About The Controls On The Dehumidifier; Other Features - GE AHM30 Owner's Manual

Hide thumbs Also See for AHM30:
Table of Contents

Advertisement

Available languages

Available languages

About the controls on the dehumidifier.

Controls
Power Pad
Press to turn the dehumidifier on and off.
Continuous
Select for the dehumidifier to
operate continuously at its maximum
dehumidification settings until the bucket is
full. The Humidity Set Control Pads cannot
be used when Continuous is on.
Humidity Set Control Pads
The humidity level can be set within a range
of 35% RH (Relative Humidity) to 80% RH
(Relative Humidity) in 5% increments.
For drier air, press the
a lower percent value (%).
For damper air, press the
to a higher percent value (%).
When you first use the dehumidifier, set
the humidity control to 45% or 50%. Allow
at least 24 hours for the dehumidifier to
achieve the humidity level. If you still have
damper air than desired, set the humidity
level to a lower setting or select Continuous
for maximum dehumidification.

Other Features

BUCKET FULL Light
Glows when the bucket is ready to be emptied,
or when the bucket is removed or not replaced
in the proper position.
Auto Shut Off
The Water Level Control Switch shuts off the
dehumidifier when the bucket is full, or when
the bucket is removed or not replaced in the
proper position.
4
Power on
Continuous
Bucket full light
indicator light
operation on
indicates bucket
indicator light
needs to be
emptied
M
pad and set to
L
pad and set
High fan
Normal fan
indicator light
indicator light
Fan Speed Pads
Control the fan speed.
Press to select either High or Normal fan
speed.
Set the fan control to High for maximum
moisture removal. When the humidity
has been reduced and quiet operation is
preferred, set the fan control to Normal.
Display
Shows the set % humidity level while
setting, then shows the actual (+/– 5%
accuracy) room % humidity level.
Error Codes
E1 – Humidity sensor error – Unplug the
unit and plug it back in.
E2 – Temperature sensor error – Unplug
the unit and plug it back in.
P1 – Unit is defrosting – Allow the unit time
to automatically defrost. The error will
clear after the unit self defrosts.
P2 – Water bucket is full – Empty the water
bucket and replace. See the Removing
Collected Water section.
Auto Defrost
When frost builds up on the evaporator coils,
the compressor will cycle off and the fan will
continue to run until the frost disappears.
Power Outage
In the case of a power outage or interruption,
the unit will automatically re-start, in the settings
last used, after the power is restored.

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Ahw30Ahh40Ahm40Ahm65 series

Table of Contents