Owner's Use and Care Guide
•Welcome
• Important Safety Information
• Installation Instructions
• Features
• Operating Instructions
• Care and Maintenance
• Troubleshooting
• Warranty
,
DESHUMIDIFICATEUR PORTATIF
Guide d'utilisation et soins de Proprietaire
...............................11 - 20
• Bienvenue
• Consignes de Securite lmportante
• Consignes d'installation
• Caracteristiques
• Consignes de Fonctionnement
• Soins et Entretien
• Depannage
• Garantie
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE: If the Dehumidifier changes
ownership, be sure this manual accompanies the
unit.
CONSERVER CES INSTRUCTIONS POUR CONSULTATION ULTERIEURE: En cas de revente du
deshumidificateur, ce manuel doit etre inclus avec l'appareil.
Danby Products Limited, Guelph, Ontario, Canada NIH 6Z9
Ohio, U.S.A.45840
Danby Products Inc.
Findlay,
v.
1.11.10
JF

Advertisement

Table of Contents
loading

Summary of Contents for Danby Premiere DDR30A1GP

  • Page 1 CONSERVER CES INSTRUCTIONS POUR CONSULTATION ULTERIEURE: En cas de revente du deshumidificateur, ce manuel doit etre inclus avec l'appareil. Danby Products Limited, Guelph, Ontario, Canada NIH 6Z9 Ohio, U.S.A.45840 Danby Products Inc. Findlay,...
  • Page 3 WELCOME Thank you for choosing a Danby appliance to provide you and your family with all of the "Home Comfort" requirements of your home, cottage, or office. This Owner's Use and Care Guide will provide you with valuable information necessary for the proper care and maintenance of your new appliance. If properly maintained, your Danby appliance will give you many years of trouble free operation.
  • Page 4: Electrical Requirements

    Contact your dealer, service agent, or the manufacturer about any problems or conditions you do not fully understand. For Danby Customer Service calll-800-26-Dallb.r (1-800-263-2629) ELECTRICAL To reduce the risk of fire, elecrric shock, or personal injury, all wiring and grounding REQUIREMENTS must conform with the latest edition of Local and National Electricarcodes.
  • Page 5: Installation Instructions

    INSTALLATION INSTRUCTIONS LOCATION • Select a suitable location, making sure you have easy access to an electrical outlet (avoid the use of extension cords). If it is absolutely necessary to use an extension cord, use an approved "air conditioner" heavy duty extension cord ONLY (available at most local hardware stores). •...
  • Page 6: Caster Installation

    CASTER INSTALLATION Caster installation is recommended to avoid damage to floors. !.Remove the casters from the bucket of the dehumidifier. 2. Position the dehumidifier on its side. 3. Locate the arrow on the bottom of the dehumidifier and insert the caster according to the arrow direction. 4.
  • Page 7 OPERATING INSTRUCTIONS (cont'd)
  • Page 8: Start Operation

    START OPERATION 1) Place the product in an upright rating label. position on a flat, stable, ana neat- 3) Make sure the water tank is correctly resistant surface. Make sure there is located. switchinon the machine nothin2 flammable or heat sensitive After ,oocm inches).Onerating...
  • Page 9 OPERATING INSTRUCTIONS (cont'd) OPERATING INSTRUCTIONS (cont'd) DEFROST When the machine is operated at low temperatures (less than l8°C) (64.4°F), the surface of the evaporator may accwnulate a layer of frost which would reduce the efficiency of the machine. When this hap ens the machine will go into penodic defrost mode.
  • Page 11 OPERATING INSTRUCTIONS (cont'd) INSTALLING PVC When using the continuous drain function, the PVC hose must be placed horizontally HOSE DRAIN below the drainage hole. Avoid uneven ground and folding the hose. NOTE:Should you damage or rmsplace the pvc drain hose, a standard garden hose can be used. CONTINUOUS 0 ·...
  • Page 12 the unit (Fig. D). hose- - ,_ \\ 8) Place the bucket in its original location (Fig. E). IFig.Dl ' - -- J ' - Drain cover ;;!II hose 1Fig. Drain.. 0-Bucket...
  • Page 13 OPERATING INSTRUCTIONS (cont'd) CAUTIONS 1) DO NOT pull on the power cord to avoid breakage, potential danger, or injury. 2) DO NOT use insect/oil/paint spray around the machine; these products might cause damage to plastic parts or start a fue. 3) DO NOT place the unit on uneven ground to avoid shaking, noise, and water leakage.
  • Page 15: Care And Maintenance

    Occasionally, you may encounter some problems that are of a minor nature and a service call may not be necessary. Use this troubleshooting guide to identify possible problems you may be experiencing. If the unit continues to operate improperly, call your local Danby Service Depot or 1-800-26..Danb.r (1-800-263-2629) PROBLEM POSSffiLE CAUSE •...
  • Page 16 Tniere. LIMITED APPLIANCE WARRANTY llli&CJIIIilypu!Ld isWIII!'Btadtl !Mlilai:U'a(a tlefacla il1T111181ial and mn.wlip. pMildlllllllle urit uaad IJ'dallhencnnal betill& Qrld lin i1terde<l 11\e manliac1ure1. Danbv lllla'tiiiiiTIICy Mllaliurijtllhe pe D ID fltum uri!M S rdjdd by o.nl1j PnxiJdslin!lad {Cirtd)« Plc4JIS$ h:. (USA)(lleraeltar « 'UtJVf) <IIIJtiiJtrciDaJtlf, end 1e lEAliSOFWAIIIWITY...