CHAPTER 2. ANSI EMULATION

CONTROL CODE AND ESCAPE SEQUENCE ACTIVITY LEVELS
GEK-00029B
ANSI control codes and escape sequences are assigned activity levels
depending on which print mode is currently active. The following
charts provide information on what to expect from the control codes
and escape sequences in each printing mode.
I -IGNORED
No noticeable effect on printing will occur.
V -VALID
These sequences do not affect the printing mode in
progress, but take effect when normal printing
resumes.
A –ACTIVE
This sequence takes effect immediately.
D –DATA
These control codes are used as data.
Notes
Note 1
When printer option 1 is active, either in ANSI (4800)
or ANSI (4410) emulation, <SO> and <SI> activate or
deactivate this printing mode. <SO> and <SI> are
VALID in bar codes and oversize print mode. They are
ACTIVE in expanded print mode. Please see Appendix
D, Description of Strapping options, ANSI (4800) or
ANSI (4410) tables on page 271 for details on options
which affect printer operation in ANSI emulation.
Note 2
VALID during enhanced oversize, ACTIVE during
normal oversize.
Note 3
Discarded while in the native mode.
Note 4
Causes an error symbol to print (XOX).