Page of 2
Download Bookmark Comment

Ariens 2000i Inverter Operator's Manual

Operation manual.
Hide thumbs
   
OPERATOR'S MANUAL
SPECIFICATIONS
ILLUSTRATIONS
Maximum Running Watt Rating............................... 3600 W
INVERTER PARALLEL KIT AUN9230PK
Maximum Starting Watt Rating ...............................4500 W
Fig. 1
Fig. 3
For use only with the following Inverter
PowerStroke PSi2000 Series
Output ..............................................................120 V / 30 A
Generators:
Ariens ARi2000 Series
APPLICATIONS
B
C
A
Ryobi RYi2200 Series
C
Gravely GVi2000 Series
You may use this product for the following purpose:
PowerStroke PSi2000 Series
 Link two inverter generators together for the sum of the
D
Ariens ARi2000 Series
two inverter wattage rating.
Gravely GVi2000 Series
C
B
CONNECTING THE PARALLEL KIT
D
D
See Figures 1 - 3.
E
The AUN9230PK parallel kit can be used to link any of the
WARNING!
A - 120 volt AC 30 amp receptacle (TT-30R) RV (prise de 120 v c.a. 30 a
following series of inverter generators: RYi2200, PSi2000,
[TT-30R] RV, receptáculo de 120 v c.a. 30 a [TT-30R] RV)
READ AND UNDERSTAND ALL INSTRUCTIONS.
ARi2000, or GVi2000.
B - 120 volt AC 30 amp (L5-30R) twist (120 v c.a. 30 a (L5-30R) rotation,
Failure to follow all instructions listed below may result
NOTE: Must use two of the same model inverter generators
120 v c.a. 30 a (L5-30R) fijación)
in electric shock, fire and/or serious injury.
together. Do not link different brands and models.
C - Parallel kit cables (câbles de l'ensemble parallèle, cables del equipo
 Turn off inverter generators according to the instructions
para funcionamiento)
D - Ground wire (câble de mise à la terre, cable de conexión a tierra)
included with your models.
WARNING!
E - Hanging bracket (dispositif d'ancrage, soporte de suspensión
NOTE: Do not connect or disconnect the parallel kit while
E
To reduce the risk of injury, user must read and
E
the inverter generators are running.
understand the operator's manual for their generator
Fig. 2
Ryobi RYi2200 Series
 Position inverter generators and parallel kit as shown in
A
and this instruction sheet. Ensure compatibility and fit
figure 2.
D
before using any accessory. Do not use an accessory if
A - Inverter parallel kit (ensemble en parallèle pour à inverseur, juego para
NOTE: Parallel kit may also be hung nearby, using
a part is damaged or missing. If you are not comfortable
conexión en paralelo de inversor)
hanging brackets. see figure 4.
performing any of the functions described in these
B - Ground terminal (borne de terre, ground terminal)
instructions, take your unit to an authorized service
C - Ground wire (-) (câble de mise à la terre,cable de conexión a tierra)
 Remove any load from the inverter generators.
D - Parallel kit terminals (parallel kit terminals, parallel kit terminals)
center.
 Connect the parallel kit cables to the parallel kit terminals
E - Parallel kit cables (parallel kit cables, parallel kit cables)
on the inverter generators.
 This product is for outdoor use only.
B
C
 Loosen screws on ground terminals on inverters. Attach a
Fig. 4
 Do not attach parallel kit while inverter generator are
ground wire to each inverter. Tighten securely.
running.
1/4"
 Turn on the inverter generators according to the instructions
 Do not get the product wet. Do not use if this product
included with your model.
is exposed to moisture.
 Connect devices to power/charge into appropriate
 Do not disassemble. This product has no user-
receptacles.
serviceable parts.
 When finished, turn off the inverter generators and
 As with all electrical devices, use caution when
disconnect the parallel kit.
plugging and unplugging this unit into an outlet or
HANGING THE PARALLEL KIT
plugging/unplugging other devices into this unit. Do
E
See Figure 4.
not force this unit into an outlet. Do not force plugs into
 Screws or nails for hanging the parallel kit should be
E
this unit.
4-1/2"
spaced 4-1/4 in. from center to center.
 If required, use only UL/ETL approved extension cords
A
 Mark the 4-1/4 in. measurement on a wall stud or other
with this product.
sturdy wood surface.
 If this product is used in a manner not specified by
A - Inverter parallel kit (ensemble en parallèle pour à inverseur, juego para
 Drill holes and insert the screws; tighten the screws se-
the manufacturer, the protection provided by this
conexión en paralelo de inversor)
curely into the wood. If using nails, the nail head should
equipment may be impaired.
B - Ground terminal (borne de terre, ground terminal)
be large enough to hold the parallel kit.
C - Ground wire (-) (câble de mise à la terre,cable de conexión a tierra)
 Do not overload the parallel kit. The kit can supply a
NOTE: There should be at least 5/8 in. of the screws or
D - Parallel kit terminals (terminaux de l'ensemble parallèle, paralelo a los
maximum of 30 amps at 120 V or 3600 watts depending
terminales)
nails protruding from the wood piece for hanging the
on the rating of the inverter generators.
E - Parallel kit cables (câbles de l'ensemble parallèle, cables del equipo
parallet kit.
 Do not parallel more than two inverter generators.
para funcionamiento)
 Hang the parallel kit on the screws or nails, making certain
 Save these instructions. Refer to them frequently and
it is secure.
use them to instruct others who may use this product.
If you loan someone this product, loan them these
CALIFORNIA PROPOSITION 65
instructions also.
WARNING:
This product may contain chemicals, including lead,
known to the State of California to cause cancer, birth
OWT INDUSTRIES, INC.
defects or other reproductive harm. Wash hands after
handling.
Highway 8, Pickens, SC 29671
990000108
1-866-340-3912
8-24-12 (REV:01)

   Related Manuals for Ariens 2000i Inverter

No related manuals

   Summary of Contents for Ariens 2000i Inverter

  • Page 1

    Fig. 3 For use only with the following Inverter PowerStroke PSi2000 Series Output ..............120 V / 30 A Generators: Ariens ARi2000 Series APPLICATIONS Ryobi RYi2200 Series Gravely GVi2000 Series You may use this product for the following purpose: PowerStroke PSi2000 Series  Link two inverter generators together for the sum of the...

  • Page 2

    PowerStroke PSi2000 Series PowerStroke serie PSi2000 usarse para conectar generadores inversores de las siguientes régime nominal des deux onduleurs. Ariens ARi2000 Series series: RYi2200, PSi2000, ARi2000 o GVi2000. Ariens serie ARi2000 BRANCHEMENT DE L’ENSEMBLE PARALLÈLE NOTA: deben usarse dos generadores inversores del mismo modelo.

Comments to this Manuals

Symbols: 0
Latest comments: