Download Print this page
Greenheck Fire Smoke Dampers FSDGB-211 Specification Sheet
Greenheck Fire Smoke Dampers FSDGB-211 Specification Sheet

Greenheck Fire Smoke Dampers FSDGB-211 Specification Sheet

Greenheck fan corp. combination fire smoke dampers specification sheet

Advertisement

Quick Links

Application
Model FSDGB-211 is a combination fire smoke damper with 3V style
blades. The FSDGB-211 has been qualified to Standard
GB 15931-1995 for operation and closure in emergency fire smoke
situations. Model FSDGB-211 may be installed vertically (with
blades running horizontal) or horizontally and is rated for airflow and
leakage in either direction.
Ratings
Standard GB 15931-1995
Velocity:
Pressure:
Standard Construction
Frame:
Blades:
Seals:
Linkage:
Axles:
Bearings:
Fusible Link:
Size Limitations
Minimum Size:
Maximum Size:
Single Section:
Multiple Section:
Optional Features
• Stainless steel bearings
• OCI (Open closed indication switches)
• Retaining Angles
• Transitions (C, O, R)
• Sealed transitions and sleeves
• Sleeve with integral flange on both sides
Combination
10 m/s (2000 fpm)
1kPa (4 in. wg)
127mm x 25.4 mm (5 in. x 1 in.)
1.24mm galvanized steel hat
channel with reinforced corners. A
low profile head and sill are used on
sizes less than 432mm (17 in.) high
to maximize free area and
performance.
1.24mm (16 ga.) galvanized steel,
reinforced with 3 longitudinal
structurally designed vee's.
Extruded silicone rubber blade
seals. Flexible stainless steel jamb
seals.
Concealed in jamb.
12.7 mm (
in.) dia. plated steel.
1
2
Bronze sleeve type.
280° C
204mm W x 152mm H
(8 in. W x 6 in. H)
813mm W x 914mm H
(32 in. W x 36 in. H)
1626mm W x 914mm H
(64 in. W x 36 in. H)
FIRE SMOKE DAMPERS
Model FSDGB-211
Qualified to Standard GB 15931-1995
Greenheck Kunshan Co. Ltd. and Greenheck Fan
Corporation certifies that the model FSDGB-211
shown herein is licensed to bear the AMCA Seal. The
ratings shown are based on tests and procedures
performed in accordance with AMCA Publication
511 and comply with the requirements of the AMCA
R
Certified Ratings Programs. The AMCA Certified
Ratings Seal applies to air performance ratings only.
* W & H dimensions furnished approximately 6mm ( 1 /4 in.)
undersize.
(Add sleeve thickness for overall sleeved damper dimension)
Right hand drive is shown. Left hand drive is available upon request.
Steel 3V Blades

Advertisement

loading

Summary of Contents for Greenheck Fire Smoke Dampers FSDGB-211

  • Page 1 Application Model FSDGB-211 is a combination fire smoke damper with 3V style blades. The FSDGB-211 has been qualified to Standard GB 15931-1995 for operation and closure in emergency fire smoke situations. Model FSDGB-211 may be installed vertically (with blades running horizontal) or horizontally and is rated for airflow and leakage in either direction. Ratings Standard GB 15931-1995 Velocity: 10 m/s (2000 fpm) Pressure: 1kPa (4 in. wg) Standard Construction Frame: 127mm x 25.4 mm (5 in. x 1 in.) 1.24mm galvanized steel hat channel with reinforced corners. A low profile head and sill are used on sizes less than 432mm (17 in.) high to maximize free area and performance. Blades: 1.24mm (16 ga.) galvanized steel, reinforced with 3 longitudinal structurally designed vee’s. Seals: Extruded silicone rubber blade seals. Flexible stainless steel jamb seals. Linkage: Concealed in jamb. Axles: 12.7 mm ( Bearings: Bronze sleeve type. Fusible Link: 280° C Size Limitations Minimum Size: 204mm W x 152mm H...
  • Page 2: Pressure Drop Data

