APPLICATION
Model OFSD-211 is approved for use in walls, partitions, and floors
with fire resistance ratings less than 3 hours. OFSD-211 is an 'out of
the wall' high performance combination fire smoke damper with 3V
style blades. Removal of wall grille allows access to actuator and
other components. This model's operational ratings of 2000 fpm (10.2
m/s) and pressures to 4 in. wg (1 kPa). Model OFSD-211 shall be
installed vertically (with blades running horizontal) or horizontally and
is rated for airflow and leakage in either direction.
Ratings
UL555 Fire Resistance Rating:
Fire Rating:
Dynamic Closure Rating: Actual ratings are size dependent
Max. Velocity:
Max. Pressure:
UL555S Leakage Rating:
Leakage Class:
Operational Rating:
Max. Velocity:
Max. Pressure:
Max. Temperature:
STANdARd CONSTRuCTION
Frame:
Blades:
Seals:
Linkage:
Closure device:
Axles:
Bearings:
Sleeve:
SIze LImITATIONS:
minimum Size:
maximum Size:
OPTIONAL FeATuReS:
• POC retaining Angles
• RRL/OCI (open closed indication switches)
• 165ºF (74ºC), 212ºF (100ºC), 250ºF (121ºC), 350ºF (177ºC) RRL's
available
• TOR (remote override allows damper to perform smoke
management functions during fire emergency.)
• Electric actuators
• Momentary switch
• Security bars
• Sealed transition and sleeves
Out Of Wall Combination FIRe SmOKe dAmPeRS
1
hours in walls
1
2
2000 fpm (10.2 m/s)
4 in. wg (1 kPa) - differential
pressure
I
Actual ratings are size dependent
2000 fpm (10.2m/s)
4 in. wg (1 kPa)
350ºF (177ºC)- depending upon the
actuator
5 in. x 1 in. (127mm x 25mm)
galvanized steel hat channel with
reinforced corners. A low profile
head and sill are used on sizes less
than 17 in. (432mm) high.
16 ga. (1.5mm) galvanized steel,
reinforced with 3 longitudinal
structurally designed vee's.
Extruded silicone rubber blade seals.
Flexible stainless steel jamb seals.
Concealed in jamb
UL listed 165°F (74ºC) RRL
½ in. (13mm) dia. plated steel
Bronze sleeve type
Galvanized; wrapped with thermal
blanket
12 in. W x 12 in. H
(305mm x 305mm)
Single section: 36 in. W x 36 in. H
(914mm x 914mm)
UL555 1
Model OFSD-211 meets the requirements for fire
dampers, smoke dampers and combination fire
smoke dampers established by:
National Fire Protection Association
NFPA Standards 80, 90A, 92A, 92B, 101 & 105
IBC International Building Codes
ICBO uniform Building Codes
CSFm California State Fire marshal
Fire Damper Listing (#3225-0981:103)
Leakage (Smoke) Damper Listing (#3230-0981:104)
New York City (MEA listing #260-91-M)
"uL CLASSIFIed (see complete marking on
product)"
"uL CLASSIFIed to Canadian safety standards
(see complete marking on product)"
Standard 555 & 555S (Listing #R13317)
Greenheck Fan Corporation certifies that the
model OFSD-211 shown herein is licensed to bear
the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
with AMCA Publication 511 and comply with the
requirements of the AMCA Certified Ratings Pro-
R
grams. The AMCA Certified Ratings Seal applies to
air performance ratings only.
* W & H dimensions furnished approximately
(Add blanket thickness (
sleeved damper dimension)
Oversize wall opening as follows:
Nominal damper size plus
Installation instructions available at www.greenheck.com
model OFSd-211
Steel 3V Blades
UL 555S Leakage Class I
Hour Fire Resistance Rating
1
2
Horizontal or Vertical Mount
1
in. (6mm) undersize.
4
1
in.[3mm]) and sleeve thickness for overall
8
3
in.(9.5mm) (see Page 6)
8

Advertisement

loading

Summary of Contents for Greenheck OFSD-211

  • Page 1 APPLICATION Model OFSD-211 is approved for use in walls, partitions, and floors with fire resistance ratings less than 3 hours. OFSD-211 is an ‘out of the wall’ high performance combination fire smoke damper with 3V style blades. Removal of wall grille allows access to actuator and other components.
  • Page 2: Pressure Drop Data

    Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. Figure 5.3 Figure 5.2 Figure 5.5 OFSd-211 (1.201 kg/m 4 (W) (H) 3.14 4 (W) (H) 3.14...
  • Page 3 1.16 4000 0.64 Greenheck Fan Corporation certifies that the model OFSD-211 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Pro- grams.
  • Page 4 0.63 4000 0.42 Greenheck Fan Corporation certifies that the model OFSD-211 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Pro- grams.
  • Page 5 2.17 4000 1.86 Greenheck Fan Corporation certifies that the model OFSD-211 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Pro- grams.
  • Page 6: Application Data

    UL 555S rated for leakage and airflow in either direction through the damper. Each damper shall be supplied with a 165°F (74°C) RRL. The basis of design is Greenheck Model OFSD-211. OFSd-211 Factory supplied thermal...