Aprilaire 8081 TT Installation Instructions

Support module

Advertisement

Quick Links

Installation Instructions

TAblE OF CONTENTS

Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Installation location recommendations . . . . . . . . . . . . . 2
Support module mounting . . . . . . . . . . . . . . . . . . . . . . . 2
Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
FEATURES
The 8081 TT/ 8082 TrH Support Modules are designed to work with the Model 8800 Universal Communicating Thermostat.
Up to four support modules per thermostat can be used to monitor temperature and/or humidity in various rooms or throughout
a larger area. The temperatures or humidity readings can also be averaged to create a controlling value for the thermostat.
MODEl 8081 TT OpTIONS
• 1 on board temperature sensor
• 1 on board and one remote temperature sensor*
• 1 remote temperature sensor*
• 2 remote temperature sensors*
* For remote temperature sensors use the Aprilaire Model 8051 Flush Mount Temperature Sensor, Model 8052 Duct/Outdoor
Temperature Sensor, or the Model 8053 Surface Mount Temperature Sensor.
READ AND SAVE THESE INSTRUCTIONS
8081 TT / 8082 TrH
Support Module
Dip switch configuration . . . . . . . . . . . . . . . . . . . . . . 5-6
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
MODEl 8082 TrH OpTIONS
• 1 on board humidity sensor and 1 on board
temperature sensor
• 1 on board humidity sensor and 1 remote
temperature sensor*
1

Advertisement

loading

Summary of Contents for Aprilaire 8081 TT

  • Page 1: Table Of Contents

    • 1 on board and one remote temperature sensor* • 1 on board humidity sensor and 1 remote • 1 remote temperature sensor* temperature sensor* • 2 remote temperature sensors* * For remote temperature sensors use the Aprilaire Model 8051 Flush Mount Temperature Sensor, Model 8052 Duct/Outdoor Temperature Sensor, or the Model 8053 Surface Mount Temperature Sensor.
  • Page 2: Installation Location Recommendations

    INSTAllATION RECOMMENDATIONS WIRING CONTROllING SENSOR SHOUlD bE MOUNTED: DO NOT MOUNT CONTROllING SENSOR: WIRING TERMINAlS • O n an interior wall, in a frequently occupied space. • B ehind doors, in corners or other dead air spaces. RC – 24vAC (RC terminal at the Model 8800 Thermostat) • A pproximately 5’ above the floor. • I n direct sunlight, near lighting fixtures, or other C – Common (C terminal at the Model 8800 Thermostat) appliances that give off heat. • A t least 18” from outside wall. RSA & RSb – Communication to the Model 8800 Thermostat • O n an outside or unconditioned area wall. T1 & T2 – Remote sensor terminals for Sensor 1 • I n the flow of a supply register, in stairwells, or near T3 &...
  • Page 3 WIRING DIp SWITCH CONFIGURATION (CONTINUED) The Support Module has 6 dip switches, as shown in the WIRING DIAGRAM diagram to the right, that must be configured. The 8800 ADDRESS ADDRESS thermostat must be powered down for 90 seconds for dip ADDRESS ADDRESS switch settings to take effect. MONITOR (S1) CONTROL (S1) 8800 8082 8081 MONITOR (S2) CONTROL (S2) SPARE SPARE T1/T2 (S1) ONBOARD SENSOR SUppORT MODUlE ADDRESS SElECTION – DIp SWITCH 1 & 2 each Support Module must have its own unique address.
  • Page 4: Dip Switch Configuration

    DIp SWITCH CONFIGURATION TROUblESHOOTING (CONTINUED) SENSOR 2 MODE – DIp SWITCH 4 THE 8800 THERMOSTAT DISplAy IS blANK 8081 • C heck circuit breaker and reset if necessary. • M ake sure power switch at heating & cooling system is on. This dip switch determines if sensor 2, which is the remote sensor on T3&T4, is a controlling (on) or monitoring (off) temperature. • M ake sure furnace door is closed securely. If the switch is set to off, sensor 2 will monitor the temperature. All monitoring values will cycle through the message center on the thermostat. THE 8800 THERMOSTAT DISplAyS A VERy HIGH TEMpERATURE If the switch is set to on, the 8800 thermostat will use sensor 2 as its controlling value which will also be displayed verify the appropriate setting of dip switch 6. If the dip switch is set to use the on board sensor, but a remote sensor at the 8800 thermostat. If multiple sensors are set to control, the values will be averaged and the average value will...
  • Page 5: Accessories

    • C an be painted or wall papered to match décor. • F or indoor installation only. MODEl 8052 OUTDOOR/DUCT MOUNT TEMpERATURE SENSOR • U se to monitor air temperature (return or supply duct, outdoor, freezers, wine cellar). • C an also be used to control floor temperature (requires clipping metal bracket). • U se to monitor water by affixing it to outside of water pipe and insulate. • F or indoor and outdoor use. MODEl 8053 SURFACE MOUNT TEMpERATURE SENSOR • U se on surfaces where surface mount design is best suited (brick, concrete). • F or indoor use only. P.O. Box 1467 • Madison, WI 53701-1467 • Phone: 800/334-6011 • Fax: 608/257-4357 www.aprilairepartners.com 61000793 4.11 Printed in U.S.A. B2205461A © 2011 Aprilaire – A division of Research Products Corporation...

This manual is also suitable for:

8082 trh