Chauvet Hurricane 1100 User Manual

Chauvet hurricane 1100
Hide thumbs Also See for Hurricane 1100:

Advertisement

Quick Links

Hurricane™ 1100
F-1100

USER MANUAL

th
3000 N 29
Ct, Hollywood, FL 33020 U.S.A.
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
Snapshot
OK on Dimmer
Outdoor OK
Sound Activated
DMX512
Master/Slave
115V/230V Switch
Replaceable Fuse
User Serviceable
Duty Cycle

Advertisement

Table of Contents
loading

Summary of Contents for Chauvet Hurricane 1100

  • Page 1: User Manual

    Snapshot Hurricane™ 1100 OK on Dimmer F-1100 Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL 3000 N 29 Ct, Hollywood, FL 33020 U.S.A. (800) 762-1084 – (954) 929-1115 FAX (954) 929-5560 www.chauvetlighting.com...
  • Page 2: Table Of Contents

    ABLE OF ONTENTS 1. Before You Begin ..........................2 What is included ............................2 Unpacking Instructions ..........................2 AC Power ..............................3 Safety Instructions ............................ 3 2. Introduction ............................4 Features ..............................4 Product Dimensions ..........................4 Product Overview............................5 Fuse Replacement ............................
  • Page 3: Ac Power

    There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact CHAUVET at: 954-929-1115. Hurricane™ 1100 User Manual 3/26/2009 3:17 PM...
  • Page 4: Introduction

    2. I NTRODUCTION Features Output: 8,000cfm 1.3L tank capacity Uses 1L every 21min (continuous use at full output) 5 minute heat up Manual fog button Low fluid indicator and auto shut down Wired remote included Water-based fogger Product Dimensions Hurricane™ 1100 User Manual 3/26/2009 3:17 PM...
  • Page 5: Product Overview

    Product Overview Hanging bracket Fluid container Safety cable eye bolt Tilt Adjustment knob Heater Nozzle Manual Fog Low Fluid button indicator Fluid level indicator Manual Controller Wireless Controller Power input (hardwired) Fuse holder Hurricane™ 1100 User Manual 3/26/2009 3:17 PM...
  • Page 6: Fuse Replacement

    Disconnect the power cord before replacing a fuse and always replace with the same type fuse. Fuse Replacement With a flat head screwdriver wedge the fuse holder out of its housing. Remove the damaged The fuse is located fuse from its holder and replace with exact inside this compartment.
  • Page 7: Operating Instructions

    5. O PERATING NSTRUCTIONS Operation This mode will allow you to control the fogger manually, set the fog machine to run continuously, or to set the fog machine to run off bursts with adjustable interval and duration settings. Manual Remote Operation (FC-M) (Standard) Plug in the fog machine to power.
  • Page 8: Wireless Controller (Fc-W)

    Wireless Controller (FC-W) (Optional) This mode will allow you to control the fogger using the optional wireless controller. This consists of the transmitter and the receiver. You may control up to 4 independent fog machines, or many more if you run them simultaneously.
  • Page 9: Contact Us

    Possible bad part. Contact Chauvet or a Chauvet Dealer/distributor for further instruction. If you still have a problem after trying the above solutions, please contact CHAUVET Technical Support at the location listed below. Contact Us Wor l d Wi de...
  • Page 10: Appendix

    Package must be clearly labeled with a Return Merchandise Authorization Number (RMA #). Products returned without a RMA # will be refused. Call CHAUVET and request a RMA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return.
  • Page 11: Blow-Out Diagram

    Blow-out Diagram. Description Part Number Master PCB 120V P170-F1MSPCB Master PCB 220V 220VP170-F1MSPCB Heater 700W 550° Celsius 120V P120-HT7 Heater 700W 550° Celsius 220V 220VP120-HT7 Pump 120V P200-F1PUMP Pump 220V 220VP200-F1PUMP Fluid container 1.3 liters P70-F1FLC Fluid sensor P170-F1FLOS Thermal switch 115° Celsius P170-THEF11 Bracket Knob P111-F1BKNOB...
  • Page 12: Connections Drawing

    Connections Drawing In the event that any part(s) may need to be replaced/repaired, you may use the below diagram to assist in this operation. Warning: All repairs should only be performed by Authorized Service Personnel. Hurricane™ 1100 User Manual 3/26/2009 3:17 PM...
  • Page 13: Technical Specifications

    Technical Specifications WEIGHT & DIMENSIONS Length ..........................9.7 in (247 mm) Width ..........................9.6 in (243 mm) Height ..........................8.7 in (220 mm) Weight ..........................8.3 lbs (3.8 kg) POWER AC Power ..................... 120V 60Hz AC or 230V 50Hz Fuse (115V) ........................... 8A 250V Power Consumption ..................

Table of Contents