GE JV536 Owner's Manual And Installation Instructions page 12

Vented range hoods
Table of Contents

Advertisement

8
REMOVE DUCT KNOCKOUT(S)
If recirculating, non-vented ductless (optional for
JV5 Series models only), see note below and skip to
Step 12 D and proceed. We do not recommend the
recirculated configuration for JV6 Series models.
Using a flat blade screwdriver, remove the appropriate
duct knockout(s) from the top or back of the hood.
" x 10" Rectangular
3
1
4
vertical discharge.
Remove top rectangular
duct knockout only.
NOTE: If the hood is to be installed in a recirculating,
non-vented ductless manner, order charcoal filters,
kit number WB02X10707 for 30
kit number WB02X10708 for 36
These kits can be ordered from your GE supplier.
Skip to Step 12 D and proceed.
9
FOR HORIZONTAL DISCHARGE
INSTALLATIONS ONLY:
Remove the plate (on models so equipped) in front
of the horizontal discharge knockout. Cut the ties,
lift plate out and discard plate. DO NOT REMOVE
the metal strip held in place with two screws.
Ties
Metal strip
Screw
Plate
Installation Instructions
7" Round vertical
discharge. Remove semi-
circular duct knockout and top
rectangular duct knockout.
" x 10" Rectangular
3
1
4
horizontal discharge. Remove
rear rectangular duct knockout only.
"
hood models or
"
hood models.
" X 10" RECTANGULAR
10
FOR 3
1
4
DUCTED DISCHARGE
INSTALLATIONS ONLY:
Attach exhaust adaptor/damper over knockout
opening with two exhaust adaptor screws. Make sure
damper pivot is nearest to top/back edge of hood.
Remove tape from damper flap.
Up to 1" side-to-
side adjustment
Pivot
NOTE: The exhaust adaptor/damper can be installed
up to 1 inch on either side of the hood center to
accommodate off-center ductwork. In extreme off-
center installations, one end of the duct connector may
need to be trimmed to clear the electrical cable clamp.
11
FOR 7" ROUND VERTICAL
DUCTED DISCHARGE
INSTALLATIONS ONLY:
Re-install the 7" round exhaust adaptor with its
screws, removed in Step 2 under the "Prepare the
Hood" section.
NOTE: The 7" round exhaust adaptor can be installed
up to 1 inch on either side of the hood center to
accommodate off-center ductwork. In extreme off-center
installations, one end of the duct connector may need
to be trimmed to clear the electrical cable clamp.
NOTE: The 7" round damper is not included with
this product. It can be purchased as a kit by calling
800.626.2002. Order kit number JXDA23.
12
Top/back edge
Exhaust adaptor/damper
(vertical discharge position
shown)
7" round
exhaust
adaptor
Tape

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jv565Jv635Jv566Jv636Jv665Jv666 ... Show all

Table of Contents