Wire Connections - York LX series Owner's Manual

Residential digital thermostat backlit display
Hide thumbs Also See for LX series:
Table of Contents

Advertisement

Installation Instructions

Wire Connections

Wire Connections
If the terminal designations on your old thermostat
YOUR NAME
I
Am
2:00
74
MO
C
OO
L S
ET
78
Outdoor
H
EAT ET
S
85
68
do not match those on the new thermostat, refer
to the chart below or the wiring diagrams
that follow.
Wire from the
old thermostat
terminal marked
G or F
Y1, Y or C
W1, W or H
Rh, R, M, Vr, A
C
O/B
2nd Stage Heat
W2
2nd Stage Cooling
Y2
W3
3rd Stage Heat
H, HUM
D, DEHUM
Dehumidity
Ck1
Dry Contact Switch
Dry Contact Switch
CKGND
* O/B is used if your system is a Heat Pump.
Install on the
new thermostat
Function
connector marked
Fan
G
Cooling
Y1
W1/O/B
Heating
Power
R
Common
C
W1/O/B*
Rev. Valve
W2
Y2
W3
HUM
Humidity
DEHUM
DRY CONTACT
DRY CONTACT
Page 8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S1-tbsu32p7yS1-thsu21p1S1-thsu32p7S1-thsu32hp7