    Pressure Drop Data This pressure drop testing was conducted in accordance with AMCA Standard 500-D using the three configurations shown. All data has been corrected to represent standard air at a density of 1.201 kg/m 3 . Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. FSDGB-211 4 (W) (H) 3.14...
  • Page 3 AMCA 5.2 Pressure Drop 305mm x 305mm 610mm x 610mm Velocity Pressure Velocity (m/s) Drop (Pa) (m/s) 10.3 12.6 12.9 15.5 15.4 17.8 18.1 20.8 20.8 Figure 5.3 Figure 5.2 Figure 5.5 914mm x 914mm Pressure Velocity Pressure Drop (Pa) (m/s) Drop (Pa) 10.2 12.7 15.3 17.7 20.3 Greenheck Kunshan Co. Ltd. and Greenheck Fan Corporation certifies that the model FSDGB-211 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures...
  • Page 4 AMCA 5.3 Pressure Drop Figure 5.3 Figure 5.2 Figure 5.5 305mm x 305mm 610mm x 610mm Velocity Pressure Velocity (m/s) Drop (Pa) (m/s) 10.3 10.3 12.9 12.8 15.4 15.5 17.7 17.9 20.8 20.8 914mm x 914mm Pressure Velocity Pressure Drop (Pa) (m/s) Drop (Pa) 10.1 12.8 15.3 17.7 20.3 Greenheck Kunshan Co. Ltd. and Greenheck Fan Corporation certifies that the model FSDGB-211 shown herein is licensed to bear the AMCA Seal. The...
  • Page 5 AMCA 5.5 Pressure Drop 1000 305mm x 305mm 610mm x 610mm Velocity Pressure Velocity (m/s) Drop (Pa) (m/s) 10.2 10.3 12.7 12.8 15.4 15.3 17.9 17.7 20.6 20.8 VELOCITY VS. PRESSURE DROP FACE VELOCITY- METERS/SECOND AMCA 5.5 914mm x 914mm Pressure Velocity Pressure Drop (Pa) (m/s) Drop (Pa) 10.2 12.9 15.5 18.1...
  • Page 6: Specifications

    Specifications Combination Fire Smoke Dampers meeting the following specifications shall be furnished and installed where shown on plans and/or as described in schedules. Dampers shall meet the requirements of NFPA 80, 90A, 92A, 92B, 101 & 105 and further shall be tested , rated and labeled in accordance with GB 15931 standard. Each damper /actuator combination shall have a UL555S elevated temperature rating of 280°C minimum and shall be operational and dynamic rated to operate at maximum design air flow at its installed location. Each damper shall be supplied with an appropriate actuator installed by the damper manufacturer at the time of damper fabrication. Damper actuator shall be (specifier select one of the following) electric type for 120 (24 or 230) volt operation or pneumatic type for 25 psi minimum (30 psi maximum) operation. Damper blades shall be 1.24mm galvanized steel 3V type with three longitudinal grooves for reinforcement. Damper frame shall be galvanized steel formed into a structural hat channel shape with reinforced corners. Bearings shall be sintered bronze sleeve type rotating in extruded holes in the damper frame. Blade edge seals shall be silicone rubber designed to inflate and provide a tighter seal against leakage as pressure on either side of the damper increases. Jamb seals shall be stainless steel compression type. Blades shall be completely symmetrical relative to their axle pivot point, presenting identical resistance to airflow in either direction or pressure on either side of the damper. The Damper Manufacturer's submittal data shall certify all air performance pressure drop data is licensed in accordance with the AMCA Certified Ratings Program for Test Figures 5.2, 5.3, and 5.5. Damper air performance data shall be developed in accordance with the latest edition of AMCA Standard 500-D. Dampers shall be labeled with the AMCA Air Performance Seal. Damper must be rated for mounting vertically (with blades running horizontal) or horizontally and be UL 555S rated for leakage and airflow in either direction through the damper. Each damper shall be supplied with a 280°C fusible link. The basis of design is Greenheck Model FSDGB-211. GREENHECK Greenheck Kunshan Co Ltd. 17 Qunyi Minying District •...