Genie garage door opener user manual.

   
IMPORTANT INSTALLATION INSTRUCTIONS
WARNING:
1. READ AND FOLLOW ALL SAFETY, INSTALLATION
AND OPERATION INSTRUCTIONS.
questions or do not understand an instruction, call The
Genie Company or an authorized Genie
2. Install only on a properly balanced sectional garage door.
An improperly balanced door could cause severe injury.
Have a trained door system technician make repairs or
adjustments to cables, spring assemblies, and other
hardware before installing the opener.
3. Remove all ropes and remove or make inoperative all
locks connected to the garage door before installing opener.
4. Where possible, install the door opener 7 feet or more
above the floor. For products having an emergency
release, mount the emergency release 6 feet above the floor.
NOTE: Please follow ALL instructions in their NUMBERED sequence. Use wall control and safety sensors
provided with this unit. Do NOT substitute wall control or safety sensors.
1
OPENER ASSEMBLY
RAIL ASSEMBLY: Use a clean, flat surface.
NOTE: For 1-piece rail—skip to POWER HEAD &
RAIL ASSEMBLY.
WARNING
To reduce the risk of injury to persons or
damage to property - Use this opener only
with sectional doors.
CAUTION
Do NOT run until opener is fully assembled and
instructed to do so.
NOTE: Three (3) piece rail assemblies are for a 7
foot high sectional door.
Clear a workspace area to unpack and organize box
and contents for assembly.
1. There are 4 boxes inside the carton. Each box is
numbered 1 - 4. Note that some openers will
contain the same parts and be packaged with
fewer boxes. Carefully remove the three
internal boxes (Labeled #1, 2, and 3) and place
them on the floor for easy access (Fig. 1-1).
These boxes contain assembly parts and the
contents are organized by assembly tasks. For
quick reference inside the lid of each box there is
a label illustrating the components inside.
2. Remove the motor power head and place it on
the floor for later use. Remove box #4 and
place it on the floor for later use.
To reduce the risk of severe injury or death:
(If you have
®
Dealer.)
PN# 37026500123
5. Do NOT connect the opener to source of power
until instructed to do so.
6. Locate the Wall Control:
• Within sight of door,
• At minimum height of 5 feet so small children are not
able to reach it, and
• Away from all moving parts of the door.
7. Install the Entrapment WARNING Label next to the Wall
Control in a prominent location. Install the Emergency
Release Tag on or next to the emergency release.
8. After installing the opener, the door must reverse within
2 seconds when it contacts a 1-1/2 inch high object (or a
2 x 4 board laid flat) on the floor.
FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM
Rail Connectors
Bag 0
Rail Connector Bolts
Rail Connector Nuts
Bolts
Bag 1
Rail
Power head
Box Label Example
FIG. 1-1
Internal boxes.
02/26/2010 REV. 1
#4
Bag 2
Header Bracket
Header Bracket
Bolts
Lag Srews
Bag 3
5/16" Nuts
& Bolts
9
Next page -> <- Previous page

Comments to this Manuals

Symbols: 0

Latest comments:

  • Judy Walsh Apr 15, 2013 08:57:
    I have a 2024 Profession​al Line. I bought Genie Model #G3T-R remote. The instructio​ns for programmin​g are impossible to follow. Please send me a step by step instructio​n on what buttons to push when on both the garage door opener and the remote so that it will program. Thank you - or call me and we will do it together 210- 216 0077
  • Robert Sycks Nov 06, 2012 04:57:
    I was looking for help with my opener not a political statement.

    I have my last Genie.
×

Select the desired size and copy embed code

Copy your embed code and put on your site: