17 Fault finding
17.2 Fault Memory
The fault memory stores details of the five most recent
faults. To display the fault memory, proceed as follows;
•With the interface in 'normal' mode, press and hold the
'mode' button (
) for 10 seconds until a flashing '0'
appears.
• Press the 'mode' button again.
• The 5 fault memory screens are now available to be
viewed, memory 1 being the most recent. Within each
memory screen, 5 additional screens provide further
information to assist the installer/engineer.
No.
Memory screen type
1
Fault code
2
Burner phase
3
DHW temperature
4
CH flow temperature
5
Tank temperature
To cancel the fault memory mode proceed as follows;
• Press and hold the 'mode' button for 10 seconds until
the screen returns to the 'user' mode.
Instructions for Use, Installation and Servicing ecoMAX pro
Comments
Fault code 1 – 26 (see page 31 – 'Fault finding')
Working phase
No function
°C at time of fault
No function
31