Install Termination Cap - Heat & Glo Heat&Glo RUTHERFORD-36 Owner's Manual

Installation and operation
Table of Contents

Advertisement

D. Install Termination Cap
Install the chimney sections up through the chase enclo-
sure.
Install termination caps following instructions provided
with them.
WARNING! Risk of Fire! The minimum overlap of cap
to pipe (as shown in the following illustrations) MUST
be met or chimney may separate from cap. Separation
allows sparks, heat and embers to escape.
NOTICE: The termination cap can be painted with a rust-
resistant paint to protect against the effects of corrosion
on those parts exposed to the weather.
TR11, TR11-TV Round Termination Cap
Slip
storm collar
around chimney pipe
before termination
cap pipe is snapped
into the chimney
pipe.
Caulk gaps between
storm collar & pipe,
and storm collar
& chase top.
Collar
2 in. (51 mm)
Minimum Height
Chase Top
Termination cap pipe and chimney section must be snapped
together to maintain an overlap of 1-1/2 in. (38 mm).
Figure 9.4
Installing a TR11 & TR11-TV Round Termination Cap
34
Termination
Cap
Do NOT
block air holes
6 in. (153 mm)
Storm
Minimum top of
Collar
chase to top of
chimney pipe
Chimney
Pipe
Chase
Heat & Glo • RUTHERFORD-36 • 4059-341 Rev D • 03/09
TR11T Round Telescoping Termination Cap
Assemble
Termination
storm collar
around extended
termination cap
pipe
once cap is
installed.
Caulk gaps between
storm collar & pipe,
and storm collar
& chase top.
Collar
2 in. (51 mm)
Minimum Height
Chase Top
Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)
Figure 9.5
Installing a TR11T Round Telescoping Termination Cap
ST1175 Square Termination Cap
Termination Cap
Collar
2 in. (51 mm)
Minimum Height
Chase Top
Chimney
Pipe
Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)
Figure 9.6
Installing an ST1175 Square Termination Cap
Cap
Do NOT
block air
holes
Storm
Collar
3 clip brackets.
Slip over chase collar
and attach with screws
provided.
14 1/2 in. (368 mm)
Maximum
Chase
Chimney
Pipe
Place waterproof
caulk or sealer under
each flange of the
termination cap and
on top of each screw
to help prevent leaks.
Flange
4 3/4 in. (121 mm)
Maximum
top of chase to
top of
chimney section
Chase

Advertisement

Table of Contents
loading

Table of Contents