F. Glass Assembly
WARNING
Handle glass doors with care.
• Inspect the gasket to ensure it is
undamaged.
• Inspect the glass for cracks, chips or
scratches.
• Any scratch in glass, requires replacement.
• Do NOT strike, slam or scratch glass.
• Do NOT operate appliance with glass door removed,
cracked, broken or scratched.
• Replace glass door assembly as a complete appliance.
Removing Glass Assembly
Pull the four glass assembly latches out of the groove on
the glass frame. Remove glass door from the appliance
(see Figure 12.5).
Replacing Glass Assembly
Replace the glass door on the appliance. Pull out and
latch the four glass assembly latches into the groove on
the glass frame.
L ATCHE S
(BOTH BOT TO M
AND TOP )
GLASS
ASSEMB LY
Figure 12.5 Glass Assembly
G. Grilles and Trim
Install optional marble and brass trim surround kits as de-
sired. Marble, brass, brick, tile, or other non-combustible
materials can be used to cover up the gap between the
sheet rock and the appliance.
Do not obstruct or modify the air inlet/outlet grilles or hood.
When overlapping on both sides, leave enough space so
that the bottom grille can be lowered and the trim door
removed.
H. Air Shutter Setting
This appliance has an adjustable air shutter (which con-
trols the primary air) factory set for the minimum vertical
vent run (see Figure 12.6). If your installation has more
than the minimum required vertical vent length, adjust-
ment of the air shutter may be necessary to obtain optimal
fl ame appearance. This should be adjusted by a quali-
fi ed installer at the time of installation.
By sliding the air shutter to the right, you will be closing
the air shutter. To adjust loosen the wing nut. Care should
be taken when adjusting the air shutter so as not to cause
the appliance to soot. If sooting occurs the air shutter will
need to be opened by sliding the air shutter to the left.
When fi nished, tighten wing nut.
S H U TTE R A D JU S TM E N T
Figure 12.6
Shutter Settings
Models
NG
LP
SL-550TR-E
3/16 in.
3/16 in.
SL-750TR-E
3/16 in.
3/16 in.
SL-950TR-E
3/8 in.
Full Open