& operating Manual The TL300 Top Loading Wood Stove EPA Certified by OMNI-Test Laboratories SaFeTY noTice PLeaSe read ThiS enTire ManuaL beFore You inSTaLL and uSe Your neW rooM heaTer. FaiLure To FoLLoW inSTrucTionS MaY reSuLT in ProPerTY daMage, bodiLY injurY, or even deaTh.
Please read this entire manual before you install and use your new heating appliance. Failure to follow instructions may result in property damage, bodily injury, or even death. Hearth & Home Technologies, Inc. 352 Mountain House Road Halifax, PA 17032 ~ U.S.A. Harman TL300...
The Harman TL300 offers a cooking grill that can be placed in the top of the stove while in operation. This allows you to grill your favorite meats all year long even when the weather is not suitable for outside grilling. If you haven't already purchased the cooking grill, you can do so from your Authorized Harman Dealer.
A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. The Harman TL300 meets the U.S. Environmental Protection Agency’s emission limits for wood heaters sold after July 1, 1990. Harman TL300...
Page 6
Specifications Top Load Door Top Load Opening Front Load Door Grate Top Load Door Handle Andirons Air Control Ash Door Front Load Door Latch Ash Door Latch Harman TL300...
Do not burn garbage or flammable fluids such as gasoline, naptha, or engine oil. The glass used in your TL300 is manufactured to exact standards to withstand the high heat of the fire, but like all glass, it must be treated with common sense and care. Never...
Fireplace installations must meet these same (HUD), CFR 3280, part 24. clearance requirements; specifically follow these guidelines When installing the TL300 in a mobile home, several re- for mantel and trim clearances. quirements must be met: For corner installations, the clearance distances from the 1.
Page 9
Corner Installation with Single and Double Wall Pipe 18" 27" 18" 27" (450 mm) (675 mm) (450 mm) (675 mm) 27" 27" (675 mm) (675 mm) 18" 18" (450 mm) (450 mm) *Check with your local building codes for clearance. Harman TL300...
When installed and operated according to this manual, the United States In the U.S., the national code is NFPA 211. TL300 will produce enough hot gases to keep the chimney While many localities adopt this standard, be sure to check warm so that adequate draft is maintained throughout the with local authorities before beginning your installation.
AN APPROVED U.S. WALL PASS-THROUGH WALL PASS-THROUGH The Chimney The TL300 must be installed into a chimney approved for Do not connect this unit to a chimney use with solid-fuel appliances. In the U.S., the TL300 must flue servicing another appliance.
Page 12
Other causes of poor ventilation or draft are icing, exhaust TL300. In addition to the requirements found in the previ- fans, a blocked outside air inlet, and room air starvation. If...
Page 13
Standard Ceiling Installation with Cathedral Ceiling Installation with Factory Built Chimney Factory Built Chimney Harman TL300...
Page 14
Minimum of three Sheet Airtight Metal Screws per Joint of insulated Chimney Connector Clean-out Mantel and Trim Protection Damper Closed and Sealed with Floor Protection* Non-Combus- tible Material. Combustible Floor * Floor Protection in Accordance with Solid Fuel Appliance Listing Harman TL300...
Page 15
Approved Thimbles insulated Clean-out Mantel & Trim Protection Damper Closed and Sealed with Noncombustible Material. Floor Protection* Combustible Floor * Floor Protecion in Accordance with Solid Fuel Appliance Listing ** Check with your local building codes for clearance. Harman TL300...
Page 16
Two important controls - the top load door handle and The Combustion Process the air control lever regulate the operation and output Combustion in the Harman TL300 is precisely con- of the stove. trolled and is divided into two parts.
At high settings, above the first notch on the air control, the blower may be set to your desired control level. Be sure the blower cord does not run under, over, or in front of the stove. Harman TL300...
Page 18
Do not throw water The TL300 was designed to allow access to the ash on the fire; this can cause stove damage and create an pan without the need for opening the main door. Before even more dangerous situation.
Maintenance Glass - Replacement Like all fine equipment, your TL300 requires some If the stove’s glass is cracked or broken, you must routine maintenance and inspection. Follow the guide- replace it before operating your stove. Remove pieces lines in this section to assure safe, efficient operation.
The Chimney System Gaskets are used at strategic positions when building Creosote the Harman TL300 for controlling the path that incom- When wood is burned slowly, it produces tar and other ing and outgoing air and gases take through the stove.
Check with your local building inspector to find out be hot enough to cause physical harm. requirements determining if outside air is needed when installing the TL300 in your area. Some signs to watch Cozy Screen- #3-40-06960 for that indicate a possible need for outside air: Poor...
TL300 Service Parts beginning Manufacturing date: aug. 2007 Wood Stove ending Manufacturing date: active 1-90-06900-1 (black), 1-90-06900-2 (charcoal), 1-90-06900-3 (goldenfi re), 1-90-06900-4 (Metallic blue), 1-90-06900-5 (honey glo), 1-90-06900-10 (Mojave red), 1-90-06900-12 (Forest green) Part number list on following page. 12/10...
Page 23
TL300 Service Parts beginning Manufacturing date: aug. 2007 ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
TL300 Service Parts beginning Manufacturing date: aug. 2007 ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
Page 25
TL300 Service Parts beginning Manufacturing date: aug. 2007 ending Manufacturing date: active #19 Firebox assembly 19.1 19.2 19.8 19.3 19.5 19.7 19.6 19.4 19.13 19.12 19.11 19.9 19.10 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
Page 26
This page intentionally left blank. Harman TL300...