Remote Programming Routine - Clarion UNGO ProSecurity S100 Installation Manual

Hide thumbs Also See for UNGO ProSecurity S100:
Table of Contents

Advertisement

ative pulses instead of a single pulse. At the same time, the GREEN H2/A wire will supply two positive
pulses instead of a single pulse. This makes it possible to directly interface with double pulse vehicles
without any extra parts.
2-9 CHANNEL 3 VALIDITY/LATCHED/LATCHED RESET WITH IGNITION/30 SECOND TIMED/SECOND
UNLOCK OUTPUT: Channel 3 can be programmed for these output configurations. The unit is set to the
default validity output. To change the configuration, use the two-chirp setting to toggle to the different
configurations.

remote programming routine

The system comes with two remotes that have been taught to it. The system can store up to four differ-
ent remote codes in memory. Use the following learn routine to add remotes to the system or to change
button assignments if desired.
If the system was previously programmed using the Pro Security Programmer, the programming routine
may be locked. If the siren generates one long chirp when attempting to program the unit, the pro-
gramming routine is locked and must be unlocked using the Pro Security Programmer before proceed-
ing.
1.
Open a door. (The GREEN wire, H1/5, or the VIOLET, H1/7 must be connected.)
2.
Turn the ignition on. (The YELLOW wire, H1/9 must be connected.)
3.
Select the receiver channel: Press and release the Override switch the number of
times necessary to access the desired channel.
N N O O T T E E : : If adding a remote, a button must be taught to the unit in the Channel 1 or Channel 4 position
prior to programming other channels.
Press and hold the Override switch once more. The siren will chirp and the LED will blink the number
of times corresponding to the channel that is accessed.
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents