Troubleshooting - Generac Power Systems 9801-7 Owner's Manual

10,000 watt ac generator
Table of Contents

Advertisement

TROUBLESHOOTING

Problem
Engine is running, but no
AC output is available.
Engine runs good at no-
load but "bogs" down"
when loads are connected.
Engine will not start; or
starts and runs rough.
Engine shuts down during
operation.
Engine lacks power.
Engine "hunts" or falters.
10000EXL Extended Life Generator
Cause
1.
One of the circuit breakers is open.
2.
Fault in generator.
3.
Poor connection or defective cord set.
4.
Connected device is bad.
1.
Short circuit in a connected load.
2.
Engine speed is too slow.
3.
Generator is overloaded.
4.
Shorted generator circuit.
1.
Ignition Switch set to "Stop".
2.
Fuel Valve is in the "Off" position.
3.
Dirty air cleaner.
4.
Out of gasoline.
5.
Stale gasoline.
6.
Spark plug wire not connected to
spark plug.
7.
Bad spark plug.
8.
Water in gasoline.
9.
Overchoking.
10. Excessively rich fuel mixture.
11. Intake valve stuck open or closed.
12. Engine has lost compression.
13. Failed battery.
1.
Out of gasoline.
2.
Low oil level.
1.
Load is too high.
2.
Dirty air filter.
1.
Choke is opened too soon.
2.
Carburetor is running too rich or too
lean.
Correction
1.
Reset circuit breaker.
2.
Contact Generac service facility.
3.
Check and repair.
4.
Connect another device that is in
good condition.
1.
Disconnect shorted electrical load.
2.
Contact Generac service facility.
3.
See "Don't Overload the Generator"
on page 12.
4.
Contact Generac service facility.
1.
Set switch to "On".
2.
Turn fuel valve to the "On" position.
3.
Clean or replace air cleaner.
4.
Fill fuel tank.
5.
Drain gas tank; fill with fresh fuel.
6.
Connect wire to spark plug.
7.
Replace spark plug.
8.
Drain gas tank; fill with fresh fuel.
9.
Open choke fully and crank engine.
10. Contact Briggs and Stratton service
facility.
11. Contact Briggs and Stratton service
facility.
12. Contact Briggs and Stratton service
facility.
13. Replace battery.
1.
Fill fuel tank.
2.
Fill crankcase to proper level.
1.
See "Don't Overload the Generator"
on page 12.
2.
Replace air filter.
1.
Move choke to halfway position until
engine runs smoothly.
2.
Contact Briggs and Stratton service
facility.
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

10000exl