Cardinal CS Series Operation Manual

Cs series digital counting scale
Hide thumbs Also See for CS Series:

Advertisement

This Document is Hosted by: www.oldwillknottscales.com
Digital Counting Scale
CS Series
Operation Manual
Cardinal Scale Manufacturing Co.
8526-M256-01 Rev B
PO BOX 151 WEBB CITY, MO 64870
07/10
PH (417) 673-4631 - FAX (417) 673-5001
www.detectoscale.com
8526-M256-O1 Rev B • CS Series
Technical Support: Ph: 866-254-8261 • techsupport@cardet.com
1

Advertisement

Table of Contents
loading

Summary of Contents for Cardinal CS Series

  • Page 1 Digital Counting Scale CS Series Operation Manual Cardinal Scale Manufacturing Co. 8526-M256-01 Rev B PO BOX 151 WEBB CITY, MO 64870 07/10 PH (417) 673-4631 - FAX (417) 673-5001 www.detectoscale.com 8526-M256-O1 Rev B • CS Series Technical Support: Ph: 866-254-8261 • techsupport@cardet.com...
  • Page 2 8526-M256-O1 Rev B • CS Series...
  • Page 3: Table Of Contents

    Nor can they assume responsibility for any damage to property or injury to persons occasioned from the procedures. Persons engaging the procedures do so entirely at their own risk. 8526-M256-O1 Rev B • CS Series...
  • Page 4: Specifications

    INTRODUCTION Thank you for purchasing our Detecto CS Series Digital Counting Scale. Your scale is equipped with a rechargeable battery pack that is able to provide 100 hours continuous operation (with backlight on) or 200 hours continuous operation (with backlight off).
  • Page 5: Installation

    INSTALLATION Unpacking Before beginning installation of your CS Series Digital Counting Scale, make certain the instrument has been received in good condition. Carefully remove the instrument from the shipping carton and inspect it for any evidence of damage (such as exterior dents or scratches) that may have taken place during shipment.
  • Page 6: Precautions

    PRECAUTIONS Most scales are designed for an office type environment. The CS Series Digital Counting Scale is no exception to that rule. The following should be used as a guideline for the proper environment to operate your scale: • The environment should be free of excessive dust and moisture.
  • Page 7: Key Functions

    ± 4% of scale capacity. Calibration and Operational Setup Mode: Pressing the ZERO key and then pressing the setup parameter number on the numeric keypad while displayed will enter that setup mode. 8526-M256-O1 Rev B • CS Series...
  • Page 8 CE key and re-enter the correct data. • Count Mode: Pressing the CE key while in the Count mode will finish the counting operation, update the quantity and weight accumulators and return the scale to the Weight mode. 8526-M256-O1 Rev B • CS Series...
  • Page 9: Annunciators

    “Minimum Unit Weight”. The scale can still count the quantity even though the unit weight is too small; however, this may affect the counting accuracy. 8526-M256-O1 Rev B • CS Series...
  • Page 10 UNITS key may be used to select kilogram as the weighing units. The lb annunciator is turned on to show that the weight displayed is in pounds. The UNITS key may be used to select pounds as the weighing units. 8526-M256-O1 Rev B • CS Series...
  • Page 11: Operation

    COUNT displays), press the ZERO key. 2. The WEIGHT display will show (six dashes) for a few seconds and then return to . The ZERO and Stable annunciators will illuminate, indicating a center-of-zero, stable gross weight condition. 8526-M256-O1 Rev B • CS Series...
  • Page 12: Counting

    SAMPLE annunciator will stay on to show the out-of-tolerance count. 6. Add the pieces to be counted and read the count. 7. Press the CE key to complete the counting operation and return to the Weight mode. 8526-M256-O1 Rev B • CS Series...
  • Page 13: Tare Weight Entry

    5. Proceed with the counting or weighing operation. To Clear the Tare To return to a zero tare, simply remove all material from the scale platform and press the TARE key, which will reset the tare weight to zero. 8526-M256-O1 Rev B • CS Series...
  • Page 14: Accumulator

    With the scale in the Weight mode, press the M+ key to display the content of the accumulators. The values of the accumulator will be displayed for 3 seconds, then return to the Weight mode display. Clearing the Accumulator Press the MC key. The accumulator will be reset to zero. 8526-M256-O1 Rev B • CS Series...
  • Page 15: Quantity/Weight Hi Preset Limits

    5. The scale will return to the Weight mode. Clear the Quantity and Weight Preset Hi Limits To clear the Quantity and/or Weight Preset Hi Limit, simply enter a “0” for the limit value. 8526-M256-O1 Rev B • CS Series...
  • Page 16: Operational Setup

