific kit instructions
[] All stacking kits are available from your local sales outlet.
TOOLS
YOU WILL NEED
[]
Slip joint pliers
[]
Fiat blade screwdrivers
[]
Phiiips screwdrivers
MATERIALS
YOU WILL NEED
4"DIA.METAL DUCT
(RECOMMENDED)
[]
SAFETY G LASSES
>
[]
[]
4"DUCT
4"DIA.METAL
CLAMPS ( 2)
ELBOW
OR
4"SPRING
CLAMPS ( 2) []
[]
DUCT TAPE
[]
EXHAUSTHOOD
[]
GLOVES
[]
3/4"STRAIN RELIEF
ULRECOGNIZED
[]
_/,.
DRYER POWER
CORD KIT
(NOTPROVIDED
WITHDRYER. FOR
240VMODEL O NLY).
UL RATED120/240V, 3 0A
WITH 3 OR4 PRONGS,
IDENTIFY THEPLUGTYPE
AS PERTHEHOUSE
RECEPTACLE B EFORE
PURCHASING LINECORD.
UNPACKING
AND PREPARING
FOR INSTALLATION
[]
Prepare the area and exhaust for instal-
lation of new dryer.
[]
Check and ensure the existing external
exhaust is clean and meets attached
installation specifications.
[]
Remove the literature and accessories
bag from the dryer drum. Place the liter-
ature in a convenient place.
[]
Using foam pads from dryer carton,
turn dryer upside down as shown.
[]
install knobs, For location, refer to "Use and
Care" Book.
c] Dryer is now ready to be mounted above washer using acces-
sory kit.
[]
Remove the foam shipping pads from under dryer.
[]
Move the dryer to the desired location.
[]
Follow the steps in the following pages to connect the dryer to
the external exhaust and power supply.
DETERMINE
ELECTRICAL
REQUIREMENTS
FOR
YOUR DRYER MODEL
This dryer must be connected to an individual branch circuit of
proper voltage and frequency
as specified on Rating Plate (locat-
ed inside dryer door) with no other appliances
or fixtures
attached.
EXCEPTION:
A 120V receptacle is located on the back on the dryer and is
available only for use with a washer that is affixed to the dryer
with a WDF-85 kit. it may not be used for any other appliance or
any conditions other than stated above, (208 & 240V models
only).
Branch circuit must be protected by the required time-delay fuses or
circuit breakers. 208V or 240V installation - 30 amps. 120V installation
15 or 20 amps.
The electrical installation must conform to the national and local
codes,
208V
AND
240V
MODELS
ARE
NOT APPROVED
FOR 1
i
120 V INSTALLATION.
PAGE 1

Advertisement

loading

Summary of Contents for GE DSKS433EB0WW

  • Page 1 ! STR iNSTALLATiON (USA only) YOUR N NOTE TO INSTALLER Be sure to leave these installation instructions with the Consumer. NOTE TO CONSUMER Keep these installation instructions with your Use and Care Book for future reference. Before you begin...Read these instructions completely and carefully IMPORTANT: OBSERVE...
  • Page 2 ELECTRICAL CONNECTION DETAILS OBSERVE ALL GOVERNING CODES AND ORDINANCES GROUNDING iNSTRUCTiONS • The operating voltage (Volts), Amperage (Amps) and Frequency This appliance must be grounded. In the event of malfunction (Hz) of this dryer are indicated on the Rating PLate located to the breakdown, grounding will reduce the risk of electric shock by providing...
  • Page 3 EXHAUSTING THE DRYER TO THE OUTSIDE IS STRONGLY RECOMMENDED TO PREVENT LARGE AMOUNTS OF MOISTURE LiNT FROM BEING BLOWN iNTO THE ROOM. CAUTION: FOR PERSONAL SAFETY . At least once a year inspect and clean ductwork. . Do not terminate exhaust in a chimney, any gas vent, under an enclosed •...
  • Page 4 WALL CAPS TURNS OTHER THAN 90 ° ,, Atl e xhaust systems must beterminated insuch a manner as toprevent o One turn of 45 ° or less be ignored. back d rafts f rom outside aswetl astoprevent entry ofbirds o rother * Two such turns should...

This manual is also suitable for:

Dsks433eb0whDsks433eb1wwDsks433eb1whDsks333ec0wwDsks333ec0whDskp333ec0ww ... Show all