    10 minutes. – No Backlight The will be no backlight (always OFF). NOTE! The backlight mode is stored in memory and will restored when the scale is switched off and back on again. 8526-M256-O1 Rev B • CS Series...
  • Page 17 – Automatic Average Unit Weight Function If counting data increases over 10% compared with the previous sampling value, and the increase is less than 100% of previous sampling value, the automatic unit weight calibration will be proceed again. 8526-M256-O1 Rev B • CS Series...
  • Page 18 Pre-Tare data, the Pre-Tare data can not be less or equal to ±3 bits external value, and so on. When the weight is over 1/3 full capacity and return to 0, this function will be started. 8526-M256-O1 Rev B • CS Series...
  • Page 19 = Press the M+ key. After screen displays accumulation data, the scale will not return to the Weight mode until the CE key is pressed. = Press the M+ key. The screen does not display accumulation data. The beeper will “beep” once. 8526-M256-O1 Rev B • CS Series...
  • Page 20 = If the weighing quantity exceeds quantity setting (or weight exceeds weight setting), and it doesn’t matter if the weight is stable, the beeper will sound automatically. 8526-M256-O1 Rev B • CS Series...
  • Page 21 4. The scale will return to the Weight mode ( will be displayed for WEIGHT and will be displayed for the PIECE WEIGHT and COUNT displays). 5. The scale is ready for normal use. 8526-M256-O1 Rev B • CS Series...
  • Page 22: Calibration

    15. The scale will return to the Weight mode ( will be displayed for WEIGHT and will be displayed for the PIECE WEIGHT and COUNT displays). 16. The scale is ready for normal use. 8526-M256-O1 Rev B • CS Series...
  • Page 23: Gravity Adjustment

    PIECE WEIGHT and COUNT displays). 17. The scale is ready for normal use. NOTE! By default, the USA gravity adjustment value will be used. Consult the factory Tech Support for the gravity adjustment value for your location. 8526-M256-O1 Rev B • CS Series...
  • Page 24: Rs232 And Serial Printer Setup

    Otherwise, using the numeric keys, enter the desired setting for the Baud Rate and press the MC key to save it. Available values are 00 through 05. 600 bits/second 1200 bits/second 2400 bits/second 4800 bits/second 9600 bits/second 19200 bits/second 8526-M256-O1 Rev B • CS Series...
  • Page 25 Fixed format 1 (details on the next page) Fixed format 2 (details on the next page) Reserved Same as screen display (general format) Same as screen display (simple format) Gross weight (general format) Net weight (general format) Tare (general format) 8526-M256-O1 Rev B • CS Series...
  • Page 26 RS232 AND SERIAL PRINTER SETUP, CONT. Example: Illustration for fixed format is described as follows: 8526-M256-O1 Rev B • CS Series...
  • Page 27 (fixed format 2), the continuous transmission mode may only work with short distances. • If is set as (Reserved), continuous transmission mode is not available. • If is set as through , continuous transmission mode is available. 8526-M256-O1 Rev B • CS Series...
  • Page 28 Transmission Output Condition and press the MC key to save it. Available values are 00 or 01. Output all No output under OL or unstable condition • The setting will only be effective when is set as “continuous transmission mode”. 8526-M256-O1 Rev B • CS Series...
  • Page 29 Condition for Automatic Transmission Condition and press the MC key to save it. Available values are 00 through 02. External value “0d” External value “0d” External value “0d” • Only if setting is set as “automatic transmission mode” will setting be effective 8526-M256-O1 Rev B • CS Series...
  • Page 30: Error And Status Displays

    Check if battery is installed and installed correctly. Is battery discharged? Recharge or replace battery. Incorrect weight displayed Insure that the scale platform isn't touching an adjacent object. Have proper operation procedures been followed? 8526-M256-O1 Rev B • CS Series...
  • Page 31: Appendix 1 - Rs-232 Full Duplex Format

    APPENDIX 1 – RS-232 FULL DUPLEX FORMAT 8526-M256-O1 Rev B • CS Series...
  • Page 32 APPENDIX 1 – RS-232 FULL DUPLEX FORMAT, CONT. 8526-M256-O1 Rev B • CS Series...
  • Page 33: Appendix 2 - Fixed Format Rs-232 Transmission Line Illustration

    APPENDIX 2 – FIXED FORMAT RS-232 TRANSMISSION LINE ILLUSTRATION 8526-M256-O1 Rev B • CS Series...
  • Page 34: Appendix 3 - Ascii Code Table

    APPENDIX 3 – ASCII CODE TABLE 8526-M256-O1 Rev B • CS Series...
  • Page 35: Appendix 4 - 7-Segment Display Characters

    APPENDIX 4 – 7-SEGMENT DISPLAY CHARACTERS 8526-M256-O1 Rev B • CS Series...
  • Page 36 8526-M256-O1 Rev B • CS Series